nemi G+ is a compact wireless sensor for measuring accelerations, vibrations, rotation rates, magnetic fields and temperature. It integrates a high-resolution triaxial capacitive MEMS accelerometer (up to 4,000 Hz), a 9-DoF IMU (3-axis accelerometer, gyroscope and magnetometer), an internal rechargeable lithium-ion battery and the proprietary nemi Link 2400 radio interface — all in a housing of 31.6 × 31.6 × 22.3 mm and approximately 50 g (stainless steel base, standard) or 30 g (aluminum base). Radio ranges of up to 350 m are possible.

The product is intended for applications where cables are difficult, unsafe or mechanically intrusive: rotating shafts, moving machine parts, ride vehicles, SHM installations, temporary test installations and compact condition-monitoring setups.

Three primary MEMS hardware variants are available: M08 with selectable ranges up to ±8 g, M40 with selectable ranges up to ±40 g and M256 with selectable ranges up to ±256 g. All variants carry the same secondary IMU, magnetometer and temperature sensor.

nemi G+ requires a compatible nemi Link 2400 receiver to transmit data: nemi Connect (USB receiver for PC or Gantner Q.Station), nemi Log (compact SD-logger with cellular option), or nemi EdgeBase (autonomous field gateway with 4G, edge computing, and local SSD storage). All three receivers share the same star-topology radio architecture: one receiver per radio channel, up to eight sensor nodes per channel. The receiver handles data access, storage, downstream integration and time synchronization to host or external time sources.

Data can be transmitted as live raw samples or as pre-evaluated "smart data" computed by the onboard 64 MHz 32-bit MCU. Edge computing can be realized upon request in bilateral development projects. It reduces radio load, storage volume and power consumption in long-term monitoring scenarios. For permanent installations, the 5–30 V DC wide-range voltage input enables continuous operation without battery management.


Typical Applications

  • Portable test measurements — rapid, cable-free installation for short-duration tests in locations where cabling is impractical.
  • Condition monitoring on rotating machinery — wind turbine main shafts, pitch bearings, gearboxes and production machines. No slip rings or cables are required because the sensor is fully self-contained.
  • Structural health monitoring (SHM) — bridges, towers, suspended structures and other civil engineering assets. The MEMS measures down to DC (static gravity), enabling simultaneous tilt and vibration capture from a single sensor.
  • Amusement ride and vehicle dynamics — roller coasters, water rides, rail vehicles and other moving platforms. Data is transmitted live during in receiver range and buffered internally when the vehicle passes out of radio range.
  • Long-term vibration monitoring — predictive maintenance campaigns on production machinery, where low to moderate sampling rates allow multi-week battery operation or continuous operation from an external DC supply.
  • Tilt and inclination monitoring — quasi-static inclination change monitoring on structures, bridges and geotechnical installations. Use the M08 variant at ±2 g with low sampling rate and calibration.
  • Shock and high-g measurements — impacts, drop tests and high-rpm rotating parts with accelerations beyond ±40 g. Use the M256 variant with ranges up to ±256 g.

Technical Specifications

General

Parameter Value Unit
Dimensions 31.6 × 31.6 × 22.3 mm
Weight approx. 50 (stainless steel base, standard) / approx. 30 (aluminum base) g
Housing protection class IP41 standard; IP67 weather-resistant on request —
Radio range up to 350 m
Operating temperature −20 to 60 °C
Onboard MCU 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, hardware crypto —

Dimensions of nemi G+

Power Supply

Parameter Value Unit
Internal battery 1-cell lithium-ion rechargeable —
Battery runtime at 4,000 Hz (all three primary axes active) > 10 h
Battery runtime at reduced sampling rates several days, depending on configuration —
Charging time (0–100 %) approx. 3 h
USB power (charging and configuration) 5 (micro-USB) V
Wide-range voltage input 5–30 DC V
Low-power option: direct supply input (factory option) 3.3–5 DC V

