Skip to content

nemi G+ ultra

nemi G+ ultra

Description

nemi G+ ultra is a compact wireless vibration sensor for high-bandwidth acceleration and vibration measurements. Its main sensor is a high-speed triaxial capacitive MEMS accelerometer with live sampling rates up to 26.7 kHz and a signal bandwidth from 0 Hz (static) up to 6.7 kHz (−3 dB). In addition, nemi G+ ultra integrates a 9-DoF IMU (3-axis accelerometer, gyroscope and magnetometer), an internal temperature sensor, an internal rechargeable lithium-ion battery and the proprietary nemi Link 2400 radio interface — all in a housing of 31.6 × 31.6 × 22.3 mm.

Compared with the standard nemi G+, nemi G+ ultra offers higher sampling rates and higher signal bandwidths. Steep anti-aliasing filters implemented on the onboard MCU allow high bandwidths even at lower sampling rates, e.g. 1.17 kHz (−3 dB) at 3.333 kHz sampling rate. This allows the bandwidth requirements of ISO/DIN ISO 20816 and DIN ISO 2954 to be met, making nemi G+ ultra suitable for condition monitoring, predictive maintenance and measurements on bearings, gearboxes, pumps and many other machines. Each of the three main accelerometer axes can be switched on or off individually, which is important for managing radio throughput at the highest sampling rates.

nemi G+ ultra requires a compatible nemi Link 2400 receiver to transmit data: nemi Connect (USB receiver for PC or Gantner Q.Station), nemi Log (compact SD logger with cellular option) or nemi EdgeBase (autonomous field gateway with 4G, edge computing and local SSD storage). The receiver handles data access, storage, downstream integration and time synchronization to host or external time sources. With nemi G+ ultra, radio ranges of up to approx. 125 m are achieved in the 1 Mbit/s mode.

Data can be transmitted as live raw samples or as pre-evaluated "smart data" computed by the onboard 64 MHz 32-bit MCU. Edge computing can be realized upon request in bilateral development projects. With its integrated battery, nemi G+ ultra operates completely wirelessly for many hours; for permanent installations, the wide-range voltage input enables continuous operation without battery management. A weather-resistant IP67 version is available on request.


Typical Applications

  • Condition monitoring and predictive maintenance — bearings, gearboxes, pumps, motors and other rotating machinery where frequency content above 1 kHz must be captured wirelessly.
  • Standard-compliant vibration measurements — the bandwidth requirements of ISO/DIN ISO 20816 and DIN ISO 2954 are met even at the lowest sampling rate (3.333 kHz, 1.17 kHz bandwidth).
  • Test benches and shaker tests — broadband vibration measurements with signal content up to 6.7 kHz and live visualization.
  • Rotating and moving components — the sensor is fully self-contained and requires no slip rings or cables.
  • Permanent installations on industrial machinery using the wide-range voltage input.

When to choose nemi G+ ultra instead of nemi G+

  • The required signal bandwidth is above 800 Hz (maximum −3 dB bandwidth of the nemi G+ at 4,000 Hz).
  • A vibration standard requires at least ~1 kHz bandwidth.
  • Individual activation of the main accelerometer axes is needed.

Technical Specifications

General

Parameter Value Unit
Dimensions 31.6 × 31.6 × 22.3 mm
Weight approx. 30 (aluminum base plate) / approx. 50 (stainless steel base plate, standard) g
Housing protection class IP41 standard; IP67 weather-resistant on request —
Operating temperature −20 to 60 °C
Onboard MCU (usable for edge computing) 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, hardware crypto features —
Mounting interface M4 thread in the base —

Dimensions of nemi G+ ultra

(All dimensions in mm)

Power Supply

Parameter Value Unit
Internal battery 1-cell lithium-ion, rechargeable —
Runtime at 3,333 Hz (all three axes active) > 10 (continuous) h
Runtime at 26.7 kHz (one axis active) > 6 (continuous) h
Charging time (0–100 %) approx. 3 h
USB power (charging and configuration) 5 (micro-USB) V
Wide-range voltage input 5 – 30 DC V
Low-power option: direct supply input (factory option) 3.3 – 5 DC V

