nemi DAQ

nemi DAQ

Description

nemi DAQ is a compact, wireless, multi-sensor data acquisition and telemetry module — in short, a wireless strain gauge amplifier with versatile connection options. It accepts a wide variety of external sensors — Wheatstone / strain gauge full bridges, potentiometers, resistance temperature sensors (Pt100 / Pt1000), thermocouples (e.g. Type K), thermistors and 0–10 V analog sensors — alongside up to six switching digital inputs, and adds an integrated 9-DoF inertial measurement unit (accelerometer, gyroscope, magnetometer) plus an internal temperature sensor. All measurement data is transmitted live and wirelessly over i4M's proprietary nemi Link 2400 radio technology in the 2.4 GHz band — all in a housing of 85 × 72 × 19 mm and approximately 150 g.

The nemi DAQ is built for applications where cabling is difficult or impossible: rotating machinery, moving structures, and remote monitoring sites. Typical measurands are strain, force, moments and torque, distances (e.g. cracks), temperatures and switching states. Thanks to the integrated IMU, the spatial orientation is captured at the same time, which can save additional rotation-angle sensors, particularly in rotating applications.

Its internal lithium-ion battery delivers more than 14 days of continuous operation at 100 Hz, and a wide-range voltage input (5–30 V DC) enables permanent installation with cabled power supply or external battery packs. An onboard 64 MHz 32-bit microcontroller supports edge computing so that pre-processed "smart data" can be transmitted instead of raw samples, reducing radio bandwidth and extending battery life. Edge computing can be realized upon request in bilateral development projects.

The nemi DAQ nano is the PCB-only miniaturized OEM variant of the same platform with two analog and two digital inputs. It shares the same radio protocol, firmware architecture, and software toolchain as the nemi DAQ, making it suitable for integration into tight installations such as rotating components or embedded sensor bodies. For a robust, weather-resistant housed solution based on the nano, see nemi Struct.

Data from nemi DAQ nodes is received by a compatible receiver module — nemi Connect (USB receiver for PC or Gantner Q.Station), nemi Log (compact SD-logger with cellular option), or nemi EdgeBase (autonomous field gateway with 4G, edge computing, and local SSD storage). All three receivers share the same star-topology radio architecture: one receiver per radio channel, up to eight sensor nodes per channel. The receiver handles data access, storage, downstream integration and time synchronization to host or external time sources.


Typical Applications

  • Portable test measurements — rapid, cable-free installation for short-duration tests in locations where cabling is impractical.
  • Torsion / torque and load measurements on rotating or moving components — e.g. in drive trains. No slip rings or cables are required because the module is fully self-contained.
  • Long-term load measurements on rotor shafts — for example of wind turbines; with wide-range voltage input for permanent installations.
  • Strain gauge measurements on vehicles and machines — for example on streetcar wheels, motor vehicle chassis springs or lift bridge drives.
  • Structural health monitoring (SHM) — bridges, towers, suspended structures and other civil engineering assets.
  • Dynamic monitoring — for example of roller coasters.
Application Notes
Strain gauge / Wheatstone bridge measurements Primary use case; up to 3 bridge channels per nemi DAQ with 24-bit resolution and up to 6.4 kHz of sampling rate
Torque and bending on rotating shafts Rotates with the shaft and transmits live and low-latency data wirelessly, avoiding slip rings
Potentiometric displacement and position sensors (e.g. crack monitoring) Reference-voltage input with gain 1; verify impedance compatibility
Pt100 / Pt1000 temperature sensing Constant-current excitation (500 µA); requires a reference-current configuration (K05 or K11)
Thermocouple (e.g. Type K) and thermistor sensing Connected as reference-voltage sensors with appropriate signal conditioning
0–10 V analog sensors Wind speed, force transducers, process transmitters; requires a 0–10 V configuration (attenuator)
Acceleration, vibration, and inclination (IMU) Integrated 9-DoF IMU; tilt accuracy ~0.1° at ±2 g range
Digital switching sensors (proximity, level, distance, rotation) Up to 6 digital inputs at 2,000 Hz fixed rate; TTL / NPN sensors
Geophone / seismic velocity sensors Geophones connect directly to the high-impedance analog inputs; add a shunt resistor externally to set damping impedance

Technical Specifications

General

Parameter Value Unit
Dimensions (without antenna and connectors) 85 × 72 × 19 mm
Footprint including connectors 104 × 71.7 mm
Weight approx. 150 g
Housing protection rating IP 41 (weather-resistant box on request) —
Operating temperature range −20 to 60 °C
Onboard MCU, usable for edge computing 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, various hardware crypto features —

Dimensions of nemi DAQ (all dimensions in mm)

Power Supply

Parameter Value Unit
Internal battery Lithium-ion, 1 cell —
Runtime at 100 Hz (full battery) > 14 days; up to several weeks depending on configuration —
Charging time (0–100 %) approx. 5 h
External power supply / charging (USB-C) 5 V
Wide-range voltage input (pins 15 / 16) 5–30 DC V
Low-power option: direct supply input (factory option) 3.3–5 DC V

External Analog Inputs

Parameter Value Unit
Number of analog channels max. 3 —
Connectable sensor types Reference-voltage sensors (Wheatstone / strain gauge full bridges, potentiometer sensors, thermocouples e.g. Type K, thermistors); reference-current sensors (Pt100 / Pt1000); analog sensors with 0–10 V output —
Max. sampling rate (with active channels) 6,400 (1 channel); 1,944 (2 channels); 1,296 (3 channels) Hz
Signal bandwidth (−3 dB) sampling rate × 0.23 Hz
Sampling rate stability (full temperature range) ± 50 ppm
Signal resolution 24 bit
Analog measurement error << 0.1 (with automatic self-calibration) %
Selectable signal gains 1 / 4 / 8 / 16 / 32 / 64 / 128 —
Wheatstone bridge supply voltage 2.5 V
Constant-current feed current (Pt100 / Pt1000) 500 µA

