Skip to content

nemi WAMS Node

nemi WAMS Node

Description

nemi WAMS Node is the wireless sensor node for data acquisition in i4M's Wide Area Monitoring System (nemi WAMS). It is designed for monitoring cracks, strains and temperatures. In addition to its integrated humidity and temperature (climate) sensor, it offers connection options for up to three external sensors with analog output: strain gauge full bridges, Pt100 / Pt1000 resistance thermometers or potentiometric displacement sensors.

nemi WAMS was developed for applications that do not require high data rates but large-area sensor coverage and long battery runtimes. This is made possible by i4M's own energy-efficient long-range radio technology nemi Link 868 in the 868 MHz frequency band. The node is powered by an integrated lithium primary cell with a battery life of approx. 5 years (one measured value transmitted every 20 minutes) and transmits its data to the nemi WAMS Bridge gateway.

nemi Link 868 vs. nemi Link 2400

nemi WAMS uses the radio technology nemi Link 868 (868 MHz, long range, low data rate). It is a separate network from nemi Link 2400 (2.4 GHz, high data rate). nemi WAMS Node transmits only to nemi Link 868 receivers such as the nemi WAMS Bridge.

Turnkey system — configured by i4M

nemi WAMS is delivered as a turnkey system: i4M configures the sensor nodes, the radio network, the gateway and the data transmission (cellular connection, MQTT server) for your application before delivery. The customer only has to install the components on site. This is different from nemi Link 2400, where the user can configure practically everything (radio channel, data rates, sampling rates, logging) themselves.

Key Features

  • Variety of connection options for external sensors (configuration selected at order)
  • Integrated humidity and temperature sensor
  • Completely wireless thanks to nemi Link 868 radio and integrated battery
  • More than 5 years of battery life
  • Transmission of raw data or pre-evaluated smart data (edge computing)
  • Data sampling every 1 to 20 minutes, alarm via SMS every 1 to 5 minutes
  • Robust, weatherproof IP67 housing

Typical Applications

Because no cabling is required, nemi WAMS enables easy installation even on large assets and structures.

  • Crack monitoring — crack width measurement on bridges and civil structures with potentiometric displacement sensors (configuration K03).
  • Strain monitoring — strain gauge full bridges on structures (configuration K01).
  • Climate monitoring — local temperature and humidity with the integrated climate sensor, e.g. on bridges.
  • Continuous temperature monitoring — e.g. on rolling bearings in large facilities with Pt100 / Pt1000 sensors (configuration K02).

Use case: monitoring of crack widths and local climate on a bridge


Technical Specifications

General

Parameter Value Unit
Dimensions (without antenna, connectors and retaining plate) 140 × 95.7 × 50.4 mm
Weight (with retaining plate) 510 g
Internal power supply Lithium primary cell (type Saft 14500) —
Battery life (one measured value transmitted per 20 minutes) approx. 5 years
Operating temperature −20 to 60 °C
Onboard MCU (usable for edge computing) 48 MHz 32-bit MCU, 256 KB Flash, 32 KB RAM —
Housing protection class IP67 —

Dimensions of nemi WAMS Node

(All dimensions in mm)

Inputs for External Sensors with Analog Output

Parameter Value Unit
Connectable sensors Wheatstone full bridges (e.g. strain gauges) or potentiometric sensors; resistance sensors with constant current supply (e.g. Pt100 / Pt1000); potentiometric displacement sensors —
Number of channels max. 3 —
Max. sampling rate (for internal calculations only, no live transmission) 19,200 (1 channel active) / 1,000 (3 channels active) Hz
Selectable signal gains 128 / 64 / 32 / 16 / 8 / 4 / 2 / 1 —
Max. input voltage measuring range (gain 1) 0–2.5 V
Input impedance > 1 MΩ
Possible feed currents 1,000 / 750 / 500 / 250 / 100 / 50 µA
Sensor supply voltage 2.5 V
Signal resolution 24 bit
Inaccuracy << 1 %

Integrated Climate Sensor (measuring to the outside)

Parameter Value Unit
Sampling rate 1 Hz
Temperature measuring range −40 to 125 °C
Temperature resolution 0.015 °C
Temperature inaccuracy ± 0.2 °C
Humidity measuring range 0–100 % rH
Humidity resolution 0.02 % rH
Humidity inaccuracy ± 1.8 % rH
Parameter Value Unit
Frequency band 868 MHz ISM band —
Topology Star (gateway / receiver module) —
Radio range up to 1,000 m
Max. sensor nodes per gateway 30 —
Max. sum sampling rate (24 bit per sample) approx. 200 Hz
Time synchronization deviation 100 ms
Data sampling / transmission interval every 1 to 20 minutes —
Alarm via SMS every 1 to 5 minutes —
Compatible receivers nemi WAMS Bridge —

Mounting & Connections

Mechanical Mounting

nemi WAMS Node is mounted with a retaining plate (mounting material for structural installations is available on request). According to the dimension drawing, the plate has two Ø 9 mm mounting holes with a spacing of 120 mm. The IP67 housing is suitable for outdoor installation on structures.