Main MEMS Accelerometer

Parameter Value Unit
Sensor type High-resolution, high-speed, triaxial capacitive MEMS accelerometer —
Selectable sampling rates 26.666 / 13.333 / 6.666 / 3.333 kHz
Realizable −3 dB bandwidths 6.72 / 4.66 / 2.35 / 1.17 kHz
Selectable measuring ranges ± 16 / 8 / 4 / 2 g
Sensor resonance frequency 6.9 kHz
Signal resolution 16 bit
Static 3D inaccuracy without calibration (related to measuring range) < 2 %
Static 3D inaccuracy with calibration (on request) < 0.5 %
Noise density (typical) approx. 75–190 µg/√Hz
Axis activation X, Y, Z individually switchable —

Frequency Responses

Sampling rate Frequency response
26.666 kHz Frequency response at 26.666 kHz sampling rate
13.333 kHz Frequency response at 13.333 kHz sampling rate
6.666 kHz Frequency response at 6.666 kHz sampling rate
3.333 kHz Frequency response at 3.333 kHz sampling rate

Secondary 9-DoF IMU (ACC / GYR / MAG)

Parameter Value Unit
Sensor type 9-DoF MEMS IMU: 3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer —
Sampling rate 104 Hz
Signal resolution 16 bit
IMU accelerometer ranges ± 16 / 8 / 4 / 2 g
IMU gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
IMU magnetometer ranges ± 16 / 12 / 8 / 4 Gauss

Internal Temperature Sensor

Parameter Value Unit
Sampling rate 1 Hz
Measuring range −20 to 60 °C
Resolution 0.1 °C
Parameter Value
Frequency band 2.4 GHz
Topology Star (one receiver per channel)
Radio range with nemi G+ ultra up to approx. 125 m (1 Mbit/s mode)
Compatible receivers nemi Connect, nemi Log, nemi EdgeBase

Radio modes and range with nemi G+ ultra: Due to its high sampling rates, nemi G+ ultra can use the slow long-range modes only to a limited extent. The 125 kbit/s mode is practically not usable.

Radio mode Typical range (in buildings / urban environment) Usability with nemi G+ ultra
2 Mbit/s ~20 m / ~50 m All sampling rates (observe the node and axis limits per sampling rate)
1 Mbit/s ~50 m / ~125 m Reduced sampling rates / node count: one sensor at 13.333 kHz (one axis) or 6.666 kHz (all axes); three sensors at 6.666 kHz (one axis) or 3.333 kHz (two axes). 26.666 kHz only marginal. Verify with the nemi Link 2400 Radio Channel Calculator
500 kbit/s ~90 m / ~225 m Only one sensor per channel (1-node mode) at 6.666 kHz (one axis) or 3.333 kHz (all axes); three sensors only at 3.333 kHz with one axis; verify on site
125 kbit/s ~140 m / ~350 m Practically not usable (even 3.333 kHz with one axis in 1-node mode is marginal)

Range values are taken from nemi Link 2400 and depend strongly on antenna orientation, metal structures and 2.4 GHz interference; always validate the range on site.


First Commissioning

Required Hardware and Software

Item Purpose
nemi G+ ultra sensor Sensor node
nemi Connect / nemi EdgeBase / nemi Log Receiver (firmware must support the nemi G+ ultra data format, see Product Changes)
Micro-USB cable (data-capable, not charge-only) USB configuration and charging
nemi Sensor Config v2.1 or later Radio and node configuration via USB
nemi Studio v1.1 or later, or nemi Studio Web App Live display, FFT, sensor configuration and CSV recording

nemi Sensor Config and nemi Studio are provided to customers via download links (the software is not publicly available). The nemi Studio Web App runs in Chrome or Edge at https://nemi.one/studio/.