External Digital Inputs

Parameter Value Unit
Number of digital channels max. 6 —
Digital input signal level (high) 3.3–24 V
Sampling rate 2,000 Hz
Sensor switching voltage, high level 3.3–24 (selectable in software) V
Sensor switching voltage, low level < 2 V
Compatible sensors Switching displacement, distance, level or rotation-angle sensors; TTL / NPN sensors —

Integrated 9-DoF IMU (ACC / GYR / MAG)

Parameter Value Unit
Sensor type 9-DoF MEMS IMU: 3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer —
ACC / GYR sampling rates 3,332 / 1,666 / 833 / 416 / 208 / 104 / 52 Hz
MAG sampling rate always 1/8 of the ACC / GYR rate —
Signal resolution 16 bit
ACC ranges ± 16 / 8 / 4 / 2 g
GYR ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
MAG ranges ± 16 / 12 / 8 / 4 Gauss

Internal Temperature Sensor

Parameter Value Unit
Measuring range −20 to 60 °C
Parameter Value
Frequency band 2.4 GHz (proprietary protocol, not Wi-Fi / Bluetooth)
Topology Star (one receiver per channel)
Max. sensor nodes per channel 8
Radio modes 2 Mbit/s / 1 Mbit/s / 500 kbit/s / 125 kbit/s
Range up to 350 m (see Range Considerations)
Compatible receivers nemi Connect, nemi Log (+ cellular), nemi EdgeBase

First Commissioning

Required Hardware and Software

Item Purpose
nemi DAQ with the ordered hardware configuration (K option) Sensor node
nemi Connect / nemi EdgeBase / nemi Log Receiver
USB-C cable (data-capable, not charge-only) USB configuration and charging
nemi Sensor Config v2.1 or later Radio and node configuration via USB
nemi Studio v1.1 or later or nemi Studio Web App Wireless measurement settings, live display and CSV recording

Download links for the software tools are provided to customers (the software is not publicly available). The nemi Studio Web App runs in the browser and needs no installation.

Step 1 — Verify the Hardware Configuration (K Option)

The input configuration of the nemi DAQ is defined in hardware before delivery and is specified by the order code nemi DAQ Kxx. It determines which input type is wired to which channel and whether channel 3 is an analog input or four additional digital inputs. Subsequent modification is only possible by i4M technologies. Confirm the K code on the label or in the delivery documentation before wiring any sensors.

Configuration options of nemi DAQ

K option Channel 1 Channel 2 Channel 3 Digital inputs (total)
K01 Reference voltage Reference voltage Reference voltage 2
K02 Reference voltage Reference voltage 0–10 V 2
K03 Reference voltage 0–10 V 0–10 V 2
K04 0–10 V 0–10 V 0–10 V 2
K05 Reference current Reference current Reference current 2
K08 Reference voltage Reference voltage 4 × digital input 6
K09 Reference voltage 0–10 V 4 × digital input 6
K10 0–10 V 0–10 V 4 × digital input 6
K11 Reference current Reference current 4 × digital input 6

Reference voltage = Wheatstone / strain gauge full bridges, potentiometer sensors, thermocouples, thermistors. Reference current = Pt100 / Pt1000 resistance thermometers.

No mixing of reference-voltage and reference-current sensors

A combination of reference-voltage sensors (e.g. strain gauges) and reference-current sensors (Pt100 / Pt1000) on one nemi DAQ is not possible. Decide before ordering, or use two nemi DAQ units.

Step 2 — Wire the External Sensors

See Mounting & Connections for the pin assignment. Key points:

  • Always use the pin assignment of your specific K option.
  • Disable unused channels in software (gain = off) or short the input terminals. A floating high-impedance input induces noise into active channels, especially at high gain settings.
  • Keep sensor cables as short as possible to minimize parasitic capacitance effects.

Step 3 — Power / Charge the Module

Connect the nemi DAQ via USB-C to a PC or USB charger before first use. The solid red LED indicates charging is in progress; the red LED turning off indicates a full battery. A full charge from 0 % takes approximately 5 hours but is not needed for first tests. If the module will run from external power, connect the wide-range input (pin 15 "+", pin 16 GND) only to a DC supply within 5–30 V.

If the module is powered from a USB power supply without grounding, make sure that the nemi DAQ is additionally grounded (see Power Connections).

Step 4 — Configure the Radio Parameters via USB

Radio parameters (channel, radio mode, node number, maximum nodes) are persistent settings written with nemi Sensor Config over USB. The procedure is the same as for all nemi Link 2400 sensor nodes (see nemi G+ for screenshots):

  1. Launch nemi Sensor Config and connect the nemi DAQ to the PC with a data-capable USB-C cable.
  2. When the node starts, the LED cycles white → green → red → blue (restart), then shows solid green + flashing yellow (USB detected; waiting for COM port).
  3. nemi Sensor Config shows the new nemi sensor node and automatically selects its COM port. Click Connect COM-Port within approximately 10 seconds; otherwise the node enters radio transmission mode. The LED changes to solid green + flashing blue (COM port open; awaiting settings).
  4. Enter the radio parameters from the table below and click Set nemi Link Parameters.
  5. The node prints its new radio parameters in the console and the COM port connection is closed automatically. After 10 s the node starts radio transmission with the new parameters.

Recommended first-test radio settings:

Parameter Recommended value Notes
nemi Link 2400 Mode 2 Mbit/s Highest throughput; adequate range for bench tests
nemi Link 2400 Node Count 1 or 3 Increase to 8 nodes if needed, but the maximum sampling rate per node is reduced
nemi Link 2400 Channel 0 (other preferred channels are 25, 50, 75) Default and a good choice for most installations
nemi Link 2400 Node Number 1 Unique per node on the same channel. Assign 2, 3, … for additional nodes

For sites with multiple independent radio networks, use channels separated by at least 10 (e.g. channels 0, 25, 50, 75). Channel 10 also works, but may be slightly more exposed to Wi-Fi interference than channel 0. For more information regarding the radio network see nemi Link 2400.

