Skip to content

nemi G+ nano

nemi G+ nano

Description

nemi G+ nano is a compact OEM sensor module in the form of a circuit board for precise wireless measurement of acceleration, vibration, rotation rates, rotation angles, magnetic fields and temperature along and around all three axes. It carries the same measurement electronics as the housed nemi G+: a high-resolution triaxial capacitive MEMS accelerometer (20-bit, up to 4,000 Hz), a 9-DoF IMU (3-axis accelerometer, gyroscope and magnetometer), an internal temperature sensor, a 64 MHz 32-bit MCU and the nemi Link 2400 radio interface — on a board of only 30 × 30 mm and 6.5 g.

nemi G+ nano is intended for integration into the smallest installation spaces: inside machines, rotating assemblies (e.g. pitch bearings of wind turbines or gearboxes), test rigs and customer-specific enclosures, where a complete housed sensor does not fit or adds too much mass. It turns components and machines into smart products.

This page describes hardware revision 1.2 and later. The board has no integrated battery; the integrator selects the power source:

  • a rechargeable Li-ion battery on the BAT pin (default, charged via the onboard charger and micro-USB),
  • a non-rechargeable battery or other 3.3–5 V DC source on the BAT pin (charger disabled via solder jumpers),
  • a 5–30 V DC source on the wide-range DCIN pin (e.g. 24 V DC, a 12 V lead-acid battery or 2–8 lithium primary cells in series),
  • 5 V via micro-USB.

Three mounting options are available, all based on the same aluminum baseplate, which is not included as standard and can be ordered additionally: baseplate only, baseplate with cover, and a potted waterproof housing with magnetic USB connector.

nemi G+ nano requires a compatible nemi Link 2400 receiver: nemi Connect (USB receiver for PC or Gantner Q.Station), nemi Log (compact SD logger with cellular option) or nemi EdgeBase (autonomous field gateway with 4G, edge computing and local SSD storage). Data can be transmitted as live raw samples or as pre-evaluated "smart data" computed by edge analytics.


Typical Applications

  • Condition monitoring on rotating machinery — wind turbine pitch bearings, gearboxes, shafts and production machines. The small, light board can be integrated directly into the rotating part; no slip rings or cables are required.
  • Structural health monitoring (SHM) — bridges, towers and machine frames. The 20-bit primary accelerometer measures down to DC, enabling simultaneous tilt and vibration capture.
  • Long-term autonomous monitoring — with large primary-cell packs on the DCIN pin, runtimes of many months are possible (see Power Consumption and Battery Life).
  • OEM integration — integration into a customer-specific product or enclosure with customer-specific power supply.
  • High-g measurements — with the M256 variant, accelerations up to ±256 g can be captured.
  • Rotation rate, direction detection and rotation angle estimation — using the IMU gyroscope (up to ±4,000 °/s) and the gravity vector.

Technical Specifications

General

Parameter Value Unit
Dimensions (with connectors) 30 × 30 × 12 mm
Dimensions (without connectors) 30 × 30 × 4.2 mm
Weight (with connectors) 6.5 g
Mounting hole pattern 24 × 24 mm
Housing protection class Without housing (bare board); waterproof housing available as mounting option —
Operating temperature −25 to 85 °C
Onboard MCU, usable for edge computing 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, hardware crypto features —

Board dimensions of nemi G+ nano

(All dimensions in mm)

Power Supply

Parameter Value Unit
Supply voltage on BAT pin — rechargeable battery 3.3–4.2 V
Supply voltage on BAT pin — non-rechargeable battery, power bank or other DC source 3.3–5 V
Supply voltage on DCIN pin (wide-range input) 5–30 V
USB power (charging and configuration) 5 V via micro-USB V
Charging cut-off voltage (rechargeable battery) 4.2 V
Charging current (CC-CV) 120 mA