Step 1 — Power / Charge the Sensor

Connect the sensor via micro-USB to a PC or USB charger before first use. The solid red LED indicates charging is in progress; the red LED turning off indicates a full battery. A full charge from 0 % takes approximately 3 hours but is not needed for first tests. If the sensor will run from external power, connect the wide-range input only to a DC supply within the specified voltage range (5 – 30 V DC).

Step 2 — Configure the Sensor via USB

Radio parameters (channel, radio mode, node number, maximum nodes) are persistent settings written with nemi Sensor Config over USB. The procedure is identical to the nemi G+:

  1. Leave the power switch of the nemi G+ ultra in the OFF position.
  2. Connect the micro-USB cable to the PC. Use a data-capable cable; the cable delivered with the sensor is data-capable.
  3. Launch nemi Sensor Config.
  4. Switch the sensor ON. The LED briefly cycles white → green → red → blue (restart), then shows solid green + flashing yellow (USB detected; waiting for COM port).
  5. nemi Sensor Config shows the new sensor node and selects its COM port automatically. Click Connect COM-Port within approximately 10 seconds after powering the sensor; otherwise the sensor enters radio transmission mode. The LED changes to solid green + flashing blue (COM port open; awaiting settings).
  6. Enter the radio parameters from the table below and click Set nemi Link Parameters.
  7. The sensor prints its new radio parameters to the console and the COM port is closed automatically. After 10 s the sensor starts radio transmission with the new parameters.

Recommended first-test radio settings:

Parameter Recommended value Notes
nemi Link 2400 Mode 2 Mbit/s Required for the highest sampling rates
nemi Link 2400 Node Count 1 (low latency) for 26.666 kHz; 3 for multi-sensor setups See Sampling Rate, Axes and Node Count below
nemi Link 2400 Channel 0 (other preferred channels are 25, 50, 75) Default; avoids busy Wi-Fi subbands
nemi Link 2400 Node Number 1 Unique per sensor on the same channel

Important: For 26.666 kHz, the sensor and receiver must be set to 1-node (low latency) mode, and only one axis may be active. Demo units are typically pre-configured in this mode.

For more information regarding the radio network see nemi Link 2400.

Step 3 — Set Up the Receiver and Verify Data

With nemi Connect (or nemi Log in USB receiver mode):

  1. Launch nemi Studio (or open the nemi Studio Web App in Chrome/Edge).
  2. Plug the nemi Connect into a USB port. The software detects it and selects its COM port automatically.
  3. Click Connect COM-Port, wait for "Waiting for Config Messages to start …", set radio data rate, number of nodes and channel matching the sensor, and select nemi G+ ultra as module type.
  4. Select the sampling rate (ODR), measuring range and the active axes, then click Start Receiver.
  5. Power on the nemi G+ ultra without connected USB cable. Within a few seconds live data appears. Check signal strength, latency and the live sampling rate in the status displays.
  6. Use the FFT view (Live Analysis) to verify the spectrum and start a short CSV recording before mounting the sensor at its final location. In nemi Studio, Sound Output makes one axis audible, e.g. to listen to bearing or gear noise.

With nemi Log or nemi EdgeBase: Both are standalone receivers configured via configuration files. The nemi G+ ultra pairs automatically when channel and radio mode match. Use EdgeBase logging_mode 6 to connect nemi Studio to the EdgeBase over the network for a live check.

Before finalizing the installation, use the nemi Link 2400 Radio Channel Calculator (online tool) to verify that the planned combination of sensors, sampling rates, active axes and radio mode fits within the channel bandwidth.

First Data Transmission — Checklist

  1. Receiver is connected, powered and on the same channel, radio mode and node count as the sensor.
  2. Each sensor has a unique node number on the shared channel.
  3. At 26.666 kHz: only one axis active, 1-node mode, no other sensor on the channel.
  4. At rest, the axis aligned with gravity reads approximately 1 g; the other axes read near 0 g.
  5. Test at the intended installation location — do not hold the sensor in your hand during range tests; the human body strongly absorbs 2.4 GHz radio transmissions.