Step 5 — Set Up the Receiver and Verify Data

With nemi Connect (or a nemi Log used as USB receiver):

  1. Launch nemi Studio or open the nemi Studio Web App in Chrome or Edge.
  2. Plug the nemi Connect into a USB port of the PC. The nemi Connect is detected and its COM port is selected automatically.
  3. Click Connect COM-Port, set the radio settings (data rate, nodes per channel, channel) matching the node, select the module type nemi DAQ for the node and click Start Receiver.
  4. Power on the nemi DAQ without connected USB cable (or leave it on external supply). Within a few seconds live data should appear. Check the signal strength and latency indicators; low signal strength together with increasing latency or missing samples indicates insufficient range.
  5. Set the analog sampling rate (AF ODR), the gain per channel, the IMU rate and ranges and the digital input level (GPIO) wirelessly and click Update Node Settings. A node may take up to approx. one minute to apply new settings.
  6. Select the display unit of the analog channels (Y Axis Unit: mV/V, V, °C for Pt100 / Pt1000, or 0–10 V).
  7. Apply a known load or excitation to verify signal polarity and magnitude, then start a short CSV recording to verify the data before mounting the module at its final location.

With nemi Log: The nemi Log is a standalone data logger with cellular option that requires no PC during operation. Initial configuration is done via CSV files. Once the nemi Log is configured and powered, the nemi DAQ pairs automatically when channel and radio mode match.

With nemi EdgeBase: The nemi EdgeBase is a standalone field gateway requiring no PC during operation. Initial configuration is done via YAML files. Once the nemi EdgeBase is configured and powered, the nemi DAQ pairs automatically when channel and radio mode match. Use EdgeBase logging_mode 6 to connect nemi Studio or the nemi Studio Web App to the nemi EdgeBase over the network to check live data.

First Data Transmission — Checklist

  1. Confirm the receiver is connected, powered and on the same channel, radio mode and node count as the node.
  2. Confirm each node has a unique node number on the shared channel.
  3. Confirm the analog channels show the expected baseline (near zero for unstrained gauges; a plausible temperature for Pt100 / Pt1000).
  4. Verify live data, signal strength and latency in nemi Studio or the nemi Studio Web App.
  5. Test at the intended installation location before final mounting — rule out radio issues before the module is installed in an inaccessible location.

LED Status Codes

LED pattern Meaning
Rapid flash: white → green → red → blue Sensor node restart
Solid red Battery charging (see note below)
Red no longer continuously lit Battery fully charged
Solid green + flashing yellow USB data connection detected; waiting for COM port to open
Solid green + flashing blue COM port open; waiting for RF parameters or settings
Short red flashes (~2 s) Actively sampling and transmitting measurement data
Short green flashes every 10 s (~1 s) Sleep mode
Short blue flashes (~1 s) Time synchronization with wireless network
Green LED on temporarily or continuously (in wireless mode) Internal ring buffer 80 % full — data cannot be transmitted fast enough; risk of data loss

The internal battery is recharged both via USB-C and via the wide-range input (DC IN). To save power when the module is supplied by an external battery pack, the charge LED only shows the charging status when charging via USB-C, not when connected to DC IN.

Range Considerations

nemi Link 2400 operates at 2.4 GHz. Typical ranges by radio mode:

Radio mode Typical range (in buildings – in urban environment)
2 Mbit/s 20 – 50 m
1 Mbit/s 50 – 125 m
500 kbit/s 90 – 225 m
125 kbit/s 140 – 350 m

Range is strongly affected by antenna orientation, metal shielding and obstructions. Mount the module at the intended position, place the receiver antenna as it will be used in service, and test the actual sampling rate and node count on site.


Mounting & Connections

Pin Assignment

The nemi DAQ has 16 pins on two screw terminals. 14 pins can be used to connect external sensors; the other two pins are used for the wide-range voltage input.

Pin assignment of the analog and digital inputs of nemi DAQ

Pin(s) Function
1–4 Channel 1: analog input (reference voltage, reference current or 0–10 V)
5–8 Channel 2: analog input (reference voltage, reference current or 0–10 V)
9–12 Channel 3: analog input or four digital inputs DIN 3–6 (depending on K option)
13 DIN 2 (digital input, 3.3–24 V)
14 DIN 1 (digital input, 3.3–24 V)
15 VIN+ — wide-range voltage input 5–30 V (3.3–5 V on request)
16 GND

Pin signal definitions per channel and input type:

Pin (Ch 1 / Ch 2 / Ch 3) Reference voltage Reference current 0–10 V Digital (Ch 3 only)
1 / 5 / 9 VS (2.5 V supply) NC VIN+ (sensor supply from DC IN) DIN 6
2 / 6 / 10 + + (ICONST) + DIN 5
3 / 7 / 11 − − (ICOMP) − DIN 4
4 / 8 / 12 GND GND GND DIN 3

GND = ground; NC = not connected; VS = supply voltage (2.5 V); VIN+ = positive input voltage (DC IN); DIN = digital input; ICONST = constant current; ICOMP = compensation current.

Example K01 — channel 1 + 2: strain gauge full bridges, channel 3: potentiometer, DIN 1–2: digital inputs:

Example pin assignment for configuration K01

Example K11 — channel 1 + 2: Pt100 / Pt1000 (3-wire), DIN 1–6: digital inputs:

Example pin assignment for configuration K11

Wiring Notes from Field Experience

  • Unused channels: Disable unused channels in software (gain = off) or short the input terminals. A floating input induces noise, especially at high gain (128×).
  • Potentiometer input impedance: Verify the wiper impedance is low relative to the DAQ input impedance. A 2 kΩ potentiometer is generally safe; very high-impedance dividers can cause loading issues.
  • Cable length: Long cables add parasitic capacitance, which causes settling artefacts in Ultra Low Power (pulsed) excitation modes. Keep cables shorter than approximately 5 m when using ULP modes. Use High-Res mode if longer cables are unavoidable.
  • 0–10 V sensors: Connect the sensor GND to the GND pin of the channel. When 0–10 V channels are used, the DC IN voltage is routed to the sensor supply pins (VIN+), so 0–10 V sensors can be supplied from the nemi DAQ if the DAQ is powered by a supply that meets the sensors' requirements. In sleep mode the sensor supply is switched off to save power.