Primary MEMS Accelerometer

Parameter Value Unit
Sensor type High-resolution triaxial capacitive MEMS accelerometer -
Selectable sampling rates 4,000 / 2,000 / 1,000 / 500 / 250 / 125 Hz
Realizable −3 dB bandwidths 800 / 500 / 250 / 125 / 62.5 / 31.25 Hz
Sampling-rate stability (full temperature range) ± 50 ppm
Non-linearity (related to measuring range) 0.1 %
Cross-axis-sensitivity 1.0 %
Static 3D inaccuracy without calibration < 8 % of range
Static 3D inaccuracy with factory calibration (on request) < 0.1 (M08) / < 1.0 (M40, M256) % of range
M08 variant — selectable ranges ± 8 / 4 / 2 g
M08 variant — sensor resonance frequency 2,400 Hz
M08 variant — signal resolution 20 bit
M40 variant — selectable ranges ± 40 / 20 / 10 g
M40 variant — sensor resonance frequency 5,500 Hz
M40 variant — signal resolution 20 bit
M256 variant — selectable ranges ± 256 / 128 / 64 / 32 / 16 / 8 / 4 / 2 g
M256 variant — sensor resonance frequency 2,400 Hz
M256 variant — signal resolution 16 bit

The M08, M40 and M256 variants use different primary acceleration measuring ranges. Select the hardware variant according to the maximum expected acceleration, then choose the smallest configured range that leaves enough headroom for the actual signal.

M256 variant

In the ranges from ±32 g upwards, the M256 main sensor uses a separate high-g element whose zero offset can be several tenths of a g. Use Node Zero and Scaling in nemi Studio to compensate the offset if required. The extended ranges are offered in nemi Studio only after the sensor node has reported the matching hardware.

Frequency Responses

Frequency response ± 8 g variant Frequency response ± 40 g variant
Frequency response ± 8 g variant Frequency response ± 40 g variant

Noise figures

Sampling Rate in Hz RMS Noise in milli-g (8 g variant @ 2 g range) RMS Noise in milli-g (40 g variant @ 10 g range)
125 0.178 0.593
250 0.252 0.839
500 0.356 1.186
1000 0.503 1.677
2000 0.712 2.372
4000 1.006 3.354

Secondary 9-DoF IMU (ACC / GYR / MAG)

Parameter Value Unit
Sensor type 9 DoF MEMS IMU, 3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer -
Sampling rate 1/25 of primary rate (e.g. 160 Hz at 4,000 Hz primary) Hz
Signal resolution 16 bit
IMU accelerometer ranges ± 16 / 8 / 4 / 2 g
IMU gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
IMU magnetometer ranges ± 16 / 12 / 8 / 4 Gauss

Internal Temperature Sensor

Parameter Value Unit
Sampling rate 1/25 of primary rate Hz
Measuring range −20 to 60 °C
Resolution 0.1 °C
Parameter Value
Frequency band 2.4 GHz
Topology Star (one receiver per channel)
Max. sensor nodes per channel 8
Compatible receivers nemi Connect, nemi Log, nemi EdgeBase

First Commissioning

Required Hardware and Software

Item Purpose
nemi G+ sensor Sensor node
nemi Connect / nemi EdgeBase / nemi Log Receiver
Micro-USB cable (data-capable, not charge-only) USB configuration and charging
nemi Sensor Config v2.1 or later Radio and node configuration via USB
nemi Studio v1.1 or later (Windows) or nemi Studio Web App (browser) Live display, sensor configuration and CSV recording

nemi Sensor Config and nemi Studio are provided to customers via download links (the software is not publicly available). The nemi Studio Web App runs in Chrome or Edge at https://nemi.one/studio/ and requires no installation.

Step 1 — Power / Charge the Sensor

Connect the sensor via micro-USB to a PC or USB charger before first use. The solid red LED indicates charging is in progress; the red LED turning off indicates a full battery. On some variants a green LED indicates a full charge. A full charge from 0 % takes approximately 3 hours but is not needed for first tests. If the sensor will run from external power, connect the wide-range input only to a DC supply within the specified voltage range (5–30 V DC).