LED Status Codes

LED pattern Meaning
Rapid flash: white → green → red → blue Sensor restart
Solid red Battery charging via USB or wide-range voltage input
Red no longer continuously lit Battery fully charged
Solid green + flashing yellow USB data connection detected; waiting for COM port to open
Solid green + flashing blue COM port open; waiting for RF parameters or settings
Regular short red flashes (~2 s) Actively sampling and transmitting measurement data
Short green flashes every 10 s (~1 s) Sleep mode
Regular short blue flashes (~1 s) Time synchronization with the wireless network
Green LED on temporarily or continuously (in wireless mode) Internal ring buffer 80 % full — data cannot be transmitted fast enough; risk of data loss

Mounting & Connections

Mechanical Mounting

nemi G+ ultra has an M4 thread in the base. It can be screwed on, glued on or fastened magnetically. The best vibration transmission is realized with a grub screw connection.

Method Suitability Notes
M4 grub screw Best vibration transmission Preferred for high-frequency measurements and frequency analysis
Adhesive Practical for smooth, accessible surfaces Use a thin, stiff bond layer; thick or soft adhesive attenuates high frequencies
Glued mounting plate Removable or curved-surface installations Ensure the plate is rigid and tightly coupled
Magnet Fast temporary mounting on ferromagnetic surfaces Affects the integrated magnetometer; recommended: pot magnets with threaded stud (e.g. supermagnete)

Mounting material (e.g. adhesive, mounting plates, magnets) is not included; it is only supplied as an option if ordered.

Vibration transmission: At the high frequencies covered by nemi G+ ultra, the stiffness of the mounting dominates the measured frequency response. A soft adhesive layer, loose screw or flexible bracket can introduce resonances and attenuate signal content well below the sensor bandwidth.

Axis orientation: The sensor axes X, Y and Z are printed on the housing. Document and photograph the mounting orientation during installation.

Power Connections

nemi G+ ultra can be powered in three ways:

  1. Internal rechargeable battery — for temporary installations and battery-powered measurements.
  2. 5 V micro-USB — for charging and USB configuration.
  3. Wide-range voltage input (5 – 30 V DC) — for permanent installations, via the two screw terminals + and − / GND on the side of the housing. External power also charges the internal battery.

Observe supply polarity.

External Sensors

nemi G+ ultra has no external sensor interface. For connecting external analog sensors, strain gauges or other transducers, use the nemi DAQ product family.

Antenna

The internal antenna emits most strongly through the plastic cover side of the housing. Orient the sensor so the plastic cover faces the receiver whenever possible. For installations inside metal enclosures, use the nemi G+ ultra nano in a custom enclosure.


Detailed Configuration

Configuration is split into two layers:

  • Persistent radio settings — written with nemi Sensor Config over USB (channel, radio mode, node number, max. nodes).
  • Runtime measurement settings — set wirelessly via nemi Studio, the nemi Studio Web App, nemi EdgeBase YAML files or nemi Log configuration CSVs (sampling rate, range, active axes, IMU ranges, sensor mode).

Configuration Tools Reference

Tool Connection Configures
nemi Sensor Config v2.1+ USB (micro-USB) Radio channel, radio mode, node number, max. nodes per channel
nemi Studio via nemi Connect, nemi Log (USB receiver mode) or nemi EdgeBase Sampling rate, measuring range, active axes, IMU ranges, sleep / continuous / intermittent mode
nemi Studio Web App via nemi Connect (Web Serial) or nemi EdgeBase Sampling rate, measuring range, active axes, IMU ranges, sensor mode
nemi Link 2400 Radio Channel Calculator Online tool (replaces the former Excel configuration tool) Validates that sampling rates fit within the channel bandwidth
nemi EdgeBase YAML config files VPN / FTP Sensor settings, logging mode, MQTT settings
nemi Log CSV config files SD card / FTP Sensor settings, logging intervals, sleep/wake schedules