Power Connections

nemi DAQ can be powered in three ways:

  1. Internal rechargeable battery — suitable for temporary installations and battery-powered monitoring.
  2. 5 V USB-C — for charging and USB configuration. The module can also operate while connected.
  3. 5–30 V DC wide-range voltage input (pin 15 "+", pin 16 GND) — for permanent installations, e.g. with a power supply, an external battery pack or a solar charge controller. As a low-power factory option, a 3.3–5 V input connected directly to the circuit is available, e.g. for a lithium primary cell (maximum efficiency, no voltage converter).

The internal battery is recharged through USB-C and DC IN; it can therefore serve as a buffer for intermittent external power supplies. Observe supply polarity.

Grounding: Standard USB power supplies have no protective earth connection, causing the measurement circuitry to float relative to earth. If the module is powered from a USB power supply without grounding, additionally ground the nemi DAQ (GND pin). This is especially important in environments with variable-frequency drives or heavy electrical equipment.

Physical Mounting

The datasheet defines no specific mounting interface. Depending on the installation, the module can be mounted with screws through the housing end caps, with adhesive or with magnetic fasteners (temporary installations on steel structures). Mounting material (e.g. screws, adhesive, magnets) is not included; it is only supplied as an option if ordered. Use strain relief for all sensor cables, especially on rotating parts.

The nemi DAQ is rated IP 41 — protected against solid objects > 1 mm and dripping water (vertical). For outdoor permanent installations in rain or splash conditions, mount it in an IP-rated enclosure. A weather-resistant box is available on request; alternatively use nemi Struct.

Antenna

The nemi DAQ uses an external, screw-on rod antenna. Avoid mounting the antenna directly against metal surfaces. For rotating or shielded installations, place the receiver where the radio path is as clear as possible and test with the final enclosure closed.


Detailed Configuration

Configuration is split into three layers:

  • Hardware configuration — K option (input types, channel 3 analog vs. digital), defined before delivery.
  • Persistent radio settings — written via nemi Sensor Config over USB (channel, radio mode, node number, max nodes).
  • Runtime measurement settings — set wirelessly via nemi Studio, nemi Studio Web App, nemi EdgeBase YAML files or nemi Log configuration CSVs (active channels, sampling rates, gains, IMU ranges, digital input levels).

Configuration Tools Reference

Tool Connection Configures
nemi Sensor Config v2.1+ USB (USB-C) Radio channel, radio mode, node number, max nodes per channel
nemi Studio via nemi Connect or nemi EdgeBase Mode (sleep / continuous / intermittent), AF ODR, gain per channel, IMU ODR and ranges, GPIO level, zero and scaling
nemi Studio Web App via nemi Connect or nemi EdgeBase Radio network, sampling rates, measuring ranges, live display and CSV recording
nemi Link 2400 Radio Channel Calculator Online tool (replaces the former Excel configuration tool) Validates that sampling rates fit within channel bandwidth for given radio mode and node count
nemi EdgeBase YAML config files VPN / FTP Sampling rates, gains, trigger parameters, logging intervals, MQTT settings, sleep/wake schedules
nemi Log CSV config files SD card / FTP Sampling rates, gains, trigger parameters, logging intervals, sleep/wake schedules

Analog Channels: Sampling Rate

The live radio-transmitted sampling rate applies to all active analog channels and depends on the number of active channels: the more channels are active, the lower the sampling rate. The active channels can be freely selected in software. For the highest sampling rate, activate only one channel.

ODR setting Mode 1 channel (Hz) 2 channels (Hz) 3 channels (Hz)
0 — AD off AD off AD off
1 High Res — 1,944 1,296
2 High Res 6,400 1,074 716
3 High Res 4,800 742 495
4 High Res 3,200 567 378
5 High Res 2,400 459 306
6 High Res 1,600 385 257
7 High Res 800 332 221
8 High Res 400 291 194
9 High Res 200 235 156
10 High Res 100 196 131
11 Ultra Low Power 100 100 100
12 Ultra Low Power 75 75 75
13 Ultra Low Power 50 50 50
14 Ultra Low Power 25 25 25
15 Ultra Low Power 1 1 1

The −3 dB signal bandwidth equals the sampling rate multiplied by 0.23: 1,472 Hz at 6,400 Hz sampling rate, 23 Hz at 100 Hz. Choose the sampling rate so that the signal bandwidth of interest lies well below this cutoff.

  • High Res (ODR 1–10): continuous bridge excitation; suitable for all cable lengths; higher power consumption. Use these modes for commissioning.
  • Ultra Low Power (ODR 11–15): pulsed bridge excitation; extended battery life; avoid with cables longer than ~5 m due to settling artefacts (see Troubleshooting). If a bridge channel shows short spikes in Ultra Low Power mode, repeat the test in High Res mode — if the spikes disappear, the cause is excitation settling, not a sensor fault.

Analog Channels: Gain and Measuring Range

Channel 4 / CH_4

nemi DAQ has up to three analog channels. i4M also builds customer-specific telemetry modules with four analog channels. In all software (nemi Studio, nemi Studio Web App, nemi EdgeBase, nemi Log) the gain of channel 4 is therefore always set equal to the gain of channel 3 (setting Ch. 3/4 Gain / ad_ch_3_4_gain). The data field CH_4 only carries data with such four-channel modules.

The signal gain is configured separately for each channel. With gain 1, the measuring range of reference-voltage sensors is 1,000 mV/V, which corresponds to 0–2.5 V at the 2.5 V supply voltage. With a Pt100 reference-current sensor the absolute measuring range is 0–249 mV. In a 0–10 V configuration an attenuator extends the input range to 0–10 V.

Gain setting Amplification Reference voltage (mV/V) Reference voltage, absolute (mV) Reference current, absolute (mV) Pt100 range (°C) Pt1000 range (°C) 0–10 V input (V)
0 Channel off — — — — — —
1 1 1,000.00 2,500.00 249 > 850 400 10.00
2 4 250.00 625.00 62.25 > 850 — 2.50
3 8 125.00 312.50 31.13 590 — 1.25
4 16 62.50 156.25 15.56 145 — 0.63
5 32 31.25 78.13 7.78 −60 — 0.31
6 64 15.63 39.06 3.89 −155 — 0.16
7 128 7.81 19.53 1.95 −200 — 0.08

Choose the gain that places the expected signal in the upper 50–80 % of the measuring range. An unnecessarily high gain can saturate the input; too low a gain wastes ADC resolution. If the expected signal is unknown, start with a conservative (low) gain and increase it after observing a known load. For Pt100 sensors, gain setting 3 (8×) is a practical starting point.

