nemi Studio Web App¶

Description¶
The nemi Studio Web App shows the measurement data of the nemione® wireless sensors and wireless sensor nodes in the nemi Link 2400 network live, configures the radio network and the sensors, and records the data as a CSV file. The receiver is a nemi Connect (USB) or a nemi EdgeBase (network). A nemi Log in USB receiver mode can be used like a nemi Connect. Up to eight sensors can be displayed at the same time.
The app does not need to be installed — it runs in a web browser on a PC, Mac or tablet. Together with the Windows desktop software nemi Studio, it replaces the legacy software wirelessSensorPlot.
The App Runs in Your Browser, Not on Our Server¶
- The server only delivers the files of the app (HTML, CSS, JavaScript). After that, all code runs in your browser on your device.
- Your browser connects to the receiver directly: to the nemi Connect through the Web Serial API (USB), to the nemi EdgeBase through a WebSocket in your network.
- i4M does not receive any data. Measurement data, recordings and settings never leave your device. The app contains no analytics or tracking services.
- Settings (language, connection, sensor configuration, views, calibrations) are stored locally by the browser on your device and restored at the next start. Recordings are saved as a file on your device.
Typical Applications¶
- Quick commissioning and live checks without installing software — on any PC with Chrome or Edge and a nemi Connect.
- Live access to a nemi EdgeBase installation from a laptop, Mac or iPad via VPN, Ethernet or a direct connection — the app is served by the EdgeBase itself.
- Tilt measurement with nemi G+ — high-resolution display in degrees and mm/m with zeroing and 180° reversal calibration.
- Vibration analysis — FFT and waterfall spectrograms (2D/3D) to observe run-ups, resonances and impacts.
- Orientation display — artificial horizon (roll/pitch) and 3D orientation with compass.
- Synchronised recordings of all sensors into one CSV file on a common time grid.
Technical Specifications¶
Where to Find the App¶
| Receiver | How to open |
|---|---|
| nemi Connect (USB) | Open https://nemi.one/studio/ in Chrome or Edge. |
| nemi EdgeBase (network) | The app runs on the EdgeBase itself: enter http://<address of the EdgeBase>:8080/ in the address bar of the browser. |
nemi EdgeBase produced before November 2026
The Web App is included in the EdgeBase software from November 2026. Devices produced before November 2026 require a software update, which i4M can install remotely on request.
The app detects by itself where it was loaded from and only offers the matching connection type. The other one is greyed out.
Browser Support¶
Recommended: Google Chrome, Microsoft Edge or another Chromium-based browser in a current version. Only there are all functions available without restrictions.
| Browser | nemi Connect (USB) | nemi EdgeBase (network) | Time of day in the recording | Recording |
|---|---|---|---|---|
| Chrome, Edge, Chromium-based | Yes | Yes | Precise (browser clock 0.1 ms, jitter typically 0.3 ms) | Directly into the chosen file, no size limit |
| Firefox | Only in newer versions with Web Serial | Yes | Coarser (browser clock only 1 ms, jitter about 1 ms) | As a download when stopping, about 100 MB at most |
| Safari (Mac, iPad, iPhone) | No (no Web Serial) | Yes | Coarser (browser clock only 1 ms) | As a download when stopping, about 100 MB at most |
- Without Web Serial (Safari, older Firefox versions) no nemi Connect can be connected. The status line then says so. The app on a nemi EdgeBase works in every current browser.
- For recordings with time columns and for long recordings, use Chrome or Edge.
- Use a current version of Safari (16.4 or later). Older versions do not align the columns and are more likely to keep old files in their cache after an update.