Sampling Rate and Signal Bandwidth

Sampling rate −3 dB bandwidth Typical use
26.666 kHz 6.72 kHz Maximum single-axis bandwidth; shaker tests, high-frequency fault detection
13.333 kHz 4.66 kHz High-rate three-axis measurement with one sensor
6.666 kHz 2.35 kHz Multi-sensor or three-axis condition monitoring
3.333 kHz 1.17 kHz Standard vibration monitoring per ISO/DIN ISO 20816; lowest radio load and longest runtime

Sampling Rate, Axes and Node Count

The sum sampling rate of one nemi Link 2400 channel is shared by all active nodes and axes. Disabling unused axes directly reduces radio load and extends battery life.

Sampling rate Active axes per sensor Max. sensors on one channel Node count setting
26.666 kHz 1 1 1 (low latency)
13.333 kHz 2 1 1 (low latency)
13.333 kHz 1 3 3
6.666 kHz 3 1 1 (low latency)
6.666 kHz 2 3 3
3.333 kHz 3 3 3
3.333 kHz 1 8 8

Values for 2 Mbit/s with a radio channel load below 70 % (rated good by the nemi Link 2400 Radio Channel Calculator). 13.333 kHz with all three axes reaches approx. 100 % even in 1-node mode and is therefore not recommended; 6.666 kHz with three axes on three sensors is marginal (approx. 84 %).

If a configuration approaches the channel limit: reduce the sampling rate, disable unused axes, use 1-node mode, or move additional sensors to a second receiver on a different radio channel. Verify with the nemi Link 2400 Radio Channel Calculator.

Measuring Range

Always select the smallest range that avoids clipping.

Range Resolution Typical application
± 2 g 61 µg/LSB Low-amplitude vibration
± 4 g 122 µg/LSB General machinery vibration
± 8 g 244 µg/LSB Moderate shocks and vibration
± 16 g 488 µg/LSB High-amplitude vibration and shock events

For precise absolute measurements, request factory calibration at order time. Calibration reduces the static inaccuracy from < 2 % to < 0.5 % of the measuring range.

IMU and Temperature

The IMU accelerometer, gyroscope and magnetometer ranges are configured independently of the main MEMS; setting a range to off disables the respective IMU channel. The IMU samples at 104 Hz. Use the IMU for orientation, rotation angle and attitude (nemi Studio Live Analysis → Attitude / Rotation Angle); use the main MEMS for all vibration measurements.

The internal temperature channel (1 Hz, 0.1 °C resolution) indicates device temperature and is not a substitute for a calibrated external process sensor.

Sensor Mode

Mode Behavior
0 — Sleep Sensor sleeps and wakes up periodically to receive new settings
1 — Continuous Continuous sampling and transmission
2 — Intermittent Measures for Sample [s], then sleeps for Sleep [s]; reduces average power consumption

Calendar-based schedules (e.g. active only during working hours) are not a built-in sensor feature but can be implemented via scripting on the nemi EdgeBase.

nemi EdgeBase Sensor Configuration (YAML)

On the nemi EdgeBase, nemi G+ ultra is configured in the sensor configuration file with sensor_type: ultra_vibration:

file_identifier: "nemi_G_ultra_3"   # label in file names and MQTT topics
sensor_type: ultra_vibration
sensor_mode: 1        # 0 = sleep, 1 = continuous, 2 = intermittent
vib_odr: 2            # main MEMS sampling rate code (see table)
vib_range: 1          # main MEMS range code (see table)
x_active: 1           # 1 = axis active, 0 = axis off
y_active: 1
z_active: 1
imu_acc_range: 1      # IMU ranges (IMU rate fixed at 104 Hz)
imu_gyr_range: 1
imu_mag_range: 1
sleep_time: 0         # s, intermittent mode only
sample_time: 300      # s, intermittent mode only
Code vib_odr (sampling rate) vib_range (measuring range)
0 26.666 kHz ± 2 g
1 13.333 kHz ± 4 g
2 6.666 kHz ± 8 g
3 3.333 kHz ± 16 g

Observe the axis and node limits per sampling rate (see Sampling Rate, Axes and Node Count); e.g. with vib_odr: 0 only one axis may be active. The IMU range codes are listed on the nemi EdgeBase page.