Primary MEMS Accelerometer

Parameter Value Unit
Sensor type High-resolution triaxial capacitive MEMS accelerometer —
Selectable sampling rates 4,000 / 2,000 / 1,000 / 500 / 250 / 125 Hz
Realizable −3 dB bandwidths 800 / 500 / 250 / 125 / 62.5 / 31.25 Hz
Sampling-rate stability (full temperature range) ± 50 ppm
Non-linearity (related to measuring range) 0.1 %
Cross-axis sensitivity 1.0 %
Static 3D inaccuracy without calibration < 8 % of range
Static 3D inaccuracy with calibration (on request) < 0.1 (M08) / < 1.0 (M40) / < 1.0 (M256) % of range
M08 variant — selectable ranges ± 8 / 4 / 2 g
M08 variant — resonance frequency / resolution 2,400 / 20 Hz / bit
M40 variant — selectable ranges ± 40 / 20 / 10 g
M40 variant — resonance frequency / resolution 5,500 / 20 Hz / bit
M256 variant — selectable ranges ± 256 / 128 / 64 / 32 / 16 / 8 / 4 / 2 g
M256 variant — resonance frequency / resolution 2,400 / 16 Hz / bit

Frequency Responses

Frequency response ± 8 g variant Frequency response ± 40 g variant
Frequency response ± 8 g variant Frequency response ± 40 g variant

The noise figures are identical to the housed nemi G+.

Secondary 9-DoF IMU (ACC / GYR / MAG)

Parameter Value Unit
Sensor type 9-DoF MEMS IMU: 3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer —
Sampling rate 1/25 of primary rate (e.g. 160 Hz at 4,000 Hz primary) Hz
Signal resolution 16 bit
IMU accelerometer ranges ± 16 / 8 / 4 / 2 g
IMU gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
IMU magnetometer ranges ± 16 / 12 / 8 / 4 Gauss

Internal Temperature Sensor

Parameter Value Unit
Measuring range −20 to 60 °C
Parameter Value
Frequency band 2.4 GHz
Topology Star (one receiver per channel)
Max. sensor nodes per channel 8
Range up to 350 m (depending on radio mode and environment)
Antenna connector u.FL, for an external 2.4 GHz / 50 Ω antenna
Compatible receivers nemi Connect, nemi Log, nemi EdgeBase

First Commissioning

ESD-sensitive device

nemi G+ nano has only limited built-in ESD protection. Handle the bare board with proper ESD precautions (grounded mat, wrist strap) during all installation steps.

Required Hardware and Software

Item Purpose
nemi G+ nano (bare board, or on the optional baseplate, with cover or in waterproof housing) Sensor node
Power source (battery or DC supply, see Power Connections) Power supply
2.4 GHz / 50 Ω antenna with u.FL connector (directly or via adapter cable) — only antennas approved by i4M (not included as standard, available on request) Radio link
nemi Connect / nemi EdgeBase / nemi Log Receiver
Micro-USB cable (data-capable, not charge-only); magnetic USB cable for the waterproof housing USB configuration and charging
nemi Sensor Config v2.1 or later Radio configuration via USB
nemi Studio v1.1 or later, or nemi Studio Web App Live display, configuration of measurement settings and CSV recording (with nemi Connect)

Antenna required — use only approved antennas

Before operating the radio, an antenna must be connected to the u.FL connector of the board. No antenna is included as standard; i4M supplies approved antennas on request. Only antennas approved by i4M may be used — please ask i4M for approved antennas.

Step 1 — Check the Power Configuration

  1. Check the solder jumper configuration before connecting a battery: both jumpers closed = charger active (default, for rechargeable batteries); both jumpers open = charger disconnected (for non-rechargeable batteries). Never connect a non-rechargeable battery with closed jumpers.
  2. Connect the power source to the power terminal (see Power Connections): battery or 3.3–5 V DC to GND / BAT, or 5–30 V DC to GND / DCIN. Observe polarity.
  3. Set the slide switch: top position = powered from BAT, bottom position = powered from DCIN. In the other position the board is off (or, if both sources are connected, the switch selects between them).

A rechargeable battery connected to BAT can be charged via micro-USB (solid red LED while charging).

Step 2 — Configure the Sensor via USB

Radio parameters (channel, radio mode, node number, maximum nodes) are persistent settings written with nemi Sensor Config over USB. The procedure is the same as for the nemi G+:

  1. Switch the board off.
  2. Connect the micro-USB cable (data-capable) to the PC and launch nemi Sensor Config.
  3. Switch the board on. The LED cycles white → green → red → blue (restart), then shows solid green + flashing yellow (USB detected; waiting for COM port).
  4. Click Connect COM-Port within approx. 10 seconds. The LED changes to solid green + flashing blue.
  5. Enter the radio parameters and click Set nemi Link Parameters. The sensor prints its new parameters to the console and starts radio transmission mode after approx. 10 s.