Supported Sensor Types¶
| Type | Settings in the app |
|---|---|
| nemi G+ | Range ±2 / 4 / 8 g or ±10 / 20 / 40 g depending on the device variant, sample rate 125 Hz to 4 kHz, IMU ranges (ACC, GYR, MAG). IMU rate fixed at 1/25 of the sample rate (2,000 Hz → 80 Hz). |
| nemi G+ ultra | Range ±2 to ±16 g, sample rate 3.333 to 26.667 kHz, axes X / Y / Z individually switchable, IMU ranges. IMU rate fixed at 104 Hz. |
| nemi G+ (new) | Range as for the nemi G+, sample rate 31.25 Hz to 4 kHz, axes X / Y / Z individually switchable, IMU ranges. IMU rate fixed at 104 Hz. |
| nemi DAQ | Gain 1×, 4×, 8×, 16×, 32×, 64× or 128× for each measuring channel 1 to 3 (off switches the channel off); sample rate of the measuring channels (depends on the number of active channels, (LP) marks low-power levels); IMU rate 52 to 3,332 Hz; IMU ranges. |
| off | This sensor ID is not used. A sensor with this SID keeps measuring unchanged. |
| sleep | Puts the sensor to sleep: it stops sending and saves power. To wake it up, choose the type again and press Send settings. It can take about 30 s until it reports back. |
nemi G+ (new)
The type nemi G+ (new) is prepared for a future firmware upgrade of the nemi G+ (new data messages, individually switchable axes to reduce the data volume). Current nemi G+ sensors are configured as nemi G+.
The nano variants (nemi G+ nano, nemi G+ ultra nano, nemi DAQ nano) are configured with the type of the respective standard device.
nemi Studio Web App vs. nemi Studio¶
| Feature | nemi Studio Web App | nemi Studio |
|---|---|---|
| Platform | Browser (Chrome / Edge recommended; Firefox, Safari with restrictions) | Windows 10+ desktop application |
| Installation | None — open https://nemi.one/studio/ or the address of the EdgeBase |
Unzip ZIP package, run nemiStudio.exe |
| nemi Connect (USB) | Yes, in browsers with Web Serial (Chrome, Edge, newer Firefox) | Yes (virtual COM port) |
| nemi EdgeBase (network) | Yes — the app is served by the EdgeBase itself; works in every current browser incl. iPad | Yes (logging_mode 6, port 9413) |
| Live display | Up to 8 sensor columns side by side, magnified view | 3 node columns (any of 8 nodes selectable), Big Plot, Common Plot |
| Analysis | FFT, Waterfall 2D/3D, Tilt Measurement, Orientation 2D/3D | FFT, Attitude (3D), Rotation Angle, Sound Output |
| nemi G+ M256 extended ranges | Not listed in the current manual | Yes (16 … 256 g) |
| Zero / scaling | Zero for nemi DAQ channels and tilt angle | Node Zero and Scaling (offset and scale for every channel) |
| Recording | One common CSV file on a common time grid | One CSV per node and data stream; optional resampled common file |
| Settings storage | Locally in the browser | INI files, last_session_settings.ini |
Migration from wirelessSensorPlot¶
wirelessSensorPlot is no longer maintained. Former users should note:
- No installation and no INI files: the configuration is stored in the browser and restored automatically at the next start.
- Settings are sent with Send settings (highlighted in yellow when changes are pending) instead of Update Node Settings.
- All active sensors are recorded into one CSV file on a common time grid (instead of separate files per node).
- Persistent radio parameters of the sensor nodes are still written with nemi Sensor Config via USB.
- For the Windows workflow closest to wirelessSensorPlot (separate files per node, INI settings files), use nemi Studio.
First Commissioning¶
Prerequisites¶
- The sensor nodes have been configured once with nemi Sensor Config via USB (radio channel, radio data rate, node number, number of nodes per channel). See the respective sensor page, e.g. nemi G+.
- A nemi Connect and Chrome or Edge, or a nemi EdgeBase reachable via VPN, Ethernet or a direct connection.
Connecting a nemi Connect (USB)¶
- Plug the nemi Connect into the computer via USB.
- Open
https://nemi.one/studio/in Chrome or Edge. In the App settings, Connection is fixed to nemi Connect (USB) there. - Configure the radio network and the sensors (see Detailed Configuration). This can also be done later.
- Press Connect and select the port of the nemi Connect in the browser dialog.
- The status line shows the steps: open the connection, restart the nemi Connect, reopen, send the settings to the radio module and the sensors. This takes about 10 s.
- After that, it reads "waiting for sensor data". The sensors typically need 10 to 20 s until they have joined. As soon as data arrive, the line turns green and a column appears for each sensor.

- nemi Connect reset on connect (default: on) restarts the nemi Connect when connecting, so that it is in a defined state. If reopening after the restart fails, clear the checkbox and connect again.