IMU Configuration

The IMU sampling rate is configured independently of the analog front end. ACC and GYR share the selected rate; the MAG always runs at 1/8 of the ACC / GYR rate.

IMU ODR setting ACC / GYR (Hz) MAG (Hz)
0 IMU off IMU off
1 52 7
2 104 13
3 208 26
4 416 52
5 833 104
6 1,666 208
7 3,332 416
Sensor Selectable ranges Selection guidance
ACC ±2 / ±4 / ±8 / ±16 g ±2 g for tilt monitoring (dynamic inclination accuracy approx. 0.1° at 16-bit resolution)
GYR ±125 / ±250 / ±500 / ±1,000 / ±2,000 / ±4,000 °/s Select above the expected peak rotation rate (4,000 °/s ≈ 666 rpm)
MAG ±4 / ±8 / ±12 / ±16 Gauss Enable only when heading information is required

For rotation-angle measurement on shafts with nemi Studio, use a high IMU rate (e.g. 3,332 Hz) and a gyroscope range matching the speed.

Digital Input (DIN) Configuration

The digital inputs are sampled at a fixed 2,000 Hz. The high level of the digital inputs is selected in software (nemi Studio setting GPIO: off, 5 V, 12 V, 24 V); the low level must be below 2 V. Signal levels from 3.3 V to 24 V are supported; the 5 V setting is also used for 3.3 V signals, as the high level threshold is the same.

Channel 3 (pins 9–12) is either one analog input or four additional digital inputs. This is defined by the K option in hardware — it cannot be changed in software.

Radio Mode, Channel and Node Configuration

Both the sensor node and the receiver must use the same radio mode, channel and node count. A mismatch produces no error message — the node simply does not appear.

Radio mode Parameter value (rf_Speed) Notes
2 Mbit/s (HS) 1 Maximum throughput; shortest range
1 Mbit/s (HS) 2 Good balance of throughput and range
500 kbit/s (XR) 3 Extended range; lower throughput
125 kbit/s (XR) 4 Longest range; lowest throughput
  • Up to 8 sensor nodes can share one channel (node count 1, 3 or 8).
  • Use channels 0, 25, 50 or 75 for up to four parallel networks; keep a spacing of at least 10 between independent networks.
  • Verify every planned combination of nodes, sampling rates and radio mode with the nemi Link 2400 Radio Channel Calculator.

0–10 V Conversion Factor

When channels are hardware-configured for 0–10 V input, an internal attenuator divides the signal before the ADC. The raw output remains in mV/V; the physical voltage is recovered by:

U_physical [V] = ADC_value [mV/V] × 2.5 V × 8.647058824 / 1000

This factor applies to all series nemi DAQ units delivered from 2023 onward. nemi Studio applies it automatically when the display unit 0 - 10 V is selected. An older factor (10.09090909) was used in pre-series prototype units and must not be applied to production hardware.

Common Configuration Patterns

Maximum-rate single-channel acquisition: Activate 1 analog channel, ODR setting 2 → 6,400 Hz. Disable the IMU or run it at a low rate (52 Hz) to avoid radio bandwidth saturation. Use radio mode 2 Mbit/s.

Long-term SHM at low power: 2–3 analog channels at ODR 13 (50 Hz ULP), IMU at 52 Hz, radio mode 500 kbit/s. Runtime of several weeks on battery.

MQTT dashboard at 10 Hz publish rate: With 2 active analog channels, use at least ODR 7 (332 Hz) to ensure at least one data packet per publish interval. See Integration.

Time Synchronization

Within one nemi Link 2400 wireless network, the nemi DAQ clock is synchronized to the receiver module. The synchronization accuracy within the wireless sensor network is ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long, and the accuracy decreases.

The receiver then handles its own downstream synchronization to the host system. For example, nemi EdgeBase uses NTP or GNSS; nemi Log uses the internal RTC or GNSS; nemi Connect with nemi Studio follows the host computer clock. This second-stage synchronization is documented with the respective receiver product.


Integration

nemi DAQ itself communicates only via nemi Link 2400 radio to a receiver. All external integration happens at the receiver level:

Receiver Best for Data access
nemi Connect PC-based live testing and ad-hoc measurements with nemi Studio or nemi Studio Web App, CSV logging, custom USB integration with the nemi Connect Python API, Gantner Q.Station USB virtual COM port
nemi Log Compact local medium-term standalone logging nemi Log .bin files with Python decoder
nemi EdgeBase Long-term standalone field monitoring, MQTT, FTP, LTE/VPN, edge computing .bin.bz2 files via Ethernet, LTE, OpenVPN, FTP; MQTT(S) streams

Integration Architecture

nemi DAQ / nemi DAQ nano
    │  nemi Link 2400 (2.4 GHz wireless)
    ▼
Receiver module
    ├── nemi Connect → USB → PC (nemi Studio / nemi Studio Web App / Python API / Q.Station)
    ├── nemi Log → SD card / LTE Cat M or NB-IoT with cellular option
    └── nemi EdgeBase → Ethernet / LTE / OpenVPN
              ├── MQTT broker  (aggregated values) → Database → Dashboard (e.g. Grafana)
              └── FTP server   (raw compressed binary files) → Python decoder → pandas DataFrames

CSV Recording (nemi Studio)

nemi Studio writes semicolon-separated CSV files per node. For the nemi DAQ these are:

File Content
<datetime>_<node>_telemetry_data.csv Analog channels in the selected unit (incl. zero and scaling)
<datetime>_<node>_din_data.csv Digital inputs
<datetime>_<node>_imu_data.csv IMU (ACC / GYR / MAG), temperature, battery voltage, RSSI; optionally angle columns

Each sample carries an ASCII timestamp, a UNIX timestamp and a time counter. See nemi Studio for details.