Recommended first-test radio settings:

Parameter Recommended value Notes
nemi Link 2400 Mode 2 Mbit/s Required for 4,000 Hz with 3 nodes (with 1 node, 1 Mbit/s is also sufficient); adequate range for bench tests
nemi Link 2400 Node Count 1 or 3 Up to 8 nodes possible, but the max. sampling rate is reduced
nemi Link 2400 Channel 0 (other preferred channels: 25, 50, 75) Default; avoids busy Wi-Fi subbands
nemi Link 2400 Node Number 1 Unique per sensor on the same channel

On delivery, the factory radio settings are listed in the delivery documentation. Keep this record; it is needed when setting up the receiver.

Step 3 — Set Up the Receiver and Verify Data

With nemi Connect (or nemi Log in USB receiver mode):

  1. Launch nemi Studio (or open the nemi Studio Web App in Chrome/Edge).
  2. Plug in the nemi Connect, click Connect COM-Port, select the same radio data rate, node count and channel as the sensor.
  3. Select module type nemi G+ nano for the node (also for the M256 variant) and click Start Receiver.
  4. Switch on the nemi G+ nano. Within a few seconds live data should appear. Check signal strength, latency and the live sampling rate.
  5. Set sampling rate and measurement ranges and click Update Node Settings.
  6. Verify the radio link margin at the final installation position before closing the enclosure or leaving the site.

With nemi Log or nemi EdgeBase: configure the receiver via its configuration files; the sensor pairs automatically when channel and radio mode match. With nemi EdgeBase, use logging_mode 6 to check live data in nemi Studio over the network.

Before finalizing an installation, verify with the nemi Link 2400 Radio Channel Calculator (online tool) that the planned combination of sensors, sampling rates, channel and radio mode fits within the channel bandwidth.

LED Status Codes

LED pattern Meaning
Rapid flash: white → green → red → blue Sensor restart
Solid red Battery charging via USB or wide-range voltage input
Red no longer continuously lit Battery fully charged
Solid green + flashing yellow USB data connection detected; waiting for COM port to open
Solid green + flashing blue COM port open; waiting for RF parameters or settings
Short red flashes (~2 s) Actively sampling and transmitting measurement data
Short green flashes every 10 s Sleep mode
Short blue flashes (~1 s) Time synchronization with wireless network
Green LED on temporarily or continuously (in wireless mode) Internal ring buffer 80 % full — data cannot be transmitted fast enough; risk of data loss

Range Considerations

Radio mode Typical range (in buildings – in urban environment) Max live sampling rate (with max. 3 active sensors on the radio channel)
2 Mbit/s 20–50 m 4,000 Hz
1 Mbit/s 50–125 m 2,000 Hz
500 kbit/s 90–225 m 1,000 Hz
125 kbit/s 140–350 m 250 Hz

Range depends strongly on the antenna environment of the integrated board: metal enclosures, nearby metal parts and human body tissue strongly attenuate 2.4 GHz signals. Always validate the range with the board in its final enclosure and mounting position.


Mounting & Connections

Mechanical Mounting

All mounting options are based on the same aluminum baseplate (33 × 33 mm) to which the board is screwed (M3 screws). The baseplate is not included as standard and can be ordered additionally. The baseplate has an M4 thread in the center and can be screwed or glued to the measuring object. The best vibration transmission is achieved with a grub screw connection. Using the baseplate is recommended in all cases because the THT connector legs protrude from the underside of the board.

Mounting options of nemi G+ nano

Option Description
Baseplate Optional, can be ordered additionally. Board screwed onto the aluminum baseplate; screw (M4) or glue to the measuring object.
Baseplate with cover Compact cover (33.2 × 33.2 × 14.6 mm, 16.5 mm including terminal block) protects the electronics. Terminal block, slide switch and micro-USB connector remain accessible. Sensor axes and measuring range are marked on the cover.
Waterproof housing 3D-printed housing (33 × 33 × 19.4 mm) on the baseplate, completely enclosing and potted with resin. Charging and radio configuration via a magnetic USB connector — the housing does not need to be opened.

Baseplate dimensions

Dimensions of cover and waterproof housing

(All dimensions in mm)

Axis orientation: Document and photograph the mounting orientation during installation; on the cover and waterproof housing the X, Y and Z axes are printed.