Vibration Velocity from Acceleration

To derive vibration velocity (e.g. for ISO 20816 evaluations), apply a high-pass filter (cutoff ≈ 0.5 Hz) to the acceleration signal before numerical integration. This removes DC offset and low-frequency bias that would otherwise accumulate during integration.

Time Synchronization

Within one nemi Link 2400 wireless network, the sensor clock is synchronized to the receiver with an accuracy of ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long. The receiver handles its own downstream synchronization to the host system (nemi Connect: host computer clock; nemi Log: RTC or GNSS; nemi EdgeBase: NTP or GNSS). See the respective receiver page for details.


Integration

nemi G+ ultra communicates only via nemi Link 2400 radio to a receiver. All external integration happens at the receiver level.

Receiver Best for Data access
nemi Connect PC-based live testing with nemi Studio / nemi Studio Web App, CSV recording, custom USB integration with the nemi Connect Python API, Gantner Q.Station USB virtual COM port
nemi Log Compact standalone logging; alternatively USB receiver for nemi Studio, like nemi Connect .bin files with Python decoder
nemi EdgeBase Long-term standalone field monitoring, MQTT, FTP, LTE/VPN, edge computing .bin.bz2 files via FTP, MQTT(S) streams, live TCP stream (logging_mode 6)

Integration Architecture

nemi G+ ultra sensor(s)
    │  nemi Link 2400 (2.4 GHz wireless)
    ▼
Receiver module
    ├── nemi Connect → USB → PC (nemi Studio / nemi Studio Web App / Python API / Gantner Q.Station)
    ├── nemi Log → SD card / cellular option
    └── nemi EdgeBase → Ethernet / LTE / OpenVPN
              ├── MQTT broker  (aggregated values) → Database → Dashboard
              ├── FTP server   (raw compressed binary files) → Python decoder → Pandas DataFrames
              └── TCP port 9413 (logging_mode 6) → nemi Studio live view

USB Data Messages and Decoding

nemi G+ ultra uses a more compact data message for the high-speed accelerometer stream than the standard nemi G+. The basic principles:

  • Do not reuse a nemi G+ parser for the ultra — the message structures are different.
  • Messages are framed with COBS encoding (a zero byte separates the messages).
  • Each message contains only the active axes (always in X, Y, Z order, disabled axes skipped) and reports the sampling rate, measuring range and active axes, so each message can be decoded on its own. It carries the synchronized timestamp of the last contained sample (1 µs resolution).
  • Each main MEMS sample is a 16-bit integer. Convert using the factor of the configured measuring range:
Measuring range Conversion factor
± 2 g 16,393.44 LSB/g
± 4 g 8,196.72 LSB/g
± 8 g 4,098.36 LSB/g
± 16 g 2,049.18 LSB/g
  • IMU data (104 Hz) is transmitted in a separate message.

The complete USB data message protocol documentation (message structure, conversion factors) is provided to customers on request — i4M discloses the protocol to its customers. The nemi Connect Python API package is also available on request.

nemi EdgeBase (MQTT and FTP)

For full-rate raw data, use binary (logging_mode 0) or compressed binary (logging_mode 1) logging on the nemi EdgeBase and retrieve the files via FTP. The i4M Python decoders decode the .bin.bz2 files into pandas DataFrames, which can be saved as CSV, Parquet etc. or processed directly in Python. MQTT transmits time-aggregated values (min / max / mean) and is not suitable for full-rate waveforms.

nemi G+ ultra sends via MQTT like a nemi G+: the same streams and channels and the same trigger indices apply. In the topic <root_topic>/<sensor>/<stream>, <sensor> is the file_identifier of the sensor, which also identifies it in the logged file names. See nemi EdgeBase for configuration details.

