nemi Link 2400¶
Description¶
The nemi Link 2400 is the wireless sensor network layer of the nemione measurement platform, developed by i4M technologies. It operates in the 2.4 GHz ISM band and is a battery-oriented, low-power radio technology with a star topology: one receiver module collects synchronized data from up to 8 wireless sensor nodes on one radio channel.
The system's distinguishing capabilities are
- Live measurement data transmission at high sampling rates and high resolutions: Measurement data is transmitted live with high temporal and vertical resolution and low latency.
- Precise time synchronization: each sensor node maintains a 1 µs-resolution clock that is continuously synchronized to the receiver's master clock via the radio protocol. All transmitted data packets carry this Timecounter value at the moment of measurement, enabling coherent timestamps across all nodes without any external time reference at the node level.
- Robust, buffered data transmission for no missing samples: The receiver acknowledges every data packet that is transmitted. If data packets cannot be transmitted, they are temporarily stored in the node's buffer / cache and transmitted as soon as the connection is restored. Interruptions lasting from several seconds to several minutes can be bridged, ensuring that no samples are lost.
- Adaptability for various applications: The nemi Link 2400 operates at four selectable radio speeds, offering a range-versus-bandwidth trade-off from 20 m indoors at 2 Mbit/s to 350 m line-of-sight at 125 kbit/s. Higher speeds provide more sampling bandwidth and better energy efficiency per delivered sample over short distances. Lower speeds provide longer range and higher link budget at the cost of lower aggregate sampling rate and shorter battery runtime for continuous transmission.
Compatible receivers include nemi Connect (USB receiver for PC and Q.Station integration), nemi Log (field logger with GNSS and RTC), and nemi EdgeBase (autonomous gateway with LTE/5G, internal SSD, and GNSS). Compatible sensor nodes include the nemi G+ / ultra / nano (vibration/acceleration sensors) and the nemi DAQ / nano (multi-channel analog and digital data acquisition modules with IMU).
Typical Applications¶
nemi Link 2400 is designed for
- Structural health monitoring — bridges, buildings, towers, wind turbine rotor blades and similar structures, where nodes are distributed over distances up to 350 m and vibration, strain, or deformation data is collected continuously or intermittently.
- Rotating machinery measurements & condition monitoring — drivetrains, compressors, and pumps. The system tolerates challenging RF environments (metallic enclosures, continuously rotating antennas) through configurable radio modes and link adaptation.
- Multi-sensor field deployments — applications requiring time-synchronized data from heterogeneous sensor types (accelerations, vibrations, rotation rates, strain gauges, temperature and other analog signals) on a single radio network with microsecond-level synchronization.
- Long-term autonomous monitoring — when combined with the nemi EdgeBase or nemi Log, the system operates without a PC on site. Sensor nodes on battery run for months to years using batteries or solar power supply.
- Integration into existing data acquisition infrastructure — the nemi Connect USB receiver integrates with all existing PC technology via our available Python API and protocol documentation and with Gantner Instruments' Q.Station.
Technical Specifications¶
Radio Parameters¶
| Parameter | Value |
|---|---|
| Frequency band | 2.4 GHz ISM |
| Number of radio channels | 80 (channel numbers 0–79, default: channel 0) |
| Recommended channel separation for parallel networks | ≥ 10 channels (e.g. channels 0, 25, 50, 75) |
| Radio modes | 2 Mbit/s, 1 Mbit/s, 500 kbit/s, 125 kbit/s |
| Network topology | Star (TDMA) |
| Maximum sensor nodes per receiver | 8 |
| Time synchronization accuracy (sensor nodes to receiver) | ±10 µs with a stable radio connection |
| Timecounter resolution | 1 µs |
| Timecounter rate stability | ±50 ppm |
Range and Aggregate Bandwidth¶
| Radio Mode | Indoor Range | Urban / LOS Range | Theoretical range | Sum sampling rate (24-bit normalized) | Note |
|---|---|---|---|---|---|
| 2 Mbit/s | ~20 m | ~50 m | 300 m | 36 kHz | Highest energy efficiency |
| 1 Mbit/s | ~50 m | ~125 m | 750 m | 15 kHz | Balanced range and rate |
| 500 kbit/s | ~90 m | ~225 m | 1800 m | 8 kHz | Extended range |
| 125 kbit/s | ~140 m | ~350 m | 2100 m | 3 kHz | Longest range, lowest energy efficiency |
Use the nemi Link 2400 Radio Channel Calculator to check the radio channel load for your nodes and sampling rates — for every combination of radio speed and number of nodes.