- Disconnect ends a running recording, resets the nemi Connect and releases the port.
Connecting a nemi EdgeBase (Network)¶
The EdgeBase contains its own radio receiver and serves the app itself. In forwarding mode it passes the data stream of its receiver to the app over the network and accepts the settings from the app. The app then behaves as if connected to a nemi Connect.
- Set
logging_mode 6on the EdgeBase: open the filesensor_config.ymlvia the nemibase_config login, set the entrylogging_mode: 6in the sectionnemi_link_2400_baseand save. After about one minute the EdgeBase has applied the new setting; a restart is not required. Only in this mode does it accept connections from the app. - Bring the computer or tablet into the same network as the EdgeBase, for example via the i4M VPN, via Ethernet or via a direct connection.
- Enter the address of the EdgeBase in the address bar of the browser:
http://<address of the EdgeBase>:8080/. The app is loaded from the EdgeBase. - Press Connect. In the App settings, Connection is already fixed to nemi EdgeBase (network), and the address of the EdgeBase is filled in under EdgeBase IP (Port 9413). No browser dialog appears.

- Auto reconnect (default: on): if the connection drops, the app reconnects by itself, first after 2 s, then at growing intervals up to every 15 s. If nothing at all arrives for 15 s, it rebuilds the connection. If no sensor data arrive for 30 s, it sends the settings again.
- Only one app can be connected to the EdgeBase at a time. A new connection takes over the existing one.
- With
?autoconnect=1appended to the address (for example in a bookmark), the app connects as soon as it is opened. - Over Wi-Fi or VPN, the transit time of the data varies more than over USB. The time of day in the recording is correspondingly less precise. The synchronisation of the sensors among each other is not affected.
First Measurement — Checklist¶
- RF channel, RF bit rate and Max. sensors/channel match the settings of the sensor nodes.
- Each sensor has a unique sensor ID (SID) on the channel, and the sensor type in its box matches the actual device.
- All columns show the configured sample rate (S/s) without yellow or red indication.
- The Time sync line in the App settings shows active (about 10 to 20 s after connecting) before starting a recording with time columns.
User Interface¶

From top to bottom the page consists of these areas:
| Area | Content |
|---|---|
| 1 Header | Title with version number. Clicking a logo opens the respective homepage in a new window. |
| 2 Toolbar | Connect, Disconnect, Send settings, Record data, Reset plots (clears all curves), Time window (2 to 60 s), Display (Dark / Light), language (DE / EN) and Help. The language can be switched while the app is running. |
| 3 Status line | What the app is doing right now: steps while connecting, waiting for sensor data, errors. Yellow = working, green = connected, red = error. |
| 4 App settings | Connection type, address of the EdgeBase, checkboxes for the behaviour of the app and the state of the time synchronisation. Collapsible. |
| 5 Node / radio settings | Radio configuration (channel, bit rate, number of sensors) and one box per sensor with type, measuring range, sample rate etc. Collapsible. |
| 6 Sensor columns | One column N 1, N 2 … per received sensor (N = node, the number is the sensor ID). From the top: header with sensor type and state values, upper plot (main sensor), lower plot (IMU) and the sensor log. |
| 7 Log | Messages of the app and the receiver with the time of day. |
Structure of a sensor column:
- Both plots have the same head: the first row holds the View selection, the second the settings of the selected view.
- The magnifier (for the upper plot at the right of the column header, for the lower plot at the right of its head) shows exactly this display full screen. Go back with ✕, another click on the magnifier or the Esc key.
- Equal elements are at the same height in all columns. With more than three sensors (more on wide screens), further rows of columns follow.
Integrated help: Help at the right of the toolbar opens a help window with the same explanations as this manual, in the language selected in the app.
Detailed Configuration¶
Everything for this is in the Node / radio settings area. The app sends the settings to the receiver and the sensors when connecting.

Radio Configuration¶
| Setting | Meaning |
|---|---|
| RF channel | Radio channel 0 to 79 (default 0). Receiver and sensors operate on this channel. Several radio networks within range need different channels. |
| RF bit rate | 2 Mbit/s, 1 Mbit/s, 500 kbit/s or 125 kbit/s. High bit rates carry more data and are required for high sample rates. Low bit rates increase the range but carry considerably less. Check the radio channel load with the nemi Link 2400 Radio Channel Calculator. |
| Max. sensors/channel | 1, 3 or 8: how many sensors share the radio channel. The app shows that many sensor boxes. |
These values must match the persistent radio parameters of the sensor nodes (written with nemi Sensor Config). For range figures and bandwidth planning, see nemi Link 2400.