Python API (via nemi Connect)

nemi Connect presents a virtual COM port (USB CDC ACM). After the port is opened, the receiver expects its configuration and then streams the measurement data as COBS-encoded binary messages separated by 0 bytes. The Python API library (provided by i4M on request) decodes the data stream in real time. The complete protocol documentation is provided to customers on request; i4M discloses the protocol to its customers.

MQTT Streaming (via nemi EdgeBase)

MQTT configuration (mqtt_config.yml on the EdgeBase):

mqtt_streaming:
    mqtt_broker_client_id:              # leave blank for auto-generated ID
    mqtt_broker_user:                   # optional
    mqtt_broker_password:               # optional
    mqtt_broker_address: 192.168.x.x    # IP or hostname of MQTT broker
    mqtt_broker_port: 1883              # use 8883 for MQTTS
    mqtt_root_topic: edgeBase00028      # matches the EdgeBase serial ID
    mqtt_send_interval: 0.1             # seconds; 0.1 = 10 Hz publish rate

For TLS-encrypted MQTT (MQTTS), add mqtt_use_mqtts: 1 and place the certificate files (ca.crt, client.crt, client.key) in the mqtts_certs folder on the EdgeBase via FTP. Use the broker hostname (not IP) to avoid TLS certificate validation failures.

MQTT topic structure: <mqtt_root_topic>/<sensor>/<stream> — mqtt_root_topic is set in mqtt_config.yml, the sensor identifier (e.g. nemi_DAQ_1) per sensor in sensor_config.yml on the EdgeBase. Each message carries all channels of one stream of one sensor in a single JSON payload, aggregated over the send interval.

MQTT streams of nemi DAQ / DAQ nano:

Stream Content Channels
STREAM_0 Telemetry / analog channels TIMECOUNTER, CH_1 … CH_4, VOLT, RSSI
STREAM_1 IMU TIMECOUNTER, ACC_X/Y/Z, GYR_X/Y/Z, MAG_X/Y/Z, TEMP, VOLT, RSSI
STREAM_2 Digital inputs TIMECOUNTER, DIN_1 … DIN_6

The nemi DAQ uses up to three analog channels (CH_1 … CH_3), the nemi DAQ nano up to two. Treat the channel set as variable and iterate the keys present in the payload.

MQTT payload format (one timestamp per message, statistics per channel over the send interval):

{
  "timestamp": "2026-06-24T19:43:52.077665+00:00",
  "values": {
    "CH_1": {"min_value": -0.97, "max_value": 0.12, "mean_value": -0.42},
    "CH_2": {"min_value": 0.03, "max_value": 0.05, "mean_value": 0.04}
  }
}

The EdgeBase publishes with QoS 2; TLS (MQTTS) is optional. See nemi EdgeBase for the complete MQTT documentation.

MQTT is not buffered for retry

If the broker connection is unavailable at the publish moment, that value is lost. Keep logging_mode = 4 (MQTT + raw file logging) on the EdgeBase so that the .bin.bz2 files on the SSD are always the authoritative record.

Minimum sensor sampling rates for reliable 10 Hz MQTT output:

Channel configuration Min. required sensor ODR
nemi DAQ, 1 active analog channel ≥ 800 Hz
nemi DAQ, 2 active analog channels ≥ 385 Hz
nemi DAQ IMU only ≥ 208 Hz

For 1 Hz MQTT publish intervals, much lower sensor rates (≥ 52 Hz) are sufficient.

Raw Binary Data (.bin.bz2, via nemi EdgeBase)

Files stored on the EdgeBase SSD contain the same COBS-encoded binary messages as the live USB stream, compressed with bzip2. Recommended file duration is 5–10 minutes per file. i4M provides Python decoders for the efficient binary files of nemi EdgeBase (.bin.bz2) and nemi Log (.bin). They decode the files into pandas DataFrames with timestamps and values in physical units, which can then be saved as CSV, Parquet etc. or processed directly in a Python environment.

The analog front end, the IMU and the digital inputs of the nemi DAQ are transmitted in separate data messages, so each runs at its native sampling rate. Each data message carries the synchronized timestamp (1 µs resolution) of the last sample it contains; the timestamps of the earlier samples follow from the sampling rate. Timing messages relate this radio-network time to the receiver and host clock. The 32-bit time counter overflows after 2³² µs ≈ 71.6 minutes; the i4M decoders handle the overflow automatically. The complete protocol documentation is provided to customers on request; i4M discloses the protocol to its customers.

Physical-unit conversion for analog channels:

mV/V = (bitcode − 2²³) / 2²³ × 1000 / Gain

For 0–10 V channels, additionally multiply by 2.5 × 8.647058824 / 1000 to obtain volts.

Third-Party System Integration

Gantner Instruments Q.Station: Connect via nemi Connect (USB) and the GI nemione plugin. Apply the correct 0–10 V factor (8.647058824) in the plugin configuration.

PLC / fieldbus (Siemens etc.): There is no out-of-the-box PLC output. Options: (1) use the nemi Connect Python API to build a Modbus TCP, OPC-UA or similar connector; (2) use a Gantner Q.Station as intermediary with fieldbus output; (3) consume the EdgeBase MQTT values in a customer gateway.

RS232 / RS485 sensors: Digital input pins can be configured as RS485 interfaces via custom firmware (engineering project, contact i4M).

4–20 mA sensors: Connect via an external shunt resistor to convert the current loop to a voltage within the analog input range.