Third-Party DAQ Integration

Gantner Instruments Q.Station: Connect via nemi Connect (USB) using the GI nemione plugin. nemi G+ ultra is supported as a separate device type; each active axis appears as a separate channel.


Troubleshooting

Radio and Throughput

Symptom Likely cause Resolution
Dropped samples at 26.666 kHz Channel saturated — too many axes or additional nodes active Use 1-node mode, enable only one axis, make sure no other sensor is on the channel
No data in nemi Studio; sensor LED repeats the multicolor restart pattern Channel, radio mode or node number mismatch between sensor and receiver Reconfigure the sensor via nemi Sensor Config; match channel and radio mode on both sides
Multi-sensor setup loses data Sum sampling rate exceeds the channel budget Reduce sampling rate, disable unused axes, or split sensors across additional receivers
Green LED on continuously in wireless mode Ring buffer 80 % full — radio link cannot keep up Improve antenna placement, reduce sampling rate or active axes
Node Status yellow or red in nemi Studio Reception too weak or sampling rate too high for the radio mode Shorten the distance or reduce the sampling rate
Sensor visible but data stream unstable 2.4 GHz interference, distance or obstruction Move closer, improve the line of sight or select another radio channel

Firmware and Software Compatibility

Symptom Likely cause Resolution
Data empty, garbled or absent Receiver firmware does not support the nemi G+ ultra data format Update the nemi Connect firmware; contact i4M support
No data after opening a COM port in a custom integration Receiver waits for configuration messages Send the receiver RF configuration first, then the sensor configuration message(s)

Power and Measurement

Symptom Likely cause Resolution
USB connected but no COM port appears Charge-only USB cable Use a data-capable micro-USB cable
Sensor does not start wirelessly Battery discharged Charge via micro-USB (approx. 3 h for a full charge) and retest
Battery runtime shorter than expected High sampling rate, all axes active, continuous mode Reduce sampling rate, disable unused axes, use intermittent mode or the wide-range input
Acceleration values scaled incorrectly Wrong conversion factor in custom decoder Use the conversion factor of the configured measuring range
High-frequency vibration attenuated Soft or thick mounting layer Use the M4 thread or a stiff mounting plate
Magnetometer values offset or saturated Magnetic mounting Use a non-magnetic mounting method when magnetometer data is required
Integrated velocity drifts strongly DC offset is being integrated High-pass filter (≈ 0.5 Hz) before integration

Product Changes

Differences from nemi G+

Parameter nemi G+ nemi G+ ultra
Max. sampling rate 4,000 Hz 26,666 Hz
−3 dB bandwidth at max. rate 800 Hz 6.72 kHz
Measuring ranges ± 2 / 4 / 8 g (M08), ± 10 / 20 / 40 g (M40), ± 2 … 256 g (M256) ± 2 / 4 / 8 / 16 g
Signal resolution 20 bit (M08, M40) 16 bit
IMU sampling rate 1/25 of the main sampling rate 104 Hz
Per-axis activation No Yes
Radio range up to 350 m (125 kbit/s mode at low sampling rates) up to approx. 125 m (1 Mbit/s mode)
Data message format nemi G+ data message Compact 16-bit data message with individually switchable axes

Mechanics, mounting, power options, MCU and LED codes are identical. For bandwidths below 800 Hz, the standard nemi G+ is preferred (better noise and resolution).

Hardware Variants

Variant Description
nemi G+ ultra Housed sensor, IP41 standard; IP67 on request
nemi G+ ultra nano OEM board with identical measurement electronics, firmware and data format for integration into custom enclosures

Firmware Notes

nemi Connect firmware: A nemi Connect that was previously used only with nemi G+ sensors must be updated to support the nemi G+ ultra data format. Units shipped together with a nemi G+ ultra are pre-flashed.