Sensors¶
Every sensor has a sensor ID (SID 1 to 8) and its own box. Choose the type first; the matching settings then appear (see Supported Sensor Types).
Note
The app detects the type of a sensor itself when receiving (green badge in the column header). The settings in the sensor box determine what is sent to the sensor and how its raw values are converted. They should therefore match the sensor that is actually present.
Changing Settings¶
- All settings can be changed at any time, also while connected.
- As soon as a change has not been sent yet, Send settings is highlighted in yellow. A click sends the new settings and rebuilds the plots.
- If RF channel, RF bit rate or Max. sensors/channel were changed, the app restarts the receiver in the process; otherwise the radio module does not adopt the values. This takes about 10 s over USB and about 3 s over the network.
- Without a connection, changed settings apply from the next connect.
Checkboxes¶
| Checkbox | Where | Effect |
|---|---|---|
| Auto reconnect | App settings, network only | Reconnect automatically after the connection was lost. |
| nemi Connect reset on connect | App settings, USB only | Restart the nemi Connect when connecting (recommended). |
| Show logs | App settings | Shows or hides the sensor logs and the log at the bottom. Messages are still collected. |
| 3D interpolation | App settings | Smooth motion in Orientation 2D, Orientation 3D and Tilt Measurement: intermediate frames are computed; in return the display runs about 0.1 to 0.25 s behind the measurement. |
| Lock 3D views | App settings | Locks rotating and zooming of the 3D displays, so that you can scroll over them on a tablet. In the magnified view they can always be moved. |
| Record Unix time | App settings | Additional column UNIX_TIMESTAMP in the recording. |
| Record date/time | App settings | Additional column DATE_TIME (local time) in the recording. |
| Axes X / Y / Z | Sensor box (G+ ultra, nemi G+ (new)) | Which axes the sensor measures and sends. |
| Record tilt angle | Sensor box (nemi G+, nemi G+ (new)) | Writes the displayed tilt angle to the recording. |
| Record Euler angles | Sensor box (all types) | Writes roll, pitch and yaw to the recording. |
The four recording checkboxes each apply from the next start of a recording.
Live Data & Analysis¶
Upper Plot: Main Sensor¶
The upper plot shows the main sensor: acceleration or vibration in g (nemi G+, G+ ultra, nemi G+ (new)) or the measuring channels in mV/V (nemi DAQ). View selects the display, separately for each sensor.
Time Signal¶
| nemi G+: time signal | nemi DAQ: time signal after Zero |
|---|---|
![]() |
![]() |
- The measured values over time, one curve per axis or channel. The time axis is the time of the sensors in seconds. It is synchronised in the radio network and the same for all sensors, so simultaneous events appear at the same position in all columns.
- Time window in the toolbar sets how many seconds are visible. The pointer over the plot shows the values at that position in the legend.
- nemi DAQ — Zero sets all active measuring channels to 0: the app averages each channel over 1 s and subtracts this value, e.g. to set the zero point of a measuring bridge in the unloaded state. Another click undoes the zeroing. The zeroing applies to the display, the analyses and the recording and stays stored until the channel settings (active channels, gain) are changed. The subtracted values are shown in the log.
FFT (Frequency Spectrum)¶

- About five times per second the app takes the latest N samples (N is a power of two, at most roughly 2 s of signal), subtracts the mean, applies a Hann window and computes the FFT. Shown is the amplitude spectrum in the unit of the signal: a sine with an amplitude of 1 g gives a peak of 1 g.
- f min / f max: displayed frequency range. Empty means 0 Hz up to half the sample rate.
- Scale: Linear or dB.
- The narrower the frequency range, the finer the resolution. The title shows it as Δf.
Waterfall 2D and Waterfall 3D (Spectrogram)¶
| Waterfall 2D | Waterfall 3D |
|---|---|
![]() |
![]() |
- The same spectra as for FFT, for one channel stacked continuously. This shows how frequencies change over time (run-up, resonance, impacts). The amplitude is shown in dB as a colour.