Troubleshooting

Radio and Connectivity

Symptom Likely cause Resolution
Node does not appear in nemi Studio / receiver Channel, radio mode or node count mismatch between node and receiver Reconfigure the node via nemi Sensor Config; match channel, radio mode and node count on both sides
Node completely absent, no data at all Lost power supply or depleted battery Check supply voltage, battery, cable continuity and pins 15 / 16 for permanent supply
Green LED on temporarily or continuously in wireless mode Internal ring buffer approx. 80 % full — radio cannot transmit fast enough Reduce sampling rate or active channels, improve the radio link, or use a faster radio mode if the range permits
Two nodes interfere / one node missing Duplicate node number on the same channel Assign unique node numbers
Node Status yellow or red, missing samples Weak link or sampling rate too high for the radio mode Move receiver closer, improve antenna placement, reduce sampling rate or node count; verify with the nemi Link 2400 Radio Channel Calculator
Node reconnects very slowly after a long disconnection Firmware bug in certain versions blocks the re-login Update firmware (contact i4M); workaround: power-cycle the node
Reception works on the bench but fails at the installed location Metal shielding or obstructions Reposition the receiver antenna; use a slower radio mode (500 kbit/s)

Data Quality

Symptom Likely cause Resolution
Spikes in strain gauge / bridge data Ultra Low Power ODR modes use pulsed bridge excitation; cable capacitance prevents settling Switch to a High Res mode (ODR 1–10); keep cables below ~5 m; a 3-sample median filter on the EdgeBase MQTT stream is available from i4M
Floating / arbitrary values on a channel Unconnected input Connect a sensor or short the input; disable unused channels
Missing samples / data gaps in recorded files Radio dropouts, receiver restart, or 32-bit counter wrap-around (~71 min) not handled Check RSSI; decode with the current i4M decoder (gap detection and timestamp correction)
Wrong 0–10 V scaling Prototype factor 10.09090909 used Use 8.647058824 for all series units from 2023 onward
Implausible / out-of-order timestamps after decoding Outdated or custom decoder Use the current i4M Python decoder; for a common time grid of several sensors apply the i4M resampling script

Power and Hardware

Symptom Likely cause Resolution
USB connected but no COM port appears Charge-only USB cable Use a data-capable USB-C cable
Node repeatedly restarts Supply voltage outside range, or defective IMU Check DC IN (5–30 V) / USB (5 V); a defective IMU causes restarts every few seconds — i4M can flash firmware that disables the IMU check as a temporary workaround
Node stopped transmitting for days External power supply failed Inspect supply, cable and connection; transmission resumes automatically after power is restored
Noise on analog channels with USB power Ungrounded USB power supply Additionally ground the nemi DAQ (GND pin)
Analog channel permanently shows no data after overvoltage / ESD event Analog front end damaged (radio, IMU and battery monitoring typically continue to work) Replace the unit and return it to i4M for failure analysis
Elevated internal temperature + rapid battery drain Water ingress or short / leakage current in a connected sensor cable Inspect housing and sensor cables; replace the unit if damage is confirmed
Virtual COM port locked after hot-unplugging USB Port not closed before unplugging Click Disconnect in nemi Sensor Config before removing the cable; otherwise close the software, re-plug the cable and reopen

Software / Receiver

Symptom Likely cause Resolution
Plugin crashes or node disappears cyclically Radio-layer errors or timestamp counter resets Check the log file; update nemi Sensor Config, nemi Studio and the nemione plugin; verify unique node numbers and matching radio settings
EdgeBase dashboard shows frozen last value EdgeBase logging process stopped receiving data Restart the logging process; i4M can deploy a watchdog script that restarts logging if no new data is stored for 5 minutes
MQTT dashboard has gaps but raw files are complete MQTT is a live monitoring stream Keep raw file logging enabled (logging_mode = 4); verify broker and cellular reliability
Trigger does not fire on the EdgeBase Wrong trigger stream / channel, stream disabled, threshold outside the signal range Check the trigger source, enable the relevant analog or IMU stream and test with a known event
Plugin or third-party software shows wrong unit scaling Input type (K option) or project-specific conversion unknown to the software Configure input type, 0–10 V factor, offset, gain and engineering-unit conversion in the plugin or in arithmetic channels

Product Changes

Hardware Variants

Variant Description Order code
nemi DAQ Kxx Input configuration K01–K05, K08–K11 (see Step 1) nemi DAQ Kxx
Low-power option 3.3–5 V input connected directly to the circuit instead of 5–30 V DC wide-range input (e.g. for lithium primary cells; no voltage converter) factory option
Weather-resistant box Housing for outdoor installation on request

Hardware Revisions

  • 1 V bridge supply removed (from production year 2024): Earlier datasheets listed "2.5 V or 1 V" for the Wheatstone bridge supply. All current deliveries use 2.5 V as the only bridge supply voltage. The supply mode of older units with the 1 V option is reported in the data messages and is evaluated by the i4M decoders.
  • 0–10 V attenuator factor revised: Early pre-series prototype units used an attenuator factor of 10.09090909. All series units (2023 onward) use 8.647058824. Any integration written against prototype units must be updated.
  • Wide-range voltage input: Earlier documentation specified 8.5–28 V DC; the current datasheet specifies 5–30 V DC.

Firmware and Software Notes

Firmware version USB configuration tool
< 10.0 wiredSensorConfig (legacy)
≥ 10.0 nemi Sensor Config v2.1+ — wiredSensorConfig is incompatible
  • XR / Extended Range radio modes require firmware updates on all participating nodes, the receiver and the EdgeBase simultaneously. Mixed old/new firmware across the network causes silent connection failures.
  • nemi Sensor Config vs. wiredSensorConfig: Do not use both tools on the same firmware ≥ 10.0 node; mixing them can corrupt the configuration.
  • Decoders: Use the current i4M Python decoders (pandas DataFrames); older decoder tools are no longer maintained.
  • Channel metadata: The analog data message does not carry all project-level metadata, e.g. whether a physical channel is wired as 0–10 V input. This context must come from the receiver software settings, the startup info messages or the installation documentation.

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio 1.1 Beta 2 (as of November 2026)
nemi Studio Web App 2026.11.04.3 (as of November 2026)
wirelessSensorPlot 7.4 (legacy, no longer maintained)
nemi Link 2400 Radio Channel Calculator Online tool, always current (replaces the Excel configuration tool)

FAQ

Applications

Can nemi DAQ measure Pt100 / Pt1000 temperature sensors? Yes, in a reference-current configuration (K05 or K11). The module supplies a 500 µA constant current through the sensor (3-wire connection with compensation current). nemi Studio converts the signal directly to °C (display unit Pt100 / Pt1000). Reference-voltage inputs (strain gauges) and reference-current inputs (Pt100) cannot be mixed on the same unit.