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio 1.1 (as of November 2026)
nemi Studio Web App 2026.11.04.3 (as of November 2026)
wirelessSensorPlot (legacy, no longer maintained) 7.4 b3 or later required for nemi G+ ultra

FAQ

Applications

What is nemi G+ ultra mainly used for? High-bandwidth wireless vibration measurements for condition monitoring and machinery diagnostics — bearings, gearboxes, pumps and motors — where signal content above 800 Hz must be captured reliably.

When should I choose nemi G+ ultra instead of nemi G+? When you need signal bandwidth above 800 Hz, compliance with vibration standards such as ISO/DIN ISO 20816 or DIN ISO 2954, or individual axis activation. For tilt measurements, low-frequency low-noise measurements or ranges above ±16 g, choose the nemi G+.

Can I use nemi G+ ultra for vibration velocity measurements? Yes. Record acceleration, apply a high-pass filter (≈ 0.5 Hz) and integrate numerically.

Can it be used outdoors? The standard housing is rated IP41. An IP67 weather-resistant version is available on request.

Power Supply

How long does the battery last? More than 10 hours at 3.333 kHz with all three axes active, and more than 6 hours at 26.7 kHz with one axis active. Runtime extends considerably with lower sampling rates or intermittent operation.

Can the sensor run permanently? Yes. Use the wide-range voltage input (5 – 30 V DC) for continuous operation. As a low-power factory option, a 3.3 – 5 V input connected directly to the circuit is available, e.g. for a lithium primary cell (maximum efficiency, no voltage converter).

Sampling, Axes and Range

Can I use all three axes at 26.666 kHz? No. At 26.666 kHz, only one axis can be active and only one sensor can use the radio channel (1-node mode).

How many sensors can I run on one receiver? At 2 Mbit/s: one sensor per channel at 26.666 kHz (one axis), 13.333 kHz (two axes) or 6.666 kHz (all axes); three sensors at 13.333 kHz (one axis), 6.666 kHz (two axes) or 3.333 kHz (all axes); up to eight sensors at 3.333 kHz with one axis. Use additional receivers on other channels for more sensors, and check other combinations with the nemi Link 2400 Radio Channel Calculator.

Which measuring range should I use? The smallest range that does not clip the expected acceleration amplitude.

Mounting

What mounting method gives the best vibration transmission? An M4 grub screw connection.

Can I mount the sensor magnetically? Yes, but the magnet affects the integrated magnetometer. For acceleration-only measurements, magnetic mounting is practical.

Radio and Range

What wireless range can I expect? Up to approx. 125 m (urban / line of sight) in the 1 Mbit/s mode, which is the longest-range mode for regular use with nemi G+ ultra. The 500 kbit/s mode may be possible in single-sensor mode; the 125 kbit/s mode is not usable because the sampling rate cannot be reduced sufficiently. The actual range depends on antenna orientation, metal structures and 2.4 GHz interference and must be validated on site.

How accurate is timing between sensor nodes? Within one nemi Link 2400 network, sensor clocks are synchronized to the receiver with ±10 µs accuracy with a stable radio connection.

Integration and Software

Which software do I use for live display and recording? nemi Studio (Windows) or the nemi Studio Web App (browser) with a nemi Connect, a nemi Log in USB receiver mode or a nemi EdgeBase. wirelessSensorPlot is no longer maintained.

Can I use an older nemi Connect that I already use with nemi G+? Only after a firmware update that supports the nemi G+ ultra data format. Contact i4M support.

Can the nemi EdgeBase send full-rate raw vibration data via MQTT? No. MQTT sends time-aggregated values. Full-resolution raw data is retrieved via FTP.

Can I reuse my nemi G+ parser? No. nemi G+ ultra uses a different data message than the nemi G+. The Python API supports both device types.

Does the ultra nano require different software? No. The nemi G+ ultra nano behaves identically from a software and configuration perspective.