- Waterfall 2D: frequency to the right, time downwards, the newest row at the top.
- Waterfall 3D: the same data as a surface; the front is new, height and colour show the amplitude. Drag to rotate, mouse wheel or two fingers to zoom, double-click to restore the initial view.
- f min / f max: frequency range. Channel: which axis or measuring channel. The colour scale adapts itself to the visible values; the length of the history follows the time window.
Tilt Measurement (nemi G+ and nemi G+ (new) only)¶

- The acceleration sensor also measures gravity. The tilt angle follows from the ratio of the two axes perpendicular to the rotation axis. A low-pass filter at 1 Hz removes vibration and noise beforehand. The angle refers to the nearest 90° position, so the sensor can be mounted in any orientation.
- Shown are the angle in degrees with three decimals, the slope in mm/m, a scale with a pointer and the history. The history axis zooms in automatically so that even the smallest changes are visible.
- Axis: the sensor axis about which the sensor tilts. Range ±: display range of the scale (0.1 to 45°); the measurement itself is not affected.
- Zero: sets the current tilt as 0°, e.g. the installed position on a structure. Another click undoes the zeroing.
- Calibrate (180° reversal): determines the zero-point error of the sensor. Place the sensor at rest, Measure, then rotate it 180° about the vertical axis, place it at the same spot, Measure, Apply. After that, the display shows the true tilt of the surface. The calibration is stored per SID and mounting position.
- For tilt measurement, a sample rate of 125 Hz is sufficient.
Note
If a view reads "data gap – waiting", data are currently missing in the evaluated time span (e.g. after a radio disturbance). The display continues by itself as soon as gap-free data are available again.
Lower Plot: IMU¶
Every sensor additionally contains an IMU with an accelerometer (ACC), a gyroscope (GYR) and a magnetometer (MAG). The lower plot shows either their signals or the orientation in space computed from them.
| Time signal ACC | Time signal GYR |
|---|---|
![]() |
![]() |
Time signal ACC / GYR / MAG shows the three axes of the respective sensor over time: acceleration in g, angular rate in °/s, magnetic field in gauss. The measuring ranges are set in the sensor box; the data rate of the IMU is shown next to View.
How the Orientation Is Computed¶
- A sensor fusion combines the three sensors: the angular rate provides the fast motion, the acceleration keeps roll and pitch stable in the long term, the magnetometer (compass) keeps the heading (yaw) stable.
- Without the compass, yaw drifts slowly (less than 1° per minute). Roll and pitch do not drift.
- The app learns the zero-point error of the gyroscope while the sensor is at rest. Shortly after the start, leave the sensor lying still for a few seconds.
- The computation always runs, even if another view is selected.
| Orientation 2D (artificial horizon) | Orientation 3D |
|---|---|
![]() |
![]() |
Orientation 2D shows only roll and pitch like an attitude indicator, with numerical values. Roll axis selects which sensor axis points along the system: rotation about this axis is roll, its inclination is pitch.
Orientation 3D shows a cube or the model of the sensor moving like the real sensor, with roll, pitch and yaw, the state of the compass and of the gyroscope zero point.
- Compass: uses the magnetometer for the heading. It first calibrates itself: rotate the sensor slowly about the vertical axis and also tilt it until the display reaches 100 %. If the app detects a disturbing field (steel, magnets, motors), it ignores the compass temporarily.
- 3D model: model of the sensor instead of the cube. The sensors currently do not report whether they are a nano version; the app therefore shows the model of the standard device. For nano versions, clear the checkbox to show the neutral cube.
- Zero: place the sensor with its X axis pointing away from you and press. That direction then counts as north. The tilt stays real. Another click undoes the zeroing.
- If the line |a| permanently shows a value clearly different from 1.0 g, the configured ACC range does not match the sensor.
For a smooth orientation display, the IMU should deliver at least 20 values per second. For the nemi G+ this means a sample rate of at least 500 Hz.