Power Connections

Board overview: micro-USB, solder jumpers, slide switch and power terminal

The 4-pin power terminal has the following pin assignment:

Pin Signal Function
GND Ground Ground
BAT Battery Battery or DC source 3.3–5 V (3.3–4.2 V for rechargeable Li-ion)
RES Reserved Do not connect
DCIN DC input Wide-range DC input 5–30 V

Powered by BAT pin — slide switch in top position. For example a rechargeable Li-ion battery (the battery must have its own protection circuit!), a non-rechargeable lithium battery or another DC supply between 3.3 and 5 V.

Powered by BAT pin

Powered by DCIN pin — slide switch in bottom position. For example 24 V DC, 2–8 non-rechargeable lithium batteries in series or a 12 V lead-acid battery.

Powered by DCIN pin

In the other switch position the board is off; if both sources are connected, the slide switch selects between them. The 5–30 V DCIN input is available with every power option. The micro-USB connector can also be used as 5 V power supply.

Warning

Reversing the polarity of the power terminal can permanently damage the board.

Solder Jumper Configuration

The power option is set via two solder jumpers on the top side of the board. Check them before connecting a battery.

Power option Solder jumpers and function
Rechargeable battery (default) Both jumpers closed: the BAT pin is connected to the charger IC; the battery is charged via USB with the internal charging circuit (CC-CV, 4.2 V, 120 mA). The battery voltage is measured.
Non-rechargeable battery Both jumpers open: the BAT pin is NOT connected to the charger IC (prevents accidental charging of a primary cell). The battery voltage is measured. Input range 3.3–5 V.

Position of the solder jumpers

External Sensors

nemi G+ nano has no external sensor interface. For external analog sensors, strain gauges or other transducers, use nemi DAQ nano.

Antenna

nemi G+ nano has a u.FL connector for an external 2.4 GHz / 50 Ω antenna. Connect the antenna before operating the radio, either directly or via a suitable adapter cable. No antenna is included as standard; i4M supplies approved antennas on request. Only antennas approved by i4M may be used — please ask i4M for approved antennas. The radio performance depends on the surrounding enclosure and the antenna placement: keep metal parts away from the antenna.

For installations inside metal or shielded enclosures, route the antenna to the outside of the shielded volume. A typical adapter chain for an industrial enclosure is:

board u.FL → u.FL-to-RP-SMA cable → RP-SMA bulkhead / panel connector → external antenna

Use only an i4M-approved antenna and adapter cable, and secure the u.FL plug mechanically in vibrating or rotating installations.


Detailed Configuration

Configuration is split into two layers:

  • Persistent radio settings — written via nemi Sensor Config over USB (channel, radio mode, node number, max nodes).
  • Measurement settings — sent wirelessly by the receiver side: nemi Studio, nemi Studio Web App, nemi EdgeBase YAML files or nemi Log configuration CSVs (sampling rate, ranges, IMU channels, operating mode). These settings are sent to the node when the receiver starts; after a restart the node transmits with default settings (e.g. 4,000 Hz) for a few seconds until it receives the configured settings.

Configuration Tools Reference

Tool Connection Configures
nemi Sensor Config v2.1+ USB (micro-USB) Radio channel, radio mode, node number, max nodes per channel
nemi Studio / nemi Studio Web App via nemi Connect, nemi Log (USB receiver mode, nemi Studio) or nemi EdgeBase Sampling rate, measurement ranges, IMU ranges, sleep / continuous / intermittent mode
nemi Link 2400 Radio Channel Calculator Online tool (replaces the former Excel configuration tool) Validates that sampling rates fit within channel bandwidth
nemi EdgeBase YAML config files VPN / FTP Sampling rate, ranges, trigger, logging, MQTT
nemi Log CSV config files SD card / FTP Sampling rate, ranges, trigger, logging intervals, sleep/wake schedules

Sampling Rate

Sampling rate −3 dB bandwidth IMU rate (1/25)
4,000 Hz 800 Hz 160 Hz
2,000 Hz 500 Hz 80 Hz
1,000 Hz 250 Hz 40 Hz
500 Hz 125 Hz 20 Hz
250 Hz 62.5 Hz 10 Hz
125 Hz 31.25 Hz 5 Hz

Choose the lowest sampling rate that covers the highest frequency of interest with adequate margin (the −3 dB point is at 1/5 of the sampling rate). For structural frequencies up to ~80 Hz, 250–500 Hz is appropriate; for clean signal content up to ~150 Hz use 1,000 Hz. The standard minimum is 125 Hz; a project-specific firmware can reduce this to approx. 72.5 Hz — contact i4M.