Other modes than 2 Mbit/s require firmware ≥ 01.12.2023 on all devices in the network — receiver and every sensor node.
When changing radio mode in a deployed network: update the receiver first, then each sensor node. A node and receiver on different modes will not communicate.
Node Count Modes¶
| Mode | Max Nodes | Typical use case |
|---|---|---|
| 3-node | 3 | Higher per-node bandwidth, lower latency |
| 8-node | 8 | Maximum network capacity |
| 1-node (low-latency) | 1 | Minimum latency; maximum node-bandwidth |
Use 1-node low-latency mode when one node requires very high data rates (e.g., nemi G+ ultra at 26.666 kHz, or 6.4 kHz AD + 3,332 Hz IMU from a single nemi DAQ — approx. 38 % channel load in 1-node mode at 2 Mbit/s, but more than 100 % in 3-node mode) or when minimum end-to-end latency is required.
Radio Transmission Times per Packet¶
| Radio Mode | Transmission time (eg. 25-sample message) |
|---|---|
| 2 Mbit/s | ~0.88 ms |
| 1 Mbit/s | ~1.76 ms |
| 500 kbit/s | ~3.52 ms |
| 125 kbit/s | ~14.08 ms |
First Commissioning¶
Prerequisites¶
Before starting, prepare:
- Receiver: nemi Connect (USB/PC), nemi Log (stand-alone logger with USB/PC-receiver mode) or nemi EdgeBase (stand-alone gateway with logging mode 6 active)
- Sensor nodes: nemi G+ / ultra / nano, or nemi DAQ / nano with charged batteries or external supply
- Software: nemi Sensor Config (radio parameters of the nodes), nemi Studio or nemi Studio Web App for receiver configuration and live checks
- Network parameters: RF channel, radio speed, node count, node numbers
Core Radio Parameters¶
Configure these consistently on receiver and nodes:
| Parameter | Meaning |
|---|---|
| RF channel | 2.4 GHz channel used by one Link 2400 network |
| Radio speed | Range, bandwidth, and energy trade-off |
| Network size | 3-node, 8-node, or 1-node low-latency mode |
| Node number | TDMA slot used by a sensor node |
The Magic Triangle of wireless Sensor networks¶

When selecting settings for a wireless sensor network, the three parameters runtime, sampling rate, and range cannot be set independently of one another. If you want to increase the sampling rate, you must sacrifice either runtime or range, and vice versa. With nemi Link 2400, you can balance the sampling rate and range against one another to find the optimal configuration for your application.
Step 1 — Select Radio Mode¶
All devices in the network must use the same radio mode. Use the highest radio speed that still gives a stable link in the real installation. This maximizes sampling capacity and energy efficiency.
| Requirement | Recommended starting point |
|---|---|
| Highest sample rate, short distance | 2 Mbit/s |
| General indoor use | 1 Mbit/s |
| Longer distance, walls, partial shielding | 500 kbit/s XR |
| Maximum range, lower sample rates | 125 kbit/s XR |
| Minimum latency with one node | 1-node mode at the highest stable radio speed |
- Start with 2 Mbit/s or 1 Mbit/s as the default for most indoor and short-range applications.
- Switch to 500 kbit/s or 125 kbit/s for longer distances, wall or metal attenuation.
- Always select the fastest possible radio mode; this reduces power consumption
- Check whether the desired sampling rates are achievable with the selected transmission mode; use our nemi Link 2400 Radio Channel Calculator for this (it replaces the former Excel configuration tool)
Step 2 — Select RF Channel¶
The 2.4 GHz band is shared with WiFi, Bluetooth and other ISM-band devices. To minimize interference:
- Channel 0 is the default and a good choice for most installations.