Column Header Values and Reception¶

| Display | Meaning |
|---|---|
| N 1 | Node with the sensor ID (SID) 1 |
| nemi G+ | Type reported by the sensor itself. As long as it reads "detecting…", no data message has arrived yet. |
| °C | Temperature inside the sensor |
| V | Supply or battery voltage of the sensor |
| dB | Signal strength of the radio reception (RSSI) as magnitude of the level: 62 dB stands for −62 dBm. The smaller the number, the stronger the signal. |
| S/s, kS/s | Received samples per second of the main sensor. In undisturbed operation the value equals the configured sample rate. |
Are Samples Being Lost?¶
The sensors send their samples in packets and buffer them when the radio link is briefly disturbed. After a disturbance they deliver the backlog. A pause therefore does not yet mean a loss. The data rate shows both separately:
| Display | Meaning |
|---|---|
| 2.0 kS/s | Normal: data arrive, nothing is missing. |
| 0 S/s (yellow) | No data of this stream for at least 1 s. The sensor is sending late or not at all. If it delivers everything afterwards, the display returns to normal without turning red. |
| 1.7 kS/s (red for 1 s) | Samples are missing. There is a gap in the sensor's timestamps because its buffer overflowed or messages were lost. The tooltip gives the estimated number. |
- Good reception: small dB value, data rate equal to the sample rate, no yellow and no red.
- With frequent yellow or red: reduce the distance to the receiver or avoid obstacles, choose another RF channel (Wi-Fi and Bluetooth use the same frequency band), reduce the sample rate or the number of axes, or choose a higher RF bit rate.
Warning
In a recording, lost samples do not stay empty but are interpolated across the gap. Watch out for red indications during an important measurement.
Recording Data¶
Procedure¶
- Press Record data.
- Chrome / Edge: choose location and file name (suggestion: date and time). The app writes continuously and directly into this file.
- Firefox / Safari: enter a file name. The app collects the data in memory and saves them as a download when stopping. At about 100 MB it ends the recording by itself and saves.
- While recording, the button is red and reads Stop recording. A click ends the recording.
All channels of all currently active sensors are recorded, regardless of the selected view and the time window. Disconnect ends a running recording and saves it.
Synchronised Time Axis and Common Time Grid¶
In the radio network, the clocks of all sensors are synchronised to the time of the receiver. Every sample receives a unique timestamp, so all samples lie on one common, time-synchronised axis. Because the sensors sample at different rates, the app projects the samples automatically onto a common grid, so that every row belongs to exactly one instant:
- Grid rate = highest sample rate of all active channels, rounded up to a full 100 Hz (below 100 Hz to a full 10 Hz). Example: nemi G+ at 2,000 Hz and nemi DAQ at 800 Hz give 2,000 rows per second. The rate is written to the log at the start.
- Every channel is interpolated linearly between its two neighbouring samples. Slower channels (e.g. the IMU) thereby get intermediate values, but no additional information.
- The basis are the timestamps of the samples, not the time of arrival. Data delivered late therefore end up at the correct position.
- A row is only written once all channels have reached that instant. During a radio pause the file therefore waits. Only if a channel stays away for more than 120 s does the file continue without it; its cells then stay empty.
Format of the CSV File¶
Separator semicolon (;), decimal separator point (.), up to six decimals. The first row contains the column names, in which S1, S2 … stand for the sensor ID. An empty cell means there is no value for this instant.
| Column | Unit | Content |
|---|---|---|
TIMECOUNTER |
s | Time of the grid, starts at 0 |
UNIX_TIMESTAMP |
s | Seconds since 1 Jan 1970 (UTC) with microseconds, e.g. 1791883767.460774. Only with Record Unix time. |
DATE_TIME |
– | Date and time in local time with microseconds, e.g. 2026-10-13 11:29:27.460774. Only with Record date/time. |
S1_VIB_X, _Y, _Z |
g | Main sensor of nemi G+, G+ ultra, nemi G+ (new): acceleration or vibration per axis |
S1_TILT_X |
° | Tilt angle as displayed in Tilt Measurement (after calibration and zeroing). The last letter is the selected rotation axis. Only with Record tilt angle. |
S2_CH_1, _2, _3 |
mV/V | Measuring channels of nemi DAQ, after Zero as displayed |
S1_ACC_X, _Y, _Z |
g | IMU: acceleration |
S1_GYR_X, _Y, _Z |
°/s | IMU: angular rate |
S1_MAG_X, _Y, _Z |
gauss | IMU: magnetic field |
S1_ROLL, S1_PITCH, S1_YAW |
° | Computed orientation as displayed in Orientation 3D, after zeroing. Roll −180 to 180°, pitch −90 to 90°, yaw 0 to 360°. Only with Record Euler angles. |
Temperature, voltage and signal strength are not recorded.