Can I measure both strain and temperature simultaneously? Only with two separate nemi DAQ units — one in a reference-voltage configuration (K01–K04, K08–K10) and one in a reference-current configuration (K05, K11). A single unit cannot source constant voltage (for bridges) and constant current (for RTDs) at the same time. The internal temperature sensor of the nemi DAQ measures the module temperature only.

Can geophones be connected to nemi DAQ? Yes. Geophones output a voltage proportional to vibration velocity and connect directly to the high-impedance analog inputs. Add a shunt resistor in parallel with the input if a specific loading impedance is required to control the geophone's damping. Confirm signal amplitude and select the appropriate gain before deployment.

Is nemi DAQ suitable for structural health monitoring (SHM)? Yes. Typical SHM configurations use 50–100 Hz analog sampling and a 52 Hz IMU rate. For long-term outdoor operation, use the wide-range voltage input with an external battery or a solar supply.

Can I measure displacement by double-integrating the accelerometer output? Not reliably. DC offset errors accumulate quadratically during double integration. Use a dedicated displacement sensor (potentiometer, LVDT, laser triangulation) connected to the nemi DAQ.

Can nemi DAQ measure orientation / inclination? Yes. At ±2 g ACC range with 16-bit IMU resolution, a dynamic inclination accuracy of approximately 0.1° is achievable. nemi Studio additionally provides live attitude (roll, pitch, yaw) and rotation-angle calculation from the IMU data.

Connectable Sensors

What types of digital sensors are supported? Switching sensors such as displacement, distance, level or rotation-angle sensors as well as TTL and NPN sensors. The high level is selectable in software, the low level must be below 2 V. The digital inputs are sampled at a fixed 2,000 Hz — for speed or pulse sensors, check that the maximum pulse frequency stays well below 1,000 Hz.

Can I connect a 4–20 mA current-loop sensor? Yes, by adding a shunt resistor that converts the loop current into a voltage within the analog input range. A 124 Ω shunt converts 4–20 mA to 0.496–2.48 V, which fits within the gain-1 range of a reference-voltage input.

Can I connect a 0–10 V sensor and supply it from the nemi DAQ? Yes, with a 0–10 V configuration (K02, K03, K04, K09 or K10). The DC IN voltage is routed to the sensor supply pins, so the sensor can be supplied from the nemi DAQ if the DAQ's external supply meets the sensor's requirements. In sleep mode the sensor supply is switched off.

Power Supply

What is the battery runtime? More than 14 days at a 100 Hz analog sampling rate; up to several weeks depending on configuration (lower sampling rate, intermittent operation, sleep mode). At high sampling rates, runtime is significantly shorter.

Can I charge the battery and power the device simultaneously? Yes. When connected to the wide-range input (5–30 V DC) or USB-C (5 V), the module operates from the external supply while recharging the internal battery. The battery can thus buffer an intermittent external supply.

How can I extend the battery runtime? Disable unused channels, reduce the ODR, use Ultra Low Power modes where the cable length allows it, reduce the IMU rate or disable the IMU, use intermittent or sleep mode, and use the fastest radio mode that is stable at the installation.

Can I use solar power for long-term outdoor deployment? Yes. Connect the output of a solar charge controller / buffer battery to the wide-range voltage input (5–30 V DC). Size panel and buffer battery for the sampling profile and the site's winter conditions.

Radio and Range

What radio range can I expect? Up to 350 m. Typical ranges are 20–50 m at 2 Mbit/s and 140–350 m at 125 kbit/s, depending on environment, obstacles and antenna orientation. See nemi Link 2400.

How many sensor nodes can I run on one receiver? Up to 8 nodes per radio channel. The aggregate data rate is shared among the nodes. For more nodes, or to separate high-rate and low-rate sensors, use several receivers on separate channels.

Can a Wi-Fi repeater extend the range? No. nemi Link 2400 is a proprietary 2.4 GHz radio protocol, not Wi-Fi.

How are several nemi DAQ nodes synchronized? Within one nemi Link 2400 network, all nodes are synchronized to the receiver with ±10 µs with a stable radio connection. For several receivers, configure the receiver-side synchronization (NTP, GNSS or host PC clock).

What can I do if the radio range is insufficient? Use a slower radio mode (500 kbit/s or 125 kbit/s) and verify that the sampling rate still fits, deploy several receivers each covering its own zone, or use nemi EdgeBase / nemi Log with cellular backhaul close to the sensors.

Integration

Can I use my own software to read data from nemi Connect? Yes. The USB output is a virtual COM port with a documented binary protocol (COBS-encoded messages). i4M provides a Python API on request; the complete protocol documentation is provided to customers on request; i4M discloses the protocol to its customers.

Can nemi DAQ data be sent to a Siemens PLC? Not directly. Use the Python API to write an OPC-UA or Modbus TCP connector, use a Gantner Q.Station with fieldbus output, or contact i4M for a custom integration project.

Can nemi DAQ data be streamed to Grafana? Yes, typically via EdgeBase MQTT / MQTTS into an MQTT broker and a database, with Grafana as dashboard.

Which MQTT broker should I use? Mosquitto (open source) is recommended. It supports TLS and standard MQTT 3.1.1. The EdgeBase has no broker-specific requirements beyond standard MQTT compatibility.

Can I stream reduced values to a dashboard while keeping raw data? Yes. Configure the EdgeBase with logging_mode = 4 (MQTT + raw file logging). MQTT provides aggregated values at the configured publish interval; the .bin.bz2 files contain the complete raw data.

Does the nemi DAQ have GNSS? No. GNSS is a function of the nemi EdgeBase and nemi Log receivers, where it is used for time alignment between multiple receivers.

Configuration and Software

Which tool configures the radio settings? nemi Sensor Config (v2.1 or later) via USB-C. Radio mode, channel, node number and maximum node count are configured here.

Which tool is used for live display and CSV recording? nemi Studio (Windows) or the nemi Studio Web App (browser) with a nemi Connect or a nemi EdgeBase in logging_mode 6.

Can the hardware configuration (K option) be changed later? Only by i4M technologies. Specify the required K option with your order.