Measurement Ranges

Always select the smallest range that avoids clipping.

Sensor Available ranges Notes
Primary accelerometer M08 ±2 / 4 / 8 g Lowest noise and highest resolution at ±2 g
Primary accelerometer M40 ±10 / 20 / 40 g Shocks, impacts, high centrifugal acceleration
Primary accelerometer M256 ±2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 g 16-bit; ranges from 32 g use a separate high-g element whose zero offset can be several tenths of a g — use Node Zero and Scaling in nemi Studio if required
IMU accelerometer ±2 / 4 / 8 / 16 g (or off) Independent of the primary range
IMU gyroscope ±125 / 250 / 500 / 1,000 / 2,000 / 4,000 °/s (or off) Select above the expected peak rotation rate
IMU magnetometer ±4 / 8 / 12 / 16 Gauss (or off) Disable if not needed to save power

The hardware variant (M08, M40 or M256) is fixed at order time. In nemi Studio, the extended M256 ranges (16 … 256 g) are only enabled once the node has reported the matching hardware at start-up.

Radio Mode, Channel and Node Configuration

Parameter Values Guidance
Radio mode 2 Mbit/s / 1 Mbit/s / 500 kbit/s / 125 kbit/s Use the fastest mode that provides adequate range; faster modes reduce on-air time and power consumption
Channel 0–79 All nodes of one network use the same channel; channel 0 is the default. Separate independent networks by at least 10 channels (channel 10 works, but is slightly more exposed to potential WLAN interference than channel 0)
Node number 1 … max nodes Unique per sensor on the same channel
Max nodes 1, 3 or 8 ≥ number of active sensors on the channel; at 4,000 Hz, 3 nodes is the practical maximum

Sleep Mode

The receiver can command the sensor into sleep mode. In sleep mode the current consumption drops below 100 µA (battery supply on BAT). The sensor remains asleep until woken by a receiver command — even if the receiver is switched off or out of range in the meantime. With the DCIN input at elevated voltage, the quiescent current of the DC-DC converter dominates (approx. 1 mA at 14.4 V).

Power Consumption and Battery Life

Reference consumption: at 1,000 Hz, ACC, GYR and MAG active, radio mode 2 Mbit/s, nemi G+ nano consumes an average of 4.66 mA at 3.3 V (15.4 mW) on the BAT pin.

Power source Connected to Nominal capacity [Wh] Efficiency at nominal voltage Effective capacity [Wh] Projected runtime [days]
1 × Saft LS 14250 GND and BAT 4.3 ~89 % (3.6 V) 3.8 10
1 × Saft LS 33600 GND and BAT 61.2 ~89 % (3.6 V) 54.5 147
2 × Saft LS 33600 in series GND and DCIN 122.4 ~85 % (7.2 V) 104 281
4 × Saft LS 33600 in series GND and DCIN 244.8 ~81 % (14.4 V) 198 535

The runtime is calculated with the nominal battery capacity. The usable capacity depends on temperature, discharge rate and other environmental factors. For Saft Li-SOCl₂ primary cells, the voltage can drop below 3.3 V at temperatures below 0 °C; a single-cell configuration on BAT is therefore not recommended below 0 °C. Check the solder jumper configuration before connecting a non-rechargeable battery.

Power source examples:

Type Example Nominal voltage [V] Capacity [Wh] Dimensions [mm]
Rechargeable (LiPo) Renata ICP641620PA 3.7 0.6 7 × 16 × 22
Rechargeable (Li-ion) Panasonic NCR18650B 3.7 12.6 Ø 18 × 69
Non-rechargeable (Li-SOCl₂) Saft LS14250 3.6 4.3 Ø 14 × 25
Non-rechargeable (Li-SOCl₂) Saft LS33600 3.6 61 Ø 33 × 61
Non-rechargeable (lithium primary) Varta 9 V battery 9 10.8 26 × 49 × 16
Non-rechargeable (alkaline, 3 in series) Varta Industrial Pro 4020 D Mono 4.5 76.5 3 × Ø 34.2 × 61.5