Time Synchronisation¶
- Within the radio network, the clocks of all sensors are synchronised to the time of the receiver: ±10 µs with a stable radio connection. With a poor connection, some synchronisation events have to be discarded because their transit time is too long.
- The synchronised time of the radio network counts from the start of the receiver and knows no time of day. Once per second the receiver therefore reports its own time. The app compares it with the clock of your computer and converts the time of every sample to the time of day. Varying transit times and the different rates of the two clocks are compensated continuously.
- The state is shown next to the checkboxes in the App settings: "Time sync: active · jitter … · drift …". It becomes active about 10 to 20 s after connecting. Jitter is the typical delay of the timing messages, drift the rate difference of the clocks.
- Accuracy: over USB in Chrome or Edge about 1 ms relative to the clock of your computer. In Firefox and Safari and over Wi-Fi or VPN it is lower. In absolute terms, the time is only as accurate as the computer's clock itself — synchronise it with a time server (NTP).
- As long as this alignment is not established, the time columns stay empty. The recording runs nevertheless.
Note
The checkboxes Record Unix time, Record date/time, Record tilt angle and Record Euler angles are evaluated at the start of the recording. If you change them while a recording is running, the effect only shows in the next file.
Troubleshooting¶
| Problem | Possible cause / solution |
|---|---|
| nemi Connect (USB) is greyed out or cannot be selected | The browser has no Web Serial support (Safari, older Firefox) or the app was loaded from an EdgeBase. Use Chrome or Edge and open https://nemi.one/studio/. |
| No port of the nemi Connect in the browser dialog | Re-plug the nemi Connect; use a data-capable USB cable; close other programs that use the port (e.g. nemi Studio). |
| Reopening after the reset of the nemi Connect fails | Clear nemi Connect reset on connect and connect again. |
| Status line stays at "waiting for sensor data" | Check RF channel, RF bit rate and Max. sensors/channel (must match the sensors); switch the sensors on; sensors need 10 to 20 s to join. |
| EdgeBase does not accept the connection | Check that logging_mode: 6 is set in sensor_config.yml and that the computer can reach the EdgeBase (VPN, Ethernet). Only one app can be connected at a time. |
| Frequent yellow or red data-rate indication | Reduce distance or obstacles, choose another RF channel, reduce sample rate or number of axes, or choose a higher RF bit rate. |
| View shows "data gap – waiting" | Data are missing in the evaluated time span; the display continues automatically when gap-free data are available again. |
| Time columns in the recording are empty | Time synchronisation not yet active — wait 10 to 20 s after connecting, check the Time sync line. |
| Recording stopped by itself at about 100 MB | Firefox / Safari limit. Use Chrome or Edge for long recordings. |
| |a| permanently clearly different from 1.0 g | The configured ACC range does not match the sensor. |
| Old version shown after an update | Reload the page without cache (Ctrl+F5, on a Mac Cmd+Shift+R). |
| Sensor in sleep does not wake up | Choose the type again and press Send settings; it can take about 30 s until it reports back. |
For further questions, please contact your contact person at i4M technologies.
Product Changes¶
Version Information¶
| Software | Version | Status |
|---|---|---|
| nemi Studio Web App | 2026.11.04.3 | Current (November 2026) |
| wirelessSensorPlot | 7.4 | Legacy, no longer maintained — replaced by nemi Studio / nemi Studio Web App |
The version number is shown next to the title in the header. If the browser still shows the old number after an update, reload the page once without the cache (Ctrl+F5, on a Mac Cmd+Shift+R).
FAQ¶
General¶
Does the nemi Studio Web App need to be installed?
No. It runs in a current web browser. Open https://nemi.one/studio/ for a nemi Connect, or http://<address of the EdgeBase>:8080/ for a nemi EdgeBase. On EdgeBase devices produced before November 2026, the Web App requires a software update (installed remotely by i4M on request).