- Other channels work as well; some of them (e.g. channel 10) may be slightly more affected by WiFi traffic than channel 0. Check the local 2.4 GHz environment (active WiFi networks) before fixing the channel.
- For up to four parallel nemi Link 2400 networks in the same area: use channels 0, 25, 50, and 75.
- Keep at least 10 channels between parallel networks. If more systems must operate in the same area, plan channels carefully and verify reception in the final installation.
All nodes and the receiver must be on the same channel.
Step 3 — Configure all sensor nodes according your selected RF settings¶
For all sensor nodes to be connected perform the following steps:

- Open our software nemi Sensor Config (> version 2.1)
- Turn off the sensor node
- Connect the sensor node to a USB port on your PC
- Turn on the sensor node, a new COM-Port should automatically show up in nemi Sensor Config
- You now have 10 seconds to connect to the sensor node via nemi Sensor Config (enter USB configuration mode) before it automatically enters radio transmission
- Click on "Connect COM-Port", the current radio settings of the sensor node are shown
- Enter the desired radio Settings
- Click on "Set nemi Link Parameters", the sensor node automatically resets
- To check the settings reconnect to the sensor node
- Disconnect the sensor node, turn it off and unplug it
- For configuring a new node click on "Clear Console" first and start again with step 2.
Step 4.1 — Commission nemi Connect (USB Receiver) or nemi Log (as USB receiver)¶
- Connect the nemi Connect / nemi Log to the PC via USB. It enumerates as a virtual COM port (USB CDC ACM).
- Open nemi Studio or the nemi Studio Web App and connect the COM port (see the respective software documentation for details). wirelessSensorPlot is no longer maintained.
- Confirm that the receiver sends debug and timing messages (look for
Waiting for Config Messages to start ...). - Configure the receiver: set radio mode, channel, and node count.
Step 4.2 — Commission nemi EdgeBase¶
Initial Network Access¶
- Connect a USB-C to Ethernet adapter to the nemi EdgeBase USB-C port.
- Plug an ethernet cable between nemi EdgeBase USB-C adapter and your PC.
- Set your PC IP address to 192.168.101.1, subnet mask 255.255.255.252.
- Access the EdgeBase at 192.168.101.2 via FTP:
- FTP user
nemibase_config— for YAML configuration files - FTP user
nemibase_data— for recorded measurement data - Use logging_mode: 6 to let the nemi EdgeBase act as remote nemi Connect
- See nemi EdgeBase documentation for more details
Step 5 — Verify Link Quality¶
- Power on sensor nodes. Each node must be configured with the same radio mode and channel, and a unique node number within the network size (1–3, 1–8, or 1 in low-latency mode).
- Start with all components near each other.
- Verify that all nodes appear in nemi Studio or the nemi Studio Web App with plausible signal strength and no missing samples.
- Move components step by step toward their final positions.
- If reception degrades (= latency starts to continuously increase, samples are missing, radio strength indicator drops): first improve antenna orientation and placement, then switch to a slower radio mode.
- Check if latency values do not continue rising (this would mean that not all samples can be transmitted with the given radio speed and connection strength)
Configuration Trade-Offs¶
- More active nodes reduce the per-node bandwidth and increase TDMA scheduling delay.
- Lower radio speed increases range but reduces aggregate sample capacity.
- Lower channel utilization improves robustness because retransmissions have more room. Check the channel load with the nemi Link 2400 Radio Channel Calculator.
Time Synchronization (Stage 1)¶
Once the network is running, sensor node clocks are automatically synchronized to the receiver via the radio protocol. No user action is required. With a stable radio connection, the synchronization accuracy is ±10 µs. The receiver handles its own downstream synchronization (Stage 2, e.g., GNSS on the nemi EdgeBase) independently — see Integration for details.
Mounting & Connections¶
Antenna Placement¶
The antenna of all nemi Link 2400 products has a toroidal (donut-shaped) radiation pattern — signal is strongest perpendicular to the antenna axis and weakest along the axis (end-on view).