Further planning values (measured on the nemi G+ family, @ 3.3 V):

Configuration Approx. current
Sleep mode (battery on BAT) < 100 µA
1,000 Hz primary @ 1 Mbit/s radio ~5.8 mA
1,000 Hz primary @ 500 kbit/s radio ~8.5 mA
Sleep mode via DCIN at 14.4 V ~1 mA (converter quiescent current)

To maximize battery life: use the lowest acceptable sampling rate, disable unused IMU channels (GYR and MAG in particular), use the fastest radio mode the range allows and use sleep / intermittent operation for duty-cycled installations. Measure the current with the real hardware and supply voltage before finalizing battery sizing.

Time Synchronization

Within one nemi Link 2400 network, the sensor clocks are synchronized to the receiver with an accuracy of ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long. Synchronization events are visible as short blue LED flashes.

The receiver handles the downstream synchronization: nemi Connect follows the host computer clock (nemi Studio assigns synchronized timestamps; keep the PC synchronized via NTP), nemi EdgeBase uses NTP or GNSS, nemi Log uses its RTC or GNSS. For a common time axis of several nodes, use the Resample Data function of nemi Studio or the i4M resampling script for receiver files.


Integration

nemi G+ nano communicates only via nemi Link 2400 with a receiver; all external integration happens at the receiver level. It does not support Wi-Fi, Bluetooth or direct PLC/SCADA connections.

Receiver Best for Data access
nemi Connect PC-based commissioning, lab tests, live display with nemi Studio / nemi Studio Web App, CSV recording, custom USB integration with the nemi Connect Python API, Gantner Q.Station plugin USB virtual COM port
nemi Log Compact autonomous logging, cellular telemetry; alternatively USB receiver for nemi Studio, like nemi Connect nemi Log .bin files with Python decoder, MQTT / FTP with cellular option
nemi EdgeBase Long-term autonomous field monitoring, edge analytics, MQTT, FTP, LTE / VPN .bin.bz2 files (Python decoder), MQTT streams, TCP/IP live forwarding (logging_mode 6)

Data Channels

Channel group Signal names Unit
Primary MEMS VIB_X, VIB_Y, VIB_Z g
IMU accelerometer ACC_X, ACC_Y, ACC_Z g
IMU gyroscope GYR_X, GYR_Y, GYR_Z °/s
IMU magnetometer MAG_X, MAG_Y, MAG_Z Gauss
Temperature TEMP °C
Battery voltage VOLT V
Radio signal strength RSSI —

Trigger Channel Mapping (nemi EdgeBase)

For triggered recording on the nemi EdgeBase, the nemi G+ nano channels are addressed as follows:

trigger_stream trigger_channel Signal
0 0 / 1 / 2 Primary MEMS X / Y / Z
1 0 / 1 / 2 IMU ACC X / Y / Z
2 0 / 1 / 2 IMU GYR X / Y / Z
3 0 / 1 / 2 IMU MAG X / Y / Z
4 0 Temperature

Use the primary MEMS (trigger_stream: 0) as trigger source where possible: the IMU accelerometer is more temperature-sensitive and can shift the trigger baseline.

Decoders and APIs

  • nemi Connect Python API — live data as pandas DataFrames (on request from i4M).
  • Python decoders — decode the .bin.bz2 files of the nemi EdgeBase and the .bin files of the nemi Log into pandas DataFrames, which can be saved as CSV, Parquet etc. or processed directly in Python.
  • nemi Studio — CSV recording (semicolon-separated) with optional resampling to a common time grid.

Troubleshooting

Power and Startup

Symptom Likely cause Resolution
Sensor does not start Slide switch in wrong position or power source on the wrong pin Slide switch top = BAT, bottom = DCIN; check pin assignment and polarity
Sensor does not start on BAT with primary cell at low temperature Li-SOCl₂ voltage below 3.3 V below 0 °C Use a multi-cell pack on DCIN for applications below 0 °C
Non-rechargeable battery gets warm / is charged Solder jumpers closed (charger active) Disconnect immediately; open both solder jumpers before connecting primary cells
Battery runtime much shorter than expected High DC-DC quiescent current at elevated DCIN voltage, slow radio mode or weak radio link Measure current at the actual supply voltage; use the fastest reliable radio mode; disable unused IMU channels
USB connected but no COM port appears Charge-only USB cable Use a data-capable micro-USB cable