Are my measurement data sent to i4M? No. The server only delivers the app files. All code runs in your browser; measurement data, recordings and settings never leave your device. The app contains no analytics or tracking.
Which browser should I use? Google Chrome or Microsoft Edge (or another Chromium-based browser) in a current version. Only there are USB connection, precise time of day and unlimited recording available.
Can I use the app on a Mac, iPad or iPhone? Yes, with a nemi EdgeBase: the app on the EdgeBase works in every current browser including Safari. A nemi Connect cannot be used with Safari because it has no Web Serial support.
Where are my settings stored? Locally in the browser on your device. They are restored automatically at the next start. There are no settings files to save or load.
How do I know which version I am using? The version number is shown next to the title. After an update, reload once without cache (Ctrl+F5 / Cmd+Shift+R) if the old number is still shown.
I used wirelessSensorPlot before — what changes? No installation, settings stored in the browser, Send settings instead of Update Node Settings, and one common CSV file for all sensors. For a Windows workflow closest to wirelessSensorPlot, use nemi Studio.
Receiver and Radio Network¶
How many sensors can be displayed? Up to eight sensors at the same time (one radio channel with Max. sensors/channel = 8). Each sensor gets its own column.
Can I mix nemi G+, nemi G+ ultra and nemi DAQ on one channel? Yes. Each sensor ID has its own sensor box with its own type. The app also detects the type itself (green badge in the column header).
Do I need to press Send settings after changing a parameter? Yes. Pending changes are indicated by a yellow Send settings button. Changes of RF channel, RF bit rate or sensors per channel restart the receiver (about 10 s over USB, about 3 s over the network).
Can two people connect to the same EdgeBase at the same time? No. Only one app can be connected to the EdgeBase at a time; a new connection takes over the existing one.
Can two receivers listen on the same radio channel at the same time? No. Two active receivers on the same channel cause collisions and data loss. Use different RF channels for different sensor groups.
Which RF bit rate should I choose? The slowest bit rate that still carries the required sample rates: lower bit rates increase the range but carry considerably less data. See nemi Link 2400.
Analysis¶
Can the app show an FFT or spectrogram? Yes. Select FFT, Waterfall 2D or Waterfall 3D as view of the upper plot.
Can I use the nemi G+ as an inclinometer with the app? Yes. Select Tilt Measurement, choose the rotation axis, use a sample rate of 125 Hz, and perform the 180° reversal calibration for the true tilt of the surface. Zero sets the installed position as reference.
Why does the 3D model not look like my sensor? The nano versions (bare OEM boards) do not report that they are nano versions, so the model of the standard device is shown. Clear the 3D model checkbox to show a neutral cube.
Why does the yaw angle drift? Without a calibrated compass, yaw drifts slowly (less than 1° per minute). Enable Compass, rotate the sensor slowly about the vertical axis and tilt it until the calibration reaches 100 %. Avoid steel, magnets and motors nearby.
Data and Files¶
What does the recorded file look like?
One CSV file with all active sensors on a common time grid: semicolon separator, decimal point, column names in the first row (S1_VIB_X, S2_CH_1 …).
Are lost samples visible in the recording? No — lost samples are interpolated across the gap. Watch for red data-rate indications during important measurements.
Are temperature, battery voltage and signal strength recorded? No. If you need them in the data, use nemi Studio, whose IMU file contains temperature, battery voltage and RSSI.
Is there a limit for the recording length? In Chrome and Edge the app writes directly into the file without size limit. In Firefox and Safari the recording is kept in memory and ends automatically at about 100 MB.
Is the app suitable for long-term unattended measurements? Only as long as the browser tab stays open and connected. For autonomous long-term monitoring use nemi EdgeBase or nemi Log.
Time Synchronisation¶
How precisely are the sensors synchronised with each other? Within the radio network, all sensor clocks are synchronised to the receiver: ±10 µs with a stable radio connection. With a poor connection, some synchronisation events are discarded because their transit time is too long.
How accurate is the time of day in the recording? About 1 ms relative to the computer clock over USB in Chrome or Edge; lower in Firefox, Safari and over Wi-Fi or VPN. Keep the computer clock synchronised via NTP.
Why are the time columns empty? The alignment with the computer clock becomes active about 10 to 20 s after connecting. Until then the time columns stay empty, but the recording runs.