Configuration Options for External Sensors

nemi WAMS Node offers three configuration options for external sensors with analog output:

  • K01 — up to 3 Wheatstone sensors in full-bridge circuit, e.g. strain gauges
  • K02 — up to 3 Pt100 / Pt1000 resistance thermometers or other resistance sensors with constant current supply
  • K03 — up to 3 potentiometric sensors, e.g. displacement sensors

Configuration options K01–K03 of nemi WAMS Node

Configuration is fixed at order time

The configuration of the analog inputs must be defined and specified before delivery. Subsequent modification is only possible by i4M technologies.

Pin Assignment

Each sensor connector of nemi WAMS Node has 4 pins for connecting an external sensor with analog output. The pin assignment depends on the configuration option.

Configuration K01 — Wheatstone sensors (full bridge)

Pin assignment of configuration K01 (Wheatstone full bridge)

Pin Signal
1 GND
2 − (measuring signal)
3 + (measuring signal)
4 VS (supply voltage)

As an alternative to Wheatstone sensors, configuration K01 can also be used to measure voltages: up to three voltages with a measuring range of 0–2.5 V can be measured. In this case, pin 1 and pin 4 remain free and the measuring voltage Vm is measured between pin 2 and pin 3.

Configuration K02 — resistance thermometers (e.g. Pt100 / Pt1000)

Pin assignment of configuration K02 (resistance thermometer)

Pin Signal
1 Iref (constant current ICONST)
3 − (compensation current ICOMP)
4 GND

Configuration K03 — potentiometric displacement sensors

Pin assignment of configuration K03 (potentiometric displacement sensor)

Pin Signal
1 VS (supply voltage)
3 Vout (output voltage)
4 GND

Legend: Vm = measuring voltage · Iref = reference current · GND = ground · Vout = output voltage · ICONST = constant current · VS = supply voltage · ICOMP = compensation current

Power Supply

nemi WAMS Node is powered by an integrated lithium primary cell (type Saft 14500). With one measured value transmitted every 20 minutes, the battery life is approx. 5 years.


Integration

nemi WAMS Node transmits its data via nemi Link 868 to the nemi WAMS Bridge gateway, which forwards it via 4G NB-IoT cellular radio as MQTT data streams to a server.

nemi WAMS Node(s)  (up to 30 per gateway)
    │  nemi Link 868 (868 MHz, up to 1,000 m)
    ▼
nemi WAMS Bridge
    │  4G NB-IoT cellular
    ▼
MQTT broker / server → database → dashboard / software

Data Analysis

On request, i4M supports data analysis. Analyses can be performed directly in the sensor node or in the gateway by edge analytics as well as on the server or measuring computer. Edge analytics reduces the transmitted data to the essentials ("smart data"), which reduces storage space and increases battery runtimes. In addition to existing algorithms, i4M creates individual evaluation scripts on request.

The data stays in your own IT ecosystem. Alternatively, nemione® cloud solutions hosted in the European Union are available.


Product Variants

Variant Sensor inputs Order code
nemi WAMS Node K01 Up to 3 Wheatstone full bridges (e.g. strain gauges) or up to 3 voltages 0–2.5 V K01
nemi WAMS Node K02 Up to 3 Pt100 / Pt1000 resistance thermometers or other resistance sensors with constant current supply K02
nemi WAMS Node K03 Up to 3 potentiometric sensors, e.g. displacement sensors K03

Ordering option: nemi WAMS Node Kxx (xx = configuration option). The integrated climate sensor is included in all variants.


FAQ

Do I have to configure the radio network or the gateway myself? No. nemi WAMS is delivered as a turnkey system: i4M configures sensor nodes, radio network, gateway and data transmission for your application. You only install the components on site.

Which sensors can be connected to nemi WAMS Node? Up to three external sensors with analog output of one type: Wheatstone full bridges such as strain gauges (K01), Pt100 / Pt1000 resistance thermometers or other resistance sensors with constant current supply (K02), or potentiometric sensors such as displacement sensors (K03). With K01, voltages of 0–2.5 V can also be measured.

Can I change the sensor configuration after delivery? No. The configuration of the analog inputs must be specified before delivery. Subsequent modification is only possible by i4M technologies.

How long does the battery last? Approx. 5 years with transmission of one measured value every 20 minutes. The node is powered by a lithium primary cell (type Saft 14500).

How often are measured values acquired and transmitted? Data is sampled every 1 to 20 minutes; alarms can be sent via SMS every 1 to 5 minutes. Internally, the analog inputs can be sampled at up to 19.2 kHz (1 channel) or 1 kHz (3 channels) for internal calculations; these high-rate samples are not transmitted live.

Does nemi WAMS Node measure ambient conditions? Yes. An integrated climate sensor measures ambient temperature (−40 to 125 °C, ± 0.2 °C) and relative humidity (0–100 % rH, ± 1.8 % rH).

Which receiver do I need? The nemi WAMS Bridge (nemi Link 868 gateway). nemi Link 2400 receivers such as nemi Connect, nemi Log or nemi EdgeBase are not compatible.

What is the radio range? Up to 1,000 m to the nemi WAMS Bridge. Actual range depends on line of sight, obstructions and antenna placement and must be validated on site.