Radio and Data Loss

Symptom Likely cause Resolution
Increasing missing samples over time Weakening battery (most common), changed antenna environment, new shielding near the installation Check signal strength and battery voltage in nemi Studio; measure supply voltage under load
Green LED on continuously in wireless mode Ring buffer 80 % full — radio link cannot keep up Improve radio link, reduce sampling rate or node count, or use a faster radio mode
Sensor appears on the wrong receiver Same channel as another receiver network Read and reconfigure the sensor via USB with nemi Sensor Config; use separated channels
Only one of two sensors appears reliably Duplicate node number on the same channel Assign unique node numbers; set max nodes ≥ number of active sensors
Signal strength 0 % but some data still arrives Severely degraded radio link Treat the link as unreliable; check u.FL seating, antenna and adapter cables, enclosure, metal parts near the antenna, receiver antenna and supply voltage
Link worked before but degrades over time Weakening battery, loosened or rotated antenna, new shielding near the installation Inspect the antenna path and u.FL connection; measure supply voltage and current under load

Configuration

Symptom Likely cause Resolution
Node transmits at 4,000 Hz after restart Default settings until the receiver resends the configuration Normal; the configured settings are applied after a few seconds (up to approx. one minute)
Receiver channel changed but sensor still appears elsewhere Only the receiver was changed Reconfigure the sensor via USB with nemi Sensor Config, then power-cycle
M256 ranges (16 … 256 g) greyed out in nemi Studio Node has not yet reported its hardware Switch the node off and on again while nemi Studio is connected

Triggering (nemi EdgeBase)

Symptom Likely cause Resolution
Trigger stops firing although vibration is visible Temperature-induced baseline shift on the trigger channel Adjust threshold with margin; switch trigger source from IMU ACC to primary MEMS

Product Changes

Hardware Variants and Options

Variant Primary MEMS ranges Resolution Order code
nemi G+ nano M08 ±8 / 4 / 2 g 20 bit nemi G+ nano M08
nemi G+ nano M40 ±40 / 20 / 10 g 20 bit nemi G+ nano M40
nemi G+ nano M256 ±256 / 128 / 64 / 32 / 16 / 8 / 4 / 2 g 16 bit nemi G+ nano M256

Mounting options (to be ordered additionally): baseplate, baseplate with cover, waterproof potted housing with magnetic USB connector. Factory calibration on request.

Hardware Revision 1.2

Hardware revision 1.2 introduced the current power concept: 4-pin power terminal (GND / BAT / RES / DCIN), slide switch for source selection, solder jumpers for rechargeable / non-rechargeable batteries and the wide-range DCIN input available with every power option.

Earlier hardware revisions (before Rev. 1.2) were delivered in two power options with a 6-pin connector:

  • Option E1 — battery-powered variant with energy harvesting input. The energy harvesting (solar) option is no longer available.
  • Option E2 — 5–30 V DC input on pins 1/2 (pins 3–6 not connected), no battery charging.

Like the current revision, these boards have a u.FL connector for an external 2.4 GHz / 50 Ω antenna. Contact i4M with the hardware revision when servicing older units.

Firmware and Software

Topic Details
Minimum sampling rate Standard minimum 125 Hz; project-specific firmware down to approx. 72.5 Hz on request.

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio 1.1 (as of November 2026)
nemi Studio Web App 2026.11.04.3 (as of November 2026)
wirelessSensorPlot (legacy, no longer maintained) 7.4
nemi Link 2400 Radio Channel Calculator Online tool, always current (replaces the Excel configuration tool)

FAQ

Applications

What is the difference between nemi G+ and nemi G+ nano? nemi G+ is a complete housed sensor with integrated rechargeable battery. nemi G+ nano is the same measurement electronics as an OEM board without integrated battery, for integration into machines or custom enclosures. Both use nemi Link 2400 and work with the same receivers and software.

Is nemi G+ nano suitable for wind turbine pitch bearing or gearbox monitoring? Yes — this is one of its primary applications. The small board is integrated directly into the rotating part. For long-term operation, use large primary-cell packs on the DCIN input (e.g. 4 × Saft LS 33600 in series for approx. 535 days at 1,000 Hz).