Step 2 — Configure the Sensor via USB

Radio parameters (channel, radio mode, node number, maximum nodes) are persistent settings written via our software nemi Sensor Config over USB:

Screenshot of nemi Sensor Config 2.1

  1. Leave the power switch of the nemi G+ in the OFF position.
  2. Connect the micro-USB cable to the PC. Confirm it is a data-capable cable — power-only cables charge the sensor but do not transmit data. The cable delivered together with the sensor is data-capable.
  3. Launch nemi Sensor Config.
  4. Switch the sensor ON. The LED briefly cycles white → green → red → blue (restart), then shows solid green + flashing yellow (USB detected; waiting for COM port).
  5. nemi Sensor Config automatically shows the new sensor node and its COM port, which is selected automatically in the drop-down menu. Click Connect COM-Port in nemi Sensor Config within approximately 10 seconds after powering the sensor. Otherwise it enters radio transmission mode. The LED changes to solid green + flashing blue (COM port open; awaiting settings).
  6. Enter the radio parameters from the table below and click Set nemi Link Parameters.
  7. The sensor prints its new radio parameters to the console and the COM port connection is closed automatically. After 10 s of waiting for a new USB COM-Port connection the sensor will start into radio transmission mode with the new parameters. If it finds a receiver, it will start transmitting data.

Recommended first-test radio settings:

Parameter Recommended value Notes
nemi Link 2400 Mode 2 Mbit/s Required for 4,000 Hz with 3 nodes (with 1 node, 1 Mbit/s is also sufficient); adequate range for bench tests.
nemi Link 2400 Node Count 1 or 3 Increase to 8 sensors if needed but max. sampling rate is reduced!
nemi Link 2400 Channel 0 (other preferred channels are 25, 50, 75) Default; avoids busy Wi-Fi subbands.
nemi Link 2400 Node Number 1 Unique per sensor on the same channel. Assign 2, 3, … for additional sensors.

For sites with multiple independent radio networks, use channels separated by at least 10 (e.g. channel 0 and channel 10) to minimize inter-channel interference. Channel 0 is the default and the first choice; channel 10 works as well, but is slightly more exposed to potential WLAN interference.

For more information regarding our radio network: nemi Link 2400

Step 3 — Set Up the Receiver and Verify Data

With nemi Connect or nemi Log in USB-Receiver mode:

  1. Launch nemi Studio or open the nemi Studio Web App in Chrome or Edge.
  2. Plug the nemi Connect into a USB port on the PC. nemi Studio detects the nemi Connect and selects its COM port automatically (in the Web App, click Connect and select the port in the browser dialog).
  3. Click Connect COM-Port, set the radio settings matching the sensor and click Start Receiver. See nemi Studio and nemi Studio Web App for details.
  4. Power on the nemi G+ without connected USB cable. Within a few seconds, live sensor data should appear in the software. Check the signal strength indicator to see if range is sufficient. If the signal strength indicator is low check for increasing latency of the incoming data and for missing samples.
  5. Set the sampling rate and measurement range wirelessly in nemi Studio and click Update Node Settings.
  6. View the live data or start a short CSV recording to verify data before mounting the sensor at its final location.

With nemi Log: The nemi Log is a standalone data logger with cellular option that requires no PC during operation. Initial configuration is done via CSV files (see Detailed Configuration). Once the nemi Log is configured and powered, the nemi G+ pairs automatically when channel and radio mode match.

With nemi EdgeBase: The nemi EdgeBase is a standalone field gateway requiring no PC during operation. Initial configuration is done via YAML files (see Detailed Configuration). Once the nemi EdgeBase is configured and powered, the nemi G+ pairs automatically when channel and radio mode match. Use EdgeBase logging_mode 6 to connect nemi Studio to the nemi EdgeBase over the network (TCP port 9413) to check live data, or open the nemi Studio Web App served by the EdgeBase in a browser (EdgeBase units produced before November 2026 need a software update for the Web App, which i4M installs remotely on request).

Before finalizing installation, use the nemi Link 2400 Radio Channel Calculator (online tool) to verify that the planned combination of sensors, sampling rates, active channels and radio mode fits within the channel bandwidth. Do not rely on intuition for bandwidth estimates; use the calculator.

First Data Transmission — Checklist

  1. Confirm receiver is connected and powered and on the same channel, radio mode and node count as the sensor.
  2. Confirm each sensor has a unique node number on the shared channel.
  3. Verify live data, signal strength and latency in nemi Studio or the nemi Studio Web App.
  4. Test at the intended installation location — do not hold the sensor in your hand during range tests; human body tissue strongly absorbs 2.4 GHz radio transmissions.