- Keep all antennas in the same plane, oriented perpendicular to that plane rather than pointing antenna tips directly at each other.
- In rotating or moving applications (e.g., sensor nodes on rotating machinery), antenna orientation changes continuously. Position the receiver antenna where good connection time is maximized. At very slow rotating components: Use a slower radio mode to maximize link budget if samples cannot be transmitted and keep radio utilization low enough to tolerate temporary fades.
- In metallic enclosures (e.g., wind turbine rotor hubs): position the receiver antenna outside the enclosure or on its boundary. If an enclosure behaves as a Faraday cage, use two separate receiver networks — one inside, one outside — rather than forcing transmission through the shielded boundary. The same approach applies to reinforced concrete structures where inside-to-outside links can be poor.
Receiver Placement¶
Place the receiver as close as practical to the sensor group, with the fewest metallic or reinforced barriers between receiver and nodes. In installations with two distinct RF areas, use two receiver networks rather than one overextended network.
Multiple nemi Link 2400 networks can operate in the same area if they use separate RF channels with adequate spacing. Each network requires its own receiver.
Battery Life Planning¶
Example current draw (nemi G+ at 3.3 V):

| Operating mode | Current draw |
|---|---|
| 1000 Hz / 1 Mbit/s, continuous | ~5.84 mA |
| Deep sleep | ~0.01 mA |
| Intermittent: 30-second wake-up cycle | ~0.18 mA |
For long-term monitoring, intermittent (sleep/wake) operation dramatically extends battery life — a node waking every 30 seconds draws only ~0.18 mA on average, enabling multi-year runtime with a suitable battery pack.
Original Saft lithium primary cells are recommended for long runtime and reliable low-temperature performance. Please purchase only genuine cells and be aware that many counterfeit battery cells are available on the market!
Integration¶
Common Data Paths¶
| Use case | Typical path |
|---|---|
| Local PC acquisition | Sensor node(s) -> nemi Link 2400 -> nemi Connect -> USB virtual COM port -> PC software nemi Studio, nemi Studio Web App or Python API |
| Embedded Linux acquisition | Sensor node(s) -> nemi Link 2400 -> nemi Connect -> USB CDC ACM -> serial parser / Python API |
| Field logging | Sensor node(s) -> nemi Link 2400 -> nemi EdgeBase or nemi Log -> local files -> FTP/VPN download / upload |
| IoT telemetry | Sensor node(s) -> nemi Link 2400 -> nemi EdgeBase or nemi Log -> MQTT/cellular -> IoT platform / Dashboard |
| Gantner Instruments | Sensor node(s) -> Link 2400 -> nemi Connect -> USB -> Q.station with nemione plugin |
CAN bus via Gantner Q.station is generally not suitable for raw high-rate Link 2400 data because its data rate is too low for typical multi-channel radio streams. It may still publish reduced or resampled values over fieldbus.
USB Protocol Overview¶
The nemi Connect, nemi Log and the internal receiver of the nemi EdgeBase (when accessed via network in logging mode 6) expose a binary data stream with COBS (Consistent Overhead Byte Stuffing) framing.
We offer a Python API which does all message decoding and delivers Pandas dataframe queues. If you have already purchased products from us, please ask us for a download-link.
Key protocol properties:
- The receiver appears as a USB CDC ACM virtual COM port; no proprietary driver is required.
- All nemione® USB devices use the same binary messages. They are encoded with the COBS algorithm; a zero byte only appears as the delimiter between messages.
- After the COM port has been opened, the receiver sends info messages (human-readable debug output) and timing messages and waits for configuration. The host first sends the receiver configuration (radio channel, radio speed, network size) and then one configuration message per sensor node of the network (1, 3 or 8 — also for inactive nodes). nemi Studio, the nemi Studio Web App and the i4M Python API do this automatically.
- Afterwards the receiver forwards the data messages of all sensor nodes (measurement data, depending on the sensor type), info messages and timing messages.
A custom integration requires serial port access, splitting the stream at the zero-byte delimiter, COBS decoding, decoding of the individual messages and the time mapping via the timing messages.