Is nemi G+ nano suitable for a small high-speed rotating shaft? Calculate the centrifugal acceleration first (a = ω² × r). At 5,000 rpm and 12.5 mm radius, approx. 350 g occur — beyond the range of all variants, including M256.

Can nemi G+ nano measure torque? No. Torque requires strain gauges or a torque transducer and an analog data acquisition node such as nemi DAQ nano.

Can nemi G+ nano measure rotation angles? Yes, using the IMU gyroscope and the gravity vector. nemi Studio calculates attitude (roll, pitch, yaw) and the rotation angle of sensors on rotating shafts live. Accuracy depends on rotation speed, IMU sampling rate (fixed at 1/25 of the primary rate) and gyroscope range; validate on a representative test rig.

Is nemi G+ nano ATEX certified? No. The complete assembly (board, enclosure, antenna, power source) must be assessed by the system integrator.

Connectable Sensors

Does nemi G+ nano have external analog inputs? No. Use nemi DAQ nano for strain gauges, Pt100/Pt1000 or voltage sensors.

Can an M40 be converted into an M08 or M256 by software? No. M08, M40 and M256 are hardware variants; software selects only the ranges of the installed variant.

What is the difference between "Range" and "IMU ACC Range"? "Range" controls the primary high-resolution MEMS accelerometer, "IMU ACC Range" the IMU accelerometer. They are independent sensors with independent settings.

Power Supply

How can nemi G+ nano be powered? Via the BAT pin (rechargeable Li-ion 3.3–4.2 V, or non-rechargeable battery / DC source 3.3–5 V with the solder jumpers open), via the DCIN pin (5–30 V DC) or via micro-USB (5 V). The slide switch selects BAT (top) or DCIN (bottom).

Can nemi G+ nano be powered from 12 V or 24 V? Yes, via the DCIN pin (5–30 V). At higher input voltages the DC-DC converter quiescent current increases the sleep current (approx. 1 mA at 14.4 V instead of < 100 µA on BAT).

Can I use a non-rechargeable battery? Yes. Open both solder jumpers first so that the charger is disconnected from the BAT pin.

How long does a battery last? At 1,000 Hz with ACC, GYR and MAG active and 2 Mbit/s, the average consumption is 4.66 mA at 3.3 V. This gives approx. 10 days with one Saft LS 14250, approx. 147 days with one Saft LS 33600 and approx. 535 days with four LS 33600 in series on DCIN. Lower sampling rates, disabled IMU channels and sleep / intermittent operation extend the runtime.

Does lowering the sampling rate help battery life? Yes. Lower sampling rates reduce data volume and radio load. The standard minimum is 125 Hz; lower rates require a project-specific firmware.

Which radio mode gives the best battery life? The fastest mode that still provides reliable range. Faster modes reduce on-air time and current consumption.

Range and Antenna

Can nemi G+ nano be installed inside a metal enclosure? Yes, but the antenna must not remain inside the metal enclosure: 2.4 GHz signals are strongly attenuated by metal. Connect an external 2.4 GHz / 50 Ω antenna to the u.FL connector and route it to the outside (e.g. via a u.FL-to-RP-SMA cable and a panel connector). Always validate the range in the final installation.

What should I check if signal strength shows 0 % but some data still arrives? Treat the link as unreliable. Check the u.FL connection, antenna and adapter cables, the enclosure and metal parts near the antenna, receiver antenna position and the supply voltage under load.

Integration

Can nemi G+ nano connect directly to Wi-Fi, Bluetooth, a PLC or SCADA? No. It requires a nemi Link 2400 receiver. From the receiver, data is available via the Python API, CSV / binary files or MQTT.

How do I get data into Python, MATLAB or a database? Live via nemi Connect and the Python API; as CSV with nemi Studio or the nemi Studio Web App; as binary files from nemi EdgeBase / nemi Log decoded with the Python decoder; as MQTT streams from nemi EdgeBase into InfluxDB or any MQTT-compatible platform.

Can one receiver receive several nemi G+ nano sensors? Yes — up to 8 per radio channel, within the capacity of the selected sampling rate and radio mode. All sensors of one network use the same channel and need unique node numbers.

Are multiple sensors synchronized? Yes. All nodes on one nemi Link 2400 channel are synchronized to the receiver with ±10 µs accuracy with a stable radio connection. For a common time axis, use the resampling function of nemi Studio or the i4M resampling script.