LED Status Codes

LED pattern Meaning
Rapid flash: white → green → red → blue Sensor restart
Solid red Battery charging via USB or wide-range voltage input
Red no longer continuously lit Battery fully charged
Solid green + flashing yellow USB data connection detected; waiting for COM port to open
Solid green + flashing blue COM port open; waiting for RF parameters or settings
Short red flashes (~2 s) Actively sampling and transmitting measurement data
Short green flashes every 10 s Sleep mode
Short blue flashes (~1 s) Time synchronization with wireless network
Green LED on continuously (in wireless mode) Internal ring buffer 80 % full — data cannot be transmitted fast enough; risk of data loss

Range Considerations

nemi Link 2400 operates at 2.4 GHz. Typical line-of-sight ranges by radio mode:

Radio mode Typical range (in buildings - in urban environment) Max live sampling rate (with max. 3 active sensors on the radio channel)
2 Mbit/s 20 - 50 m 4,000 Hz
1 Mbit/s 50 - 125 m 2,000 Hz
500 kbit/s 90 - 225 m 1,000 Hz
125 kbit/s 140 - 350 m 250 Hz

Range is strongly affected by antenna placement, metal shielding, human body absorption and obstructions. Do not perform a range test while holding the sensor in your hand. Mount it at the intended position, place the receiver antenna as it will be used in service, and test the actual sampling rate and node count. Under favorable line-of-sight conditions, ranges of several hundred meters are possible, but the reliable range must always be validated on site.


Mounting & Connections

Mechanical Mounting

nemi G+ has an M4 thread in the base and supports four mounting methods:

Mechanical mounting options

Method Suitability Notes
M4 grub screw Best vibration transmission Preferred for dynamic measurements and frequency analysis
Adhesive Practical for smooth, accessible surfaces Use surface preparation; verify the adhesive does not soften the vibration coupling path
Glued mounting plate Good for removable or curved-surface installations Ensure the plate is rigid and tightly coupled
Magnet Fast temporary mounting on ferromagnetic surfaces Affects the integrated magnetometer; do not use when heading/yaw data is required

Mounting material (e.g. adhesive, mounting plates, magnets) is not included; it is only supplied as an option if ordered.

Vibration transmission: For frequency analysis, mechanical stiffness between sensor and structure matters as much as sensor specification. A soft adhesive layer, loose screw or flexible bracket can dominate the measured frequency response at higher frequencies.

Axis orientation: The sensor X, Y and Z axes are printed on the housing. Document and photograph the mounting orientation during installation — axis confusion is a frequent source of data mismatch in multi-sensor comparisons.

Power Connections

Powering options on nemi G+

nemi G+ can be powered in three ways:

  1. Internal rechargeable battery — suitable for temporary installations and battery-powered monitoring.
  2. 5 V micro-USB — for charging and USB configuration. Sensor can also operate while connected.
  3. 5–30 V DC wide-range voltage input — for permanent installations. Two terminals on the side of the housing: + (positive supply) and - / GND (ground). External power also charges the internal battery when connected.

Observe supply polarity. The wide-range input uses a two-pole terminal connector next to the power switch (see dimension drawing).

Low-power option (factory option): Instead of the wide-range input, a 3.3–5 V supply input connected directly to the circuit is available. It is intended for customers who want to connect a battery within this voltage range (e.g. a lithium primary cell) and need maximum efficiency, as it saves the voltage converter.

External Sensors

nemi G+ has no external sensor interface. It contains its own MEMS accelerometer, IMU, magnetometer and temperature sensor. For connecting external analog sensors, strain gauges or other transducers, use the nemi DAQ product family.

Antenna

The internal antenna emits most strongly through the plastic cover side of the housing. Orient the sensor so the plastic cover faces the receiver whenever possible. For installations inside metal enclosures or structures, use the nemi G+ nano variant: all nano boards have a u.FL connector for an external 2.4 GHz antenna that can be routed to the outside.