The complete protocol documentation is provided to customers on request and is disclosed to customers by i4M.
Time Synchronization¶
Stage 1 — Within the nemi Link 2400 Network¶
Each sensor node maintains a Timecounter — a 1 MHz (1 µs resolution) clock that is continuously synchronized to the receiver's master clock via the radio protocol. All data messages include the Timecounter at the moment of measurement / sampling of the last sample in the message.
- Sync accuracy: ±10 µs with a stable radio connection
- Rate stability: ±50 ppm
- Timecounter rollover: after 2³² µs ≈ 71.6 minutes
Synchronization is automatic and continuous. No user configuration is required for Stage 1. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long; synchronization then relies on fewer events and its accuracy decreases. A stable radio link (good antenna placement, suitable radio mode, moderate channel utilization) is therefore also the basis for precise time synchronization.
Stage 1 synchronization is independent of GNSS or NTP: a time reference at the receiver does not improve the synchronization between a node and its receiver, it provides the absolute time anchor (Stage 2).
Timing Messages and Custom Time Mapping¶
The receiver regularly sends timing messages with its current radio network time. They are used to map the radio network time (Timecounter) to the time base of the host.
For custom software, build a linear relation between Timecounter and host or UNIX time, reject outliers caused by USB or operating-system scheduling jitter, and update the model continuously to follow the clock drift. Do not use USB arrival times as sample times.
Stage 2 — Receiver to External Time Reference¶
The receiver handles its own downstream time synchronization independently of Stage 1:
- nemi Connect, nemi Log in USB receiver mode, nemi EdgeBase in logging_mode 6 → synchronizes to the connected host PC clock or to the Q.Station clock via timing messages.
- nemi Log → synchronizes to GNSS/GPS or internal RTC.
- nemi EdgeBase → synchronizes to GNSS/GPS or NTP via local or cellular network.
Multi-Receiver Time Alignment¶
For deployments with multiple receivers where globally aligned timestamps are needed:
- Use GNSS on both nemi EdgeBase / nemi Log units for autonomous field installations.
- Use NTP for installations with reliable network connectivity.
Resampling to a Common Time Axis¶
Each sensor node produces data at its own rate with its own Timecounter-based timestamps. Nodes do not force their samples onto identical time instants, even at the same nominal ODR — nemi Link 2400 transmits raw data with native timestamps and avoids hidden interpolation. To create a synchronized multi-channel time axis:
- Resample all streams to a common rate using interpolation on the RTC/NTP or GNSS synched timestamps.
- The Gantner Q.Station plugin performs this resampling automatically.
- For post-processing of binary recordings from the nemi EdgeBase, use the provided resampling script, which applies a smooth linear clock drift correction.
- In nemi Studio use the "Resample Data" feature which automatically resamples all data streams to a common timestamp.
Gantner Q.Station Integration¶
Connect the nemi Connect via USB to a Gantner Q.Station and use the nemione/i4M plugin:
- The plugin handles the USB protocol and presents nemi Link 2400 channels as Q.Station input channels.
- Internal resampling aligns nemi timestamps to the Q.Station clock model.
- Multiple nemi Connect receivers can be connected to one Q.Station for multi-network deployments.
- For high aggregate rates, verify the total controller load including other wired inputs. If the plugin or controller becomes the bottleneck, reduce sample rates or active channels, or split the system across multiple receivers.
EdgeBase and IoT Integration¶
For field deployments without a measurement PC, the nemi EdgeBase or nemi Log receive the nemi Link 2400 data and provide downstream services: binary or CSV recording, FTP access to configuration and data, LAN / VPN / cellular access and MQTT transmission. MQTT is best suited for status values, aggregated values and low-to-medium-rate streams; continuous high-rate raw data is better handled as binary files with later download and decoding.
Python / Custom Integration¶
The USB protocol is documented and disclosed to customers on request. Any environment with serial port access can integrate with nemi Link 2400:
- No proprietary driver is required beyond the standard USB CDC ACM class driver.
- Python on Linux: USB CDC ACM is built into the Linux kernel; use
pyserialor equivalent. - i4M offers a Python API which connects to a nemi Connect and provides all node data via Pandas dataframe queues. Ask i4M for a download link if you are already user of nemione products.
Signal Latency¶
Total latency from physical event to decoded value at the host has four additive components:
| Component | Typical range |
|---|---|
| Analog → ADC conversion | Microseconds |
| Sample buffering (N samples before TX) | N / ODR (e.g., 25 samples at 1000 Hz = 25 ms) |
| TDMA slot wait (worst case, 8-node) | ~87.5 ms |
| Packet transmission time | ~0.88 ms (2 Mbit/s) to ~14 ms (125 kbit/s) |
| Retransmissions | Additional packet transmission times when packets must be repeated |
| Host/plugin processing | Depends on receiver and downstream system |
Total: 1–3 ms (1-node, 2 Mbit/s, low buffer) to ~100 ms or more (8-node, 125 kbit/s, full buffer).
For applications where latency is critical: use 1-node low-latency mode at 2 Mbit/s and a high data rate.
Troubleshooting¶
Radio / Connection Issues¶
No sensor data appears after opening the COM port¶
Causes: Receiver awaiting Config message; radio mode or channel mismatch between node and receiver; node number outside configured network size; firmware mismatch.
Fix:
- Confirm the receiver enumerates as a USB CDC ACM virtual COM port.
- Look for debug messages (
Waiting for Config Messages to start ...). - Configure the receiver first: radio mode, channel, node count.
- Configure each sensor node with the same radio mode and channel, and a unique node number.
- For 1 Mbit/s, 500 kbit/s and 125 kbit/s modes: verify firmware ≥ 01.12.2023 on all devices.
Unstable link or insufficient range¶
Causes: Antenna misalignment or shielding by metal or concrete; radio mode too fast for the geometry; 2.4 GHz interference; high channel utilization leaving little time for retransmissions.
Fix:
- Test close to the installation first to verify that all radio parameters are correct and the radio link works at short range.
- Align antennas in the same plane, perpendicular to that plane.
- If samples are still missing: Step down radio mode: 2 Mbit/s → 1 Mbit/s → 500 kbit/s → 125 kbit/s.
- Reduce aggregate sample rate or number of active channels to lower channel utilization; check the channel load with the nemi Link 2400 Radio Channel Calculator.
Different timestamps between nodes at the same nominal rate¶
Cause: Each node samples independently; sample instants are not forced to be identical, even at the same nominal ODR. The Timecounter timestamps reflect when each sample was actually taken.
Fix: Resample all streams to a common time grid using cubic spline interpolation. For Gantner integration, the plugin handles this automatically.
High latency / slow data delivery¶
Cause: TDMA frame wait in 8-node mode can add up to ~87.5 ms; combined with buffering and transmission time, total latency can exceed 100 ms.
Fix:
- Switch to 1-node low-latency mode.
- Use 2 Mbit/s to minimize per-packet transmission time (~0.88 ms).
Further Symptoms¶
| Symptom | Likely cause | Resolution |
|---|---|---|
| 500 kbit/s or 125 kbit/s mode does not work | Not all devices have firmware ≥ 01.12.2023 | Update the receiver and all nodes to compatible firmware |
| Link works inside one area but not through a wall, hub, nacelle or concrete boundary | RF shielding | Place the receiver in the same RF area or use separate networks |
| Missing samples at high DAQ nano rates | AD frontend and IMU together exceed the available radio capacity | Use 1-node mode at 2 Mbit/s, reduce rates or channels, or split AD and IMU across two nodes |
| Timestamps show 1970-01-01 | Downstream time anchor of the receiver (GNSS / NTP / RTC) not yet available | Wait for the time synchronization of the receiver; reconstruct timing from the Timecounter |
| Multiple receivers are not aligned to each other | Stage 2 synchronization not configured or not available | Use GNSS or NTP on the receivers (or one NTP-synchronized PC) and verify the alignment |
| USB arrival times are jittery | Host OS and USB scheduling jitter | Use the timing messages and the Timecounter mapping, not the arrival time, as sample time |
| Q.Station or plugin becomes unstable | Downstream controller load too high | Reduce sample rates, reduce node count, or split across receivers |
Product Changes¶
| Date | Change |
|---|---|
| October 2022 | Telemetry message split: telemetry systems delivered from 01.10.2022 send separate messages for the AD frontend, the IMU and the digital inputs, each at its native sampling rate; older systems use one combined telemetry message. Parsers that support old and new hardware must handle both generations (the i4M decoders do). |
| December 2023 | Firmware from 01.12.2023: 500 kbit/s and 125 kbit/s radio modes, receiver configuration with radio speed and network size, 1-node low-latency mode. Update all devices in a network together. |
FAQ¶
Applications¶
Q: What measurement types is the nemi Link 2400 designed for? A: Dynamic vibration and acceleration (nemi G+, nemi G+ nano), multi-channel analog signals including strain gauges, 0–10 V sensors, Pt100 temperature, and digital/pulse inputs (nemi DAQ, nemi DAQ nano). The nodes also provide a 9 DoF IMU (accelerometer, gyroscope, magnetometer).