Detailed Configuration

Configuration is split into two layers:

  • Persistent radio settings — written via nemi Sensor Config over USB (channel, radio mode, node number, max nodes).
  • Runtime measurement settings — set wirelessly via nemi Studio, the nemi Studio Web App or via nemi EdgeBase YAML files or nemi Log configuration CSVs (sampling rate, ranges, IMU channels, trigger parameters).

Configuration Tools Reference

Tool Connection Configures
nemiSensorConfig v2.1+ USB (micro-USB) Radio channel, radio mode, node number, max nodes per channel
nemi Studio via nemi Connect, nemi Log (USB receiver mode) or nemi EdgeBase Sampling rate, measurement ranges, sleep mode, continuous or intermittent transmission mode, zero and scaling
nemi Studio Web App via nemi Connect (Web Serial) or nemi EdgeBase (network) Sampling rate, measurement ranges, sleep mode, continuous or intermittent transmission mode
nemi Link 2400 Radio Channel Calculator Online tool (replaces the former Excel configuration tool) Validates that sampling rates fit within channel bandwidth for given radio mode and node count
nemi EdgeBase YAML config files VPN / FTP Sampling rate, measurement ranges, trigger parameters, logging intervals, MQTT settings, sleep/wake schedules
nemi Log CSV config files SD Card / FTP Sampling rate, measurement ranges, trigger parameters, logging intervals, sleep/wake schedules

Sampling Rate

Sampling rate −3 dB bandwidth Typical use
4,000 Hz 800 Hz Highest-bandwidth vibration and impact measurements
2,000 Hz 500 Hz Dynamic measurements not requiring full 800 Hz
1,000 Hz 250 Hz Rotating machinery and structural vibration below ~250 Hz
500 Hz 125 Hz Medium-bandwidth monitoring; reduced radio and power load
250 Hz 62.5 Hz Slow structural dynamics and tilt monitoring
125 Hz 31.25 Hz Lowest standard rate; tilt, inclination and minimum power

The IMU and temperature channels always operate at 1/25 of the primary rate (e.g. 160 Hz IMU at 4,000 Hz primary). This coupling is fixed in current firmware; future firmware versions are expected to allow independent IMU sampling rates.

Choose the rate from the required signal bandwidth; lower rates reduce radio load, data volume and power consumption.

Measurement Ranges

Always select the smallest range that avoids clipping. A wider range reduces effective resolution for small signals.

Sensor Available ranges Selection guidance
Primary accelerometer M08 version ±2 / 4 / 8 g Use ±2 g whenever the signal stays below 2 g; gives lowest noise (~22.5 µg/√Hz) and highest resolution (~3.9 µg/LSB)
Primary accelerometer M40 version ±10 / 20 / 40 g Use for shocks, impacts, high-rpm rotating parts or unknown peak amplitudes
Primary accelerometer M256 version ±2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 g Use for severe shocks and very high accelerations; from ±32 g a separate high-g element is used
IMU accelerometer ±2 / 4 / 8 / 16 g Useful for orientation and moderate-precision dynamic motion
IMU gyroscope ±125 / 250 / 500 / 1,000 / 2,000 / 4,000 °/s Select above the expected peak rotation rate
IMU magnetometer ±4 / 8 / 12 / 16 Gauss Enable only when the magnetic environment is suitable for heading use

For metrology-grade applications, request factory calibration at order time. Calibration reduces the static 3D inaccuracy of the primary MEMS from < 8 % to < 0.1 % (M08) or < 1.0 % (M40, M256) of the measuring range.

M256 Variant — Range Configuration

The main sensor of the nemi G+ M256 has a low-g and a high-g element. For compatibility, the M256 behaves like a nemi G+ M08 towards receivers and software (same configuration message, same data message, same 20-bit raw values); only the range codes 3–7 are new:

Range code M08 M40 M256 M256 element
0 ±2 g ±10 g ±2 g Low-g
1 ±4 g ±20 g ±4 g Low-g
2 ±8 g ±40 g ±8 g Low-g
3 — — ±16 g Low-g
4 — — ±32 g High-g
5 — — ±64 g High-g
6 — — ±128 g High-g
7 — — ±256 g High-g
  • At every (re)start, the nemi G+ reports its main sensor type. nemi Studio offers the range codes 3–7 only after the node has reported itself as M256. Codes 3–7 must only be sent to an M256; M08 and M40 do not support them.
  • The data message contains no range information: the receiver side must remember the range code last sent to the node and convert the raw values accordingly (nemi Studio works this way).
  • The integrated IMU of the M256 supports IMU accelerometer ranges up to ±16 g.
  • Conversion factors and the decoding of the extended ranges are provided by i4M with the protocol documentation. Note: the ±256 g stage uses 10.417 mg/LSB, so its arithmetic full scale is approx. ±341 g; the label remains "256 g".