Q: Can the nodes be used for orientation and attitude estimation? A: Yes, using the nodes' internal 9 DoF IMU. For pure attitude estimation, use the ±2 g accelerometer range — at 16-bit resolution, ~0.1° dynamic accuracy is achievable. The magnetometer provides a heading reference but is sensitive to magnetic distortions in metallic environments.
Q: Is nemi Link 2400 suitable for closed-loop control? A: With limitations. The system delivers microsecond-resolution timestamps, but TDMA scheduling and wireless retransmissions under poor radio conditions introduce variable latency (1–100+ ms). Use 1-node low-latency mode at 2 Mbit/s, and validate end-to-end latency in the target configuration before committing to a control application.
Q: Is GNSS available directly inside a sensor node? A: No. GNSS is available only at the receiver level (nemi EdgeBase, nemi Log). For position or speed measurement at the node level, use an external sensor (optical, ultrasonic, tactile, barometric pressure etc.) connected to the nemi DAQ.
Q: Can nemi Link 2400 be used in wind turbine rotor applications? A: Yes. Use the slow radio modes (500 / 125 kbit/s) to maximize link budget and tolerate brief connection gaps during rotation. Position the receiver antenna outside or at the boundary of the metallic hub. For installations with both hub and nacelle sensors, use two separate nemi Link 2400 networks and receivers.
Connectable Sensors¶
Q: Which sensor node should I use for high-quality vibration measurement? A: For low to medium bandwidths the nemi G+ / nano. For higher bandwisths the nemi G+ ultra / nano. The nemi G+ dedicated MEMS accelerometer has approximately 16× lower noise than the IMU accelerometer channel on the nemi DAQ / nano, making it the preferred choice for precision vibration measurements. For high-dynamic and high-bandwidth measurements the nemi G+ ultra / nano can be used up to 26.6 kHz ODR.
Q: Can I measure displacement using the accelerometer? A: No. Double integration of acceleration to displacement accumulates offset errors quadratically — even a very small accelerometer offset produces unbounded displacement drift. Use dedicated displacement sensors (LVDT, potentiometric, magnetostrictive, optical flow, barometric pressure) with analog or digital output connected to the nemi DAQ.
Q: Can I connect a TTL pulse sensor for speed or velocity measurement? A: Yes, via the nemi DAQ digital inputs. The fixed sampling rate is 2000 Hz (Nyquist limit: 1000 Hz maximum pulse rate). Calculate the maximum expected pulse frequency at the target speed and verify compatibility before deploying. Higher scan rates of the digital inputs can be realized upon request.
Q: Can I measure structural deformation (strain gages) and temperature (Pt100) on the same structure? A: Yes, but not on the same nemi DAQ unit — Strain gages and Pt100 cannot be active simultaneously on one unit. Use two nemi DAQ units (one for strain gages, one for Pt100), both connected to the same nemi Link 2400 network.
Q: Can I connect a geophone or low-level analog sensor? A: Yes, via the nemi DAQ 0–10 V input with an external signal conditioning circuit to bring the signal into the 0–10 V input range.
Battery Life¶
Q: How long will sensor node batteries last?
A: Use Runtime (h) ≈ 0.9 × capacity (mAh) / current (mA). Ask i4M for current consumption at your operating point. E.g.: At 1000 Hz / 1 Mbit/s continuous, a nemi G+ draws ~5.84 mA. In intermittent mode (30-second wake-up cycle), average draw is ~0.18 mA — enabling multi-year operation with a suitable battery pack. Use Saft lithium primary cells for long runtime and reliable low-temperature performance.
Q: Does reducing sampling rate always improve battery life? A: Reducing rate helps, but radio speed, continuous vs. intermittent operation, and sleep behavior are equally important. Intermittent (sleep/wake) operation is the most effective lever for long-term monitoring deployments.
Range¶
Q: What is the maximum wireless range? A: Up to ~350 m line-of-sight at 125 kbit/s. Indoor ranges are shorter due to wall and structural attenuation. Field deployments exceeding 300 m have been achieved at 500 kbit/s under good line-of-sight conditions or inside tubes or the bridge box girder.
Q: Can I extend range with a WiFi repeater? A: No. nemi Link 2400 uses a proprietary protocol; WiFi repeaters only relay WiFi traffic. For longer range, use the 125 kbit/s mode or deploy a second receiver network at the needed distance.
Q: How many parallel nemi Link 2400 networks can operate in the same area? A: Four networks comfortably fit with channels 0, 25, 50, and 75. More networks are possible with careful channel planning, keeping at least 10 channels between any two concurrent networks.
Q: Which radio channel should I use? A: Channel 0 is the default and a good choice. Other channels work as well; channels such as channel 10 are slightly more exposed to potential WiFi interference than channel 0. All nodes and the receiver of one network must use the same channel.
Integration¶
Q: Can I parse the USB data myself?
A: Yes. The protocol documentation (COBS-framed binary messages over USB CDC ACM) is provided to customers on request. Alternatively, use the i4M Python API, which delivers all node data as pandas DataFrame queues.
Q: Can I integrate nemi Link 2400 with a Gantner Instruments Q.Station? A: Yes. Connect the nemi Connect via USB and use the nemione plugin. The plugin handles the binary protocol and automatically resamples nemi timestamps to the Q.Station data streams using interpolation.
Q: Is there a REST API for the nemi EdgeBase? A: No. The EdgeBase exposes FTP for configuration and data file access, and MQTT for live data streaming. Raw data access uses the USB binary protocol or binary file download via FTP.
Q: Can I receive data on a Raspberry Pi or embedded Linux system?
A: Yes. The nemi Connect is a standard USB CDC ACM device. Any Linux system with Python and pyserial (or equivalent) can receive and parse the binary protocol without additional drivers.
Q: What is the maximum aggregate data throughput? A: At 2 Mbit/s, up to ~36 kHz aggregate sample bandwidth (normalized to 24-bit) across all nodes. USB 2.0 is not the bottleneck — radio bandwidth and TDMA scheduling are the limiting factors.
Q: How accurate is time synchronization between nodes? A: ±10 µs with a stable radio connection. With a poor connection, some synchronization events are discarded because their transit time is too long, and the accuracy decreases. Rate stability is ±50 ppm.
Q: What is GNSS or NTP on the nemi EdgeBase or nemi Log used for? A: It provides the absolute time anchor (Stage 2) and aligns multiple receivers to each other. It is separate from the radio-network synchronization (Stage 1) that keeps the sensor nodes locked to their receiver.
Q: Does a lower radio speed always improve battery life? A: No. Lower speeds increase range but reduce the energy efficiency per delivered sample. Use the highest radio speed that is stable in the installation.
Q: Can I build my own time synchronization software? A: Yes. The timing messages of the receiver provide the Timecounter-to-host-time mapping needed to implement a linear synchronization model (details in the protocol documentation, provided to customers on request). No NDA is required for this approach. Access to nemi's deeper proprietary synchronization algorithms requires an NDA and development engagement.