Radio Mode, Channel and Node Configuration

Radio mode Throughput Typical range (in buildings - in urban environment) Notes
2 Mbit/s Highest 20 - 50 m Required for 4,000 Hz with multiple nodes
1 Mbit/s High 50 - 125 m Good balance at 1,000 - 2,000 Hz, for single-sensor mode longer range at 4,000 Hz
500 kbit/s Medium 90 - 225 m Often best for longer range at moderate rates; especially for SHM on bigger structures, verify with the nemi Link 2400 Radio Channel Calculator
125 kbit/s Low 140 - 350 m Longest range, only for low sampling rates, verify with the nemi Link 2400 Radio Channel Calculator
  • At 4,000 Hz primary rate, 2 Mbit/s (for up to 3 nodes) or 1 Mbit/s (for 1 node) is required. The 500 kbit/s mode cannot reliably sustain 4,000 Hz with some headroom for retransmissions.
  • Up to 8 sensor nodes can share one channel; at 4,000 Hz, 3 nodes is the practical maximum.
  • For latency-sensitive or control-loop applications, use single node mode to eliminate channel-sharing overhead (latency ~7–8 ms at 2 Mbit/s with one node).
  • Use channels with ≥10 spacing between independent networks (e.g. channel 0 and channel 10). Channel 0 is the default; channel 10 is slightly more exposed to potential WLAN interference.

Tilt, Roll, Pitch and Yaw / Inclination measurements

Tilt / inclination (quasi-static):

  • Use M08 variant at ±2 g range and 125 Hz sampling rate.
  • Apply a low-pass filter (2nd–4th order Butterworth, 0.5–2 Hz cutoff) to isolate slow tilt from vibration noise.
  • Compute roll and pitch with atan2:

roll  = atan2(acc_y, acc_z)
pitch = atan2(-acc_x, sqrt(acc_y² + acc_z²))
- For precise absolute tilt, use a factory-calibrated unit. Uncalibrated units show reproducibility < 100 µm/m inclination relative to a baseline; with calibration absolute measurements are more precise.

Yaw (heading): Yaw cannot be derived from acceleration alone. A full sensor-fusion algorithm combining ACC + GYR + MAG is required. The open-source xioTechnologies Fusion library (https://github.com/xioTechnologies/Fusion) is a practical solution. The nemi G+ follows a North-East-Down (NED) coordinate convention (X = North/Roll, Y = East/Pitch, Z = Down/Yaw).

Magnetometer-based yaw is sensitive to nearby ferromagnetic materials, current-carrying cables and magnetic mounts. Avoid magnetic mounting when accurate yaw is required.

Power Consumption and Battery Life

Radio mode and sampling rate are the dominant factors for battery life. IMU channels also contribute. The following table shows some values.

Current consumption of nemi G+ in different radio modes and sampling rates

Configuration Approx. current @ 3.3 V
Sleep mode < 100 µA
1,000 Hz primary @ 1 Mbit/s radio ~5.9 mA (≈ 20 mW)
1,000 Hz primary @ 500 kbit/s radio ~8.6 mA (≈ 29 mW)

Runtime estimates with the integrated battery (120 mAh):

  • Sleep only: ~ 45 days
  • 1,000 Hz continuous @ 1 MBit/s: ~18 hours

To maximize battery life:

  1. Use the lowest acceptable sampling rate.
  2. Disable unused IMU channels (GYR and MAG in particular).
  3. Prefer 2 Mbit/s radio mode where range allows (lower on-air time).
  4. Use sleep + wake scheduling for duty-cycled installations.

For the nemi G+ nano OEM variant (circuit board, external battery), the datasheet gives the following projected runtimes at 1,000 Hz, ACC + GYR + MAG active, 2 Mbit/s radio mode (average 4.66 mA at 3.3 V ≈ 15.4 mW):

Power source Projected runtime
1 × Saft LS 14250 (BAT pin) ~10 days
1 × Saft LS 33600 (BAT pin) ~147 days
2 × Saft LS 33600 in series (DCIN pin) ~281 days
4 × Saft LS 33600 in series (DCIN pin) ~535 days

See the nemi G+ nano page for details and the efficiency assumptions.

Time Synchronization

Within one nemi Link 2400 wireless network, nemi G+ sensor-node clocks are synchronized to the receiver module. The synchronization accuracy within the wireless sensor network is ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long, so the clocks are corrected less often. This is the relevant precision for aligning multiple nemi G+ nodes connected to the same receiver.

The receiver then handles its own downstream synchronization to the host system. For example, nemi EdgeBase uses NTP or GNSS; nemi Log uses the internal RTC (real time clock) or GNSS; nemi Connect follows the host computer clock. This second stage synchronization — and its use in multi-receiver setups — is documented with the respective receiver product.


Integration

nemi G+ itself communicates only via nemi Link 2400 radio to a receiver. All external integration happens at the receiver level. Choose the receiver according to the required integration path:

Receiver Best for Data access
nemi Connect PC-based live testing, ad-hoc measurements with nemi Studio or the nemi Studio Web App, CSV logging, custom USB integration with our nemi Connect Python API USB virtual COM port
nemi Log Compact local medium-term standalone logging; alternatively usable as a USB receiver for nemi Studio, like nemi Connect nemi Log .bin files with Python Decoder
nemi EdgeBase Long-term standalone field monitoring, MQTT, FTP, LTE/VPN, edge computing nemi EdgeBase .bin.bz2 Files via Ethernet, LTE, OpenVPN, FTP, decoding with Python Decoder, MQTT(s) streams

Integration Architecture

nemi G+ sensor(s)
    │  nemi Link 2400 (2.4 GHz wireless)
    ▼
Receiver module
    ├── nemi Connect → USB → PC (nemi Studio / nemi Studio Web App / Python API / custom parser)
    └── nemi Log → SD card / LTE Cat M or NB-IoT with cellular option
              ├── MQTT broker  (aggregated values) → Database → Dashboard
              ├── FTP server   (raw binary files) → Python decoder → Pandas Dataframes
    └── nemi EdgeBase → Ethernet / LTE / OpenVPN
              ├── MQTT broker  (real-time aggregated values) → Database → Dashboard
              ├── FTP server   (raw compressed binary files) → Python decoder → Pandas Dataframes

Python API (via nemi Connect)

The nemi Connect presents a virtual COM port (serial over USB). The Python API library (provided by i4M on request) decodes the provided data stream in real time and exposes sensor data as pandas DataFrame queues.

Getting started:

  1. Connect the nemi Connect to the PC via USB.
  2. Download the Python API package (ask i4M for a link).
  3. Open the example script (nemi_connect_python_api.py) as a working reference.

The package includes full protocol documentation, example scripts and all sensor channel definitions. Implementation support for custom integrations is available on a per-project basis.

Any Linux or Windows system with a USB port can host a custom integration!

MQTT Streaming (via nemi EdgeBase)

MQTT is the primary real-time integration path for dashboards, SCADA systems and cloud platforms. The EdgeBase publishes time-aggregated statistics to any MQTT broker at a configurable interval (minimum ~0.1 s = 10 Hz).

MQTT configuration (mqtt_config.yml on the EdgeBase):

mqtt_broker_address: "192.168.1.100"
mqtt_broker_port: 1883           # commonly 8883 with TLS
mqtt_broker_client_id: "edgeBase_node1"
mqtt_broker_user: "username"
mqtt_broker_password: "password"
mqtt_root_topic: "MyCompany/Site1"
mqtt_send_interval: 1.0          # 1.0 s = 1 Hz publish rate
mqtt_use_mqtts: 0                # 1 = MQTTS (TLS with client certificates)

Topic structure: <root_topic>/<sensor>/<stream>, e.g. MyCompany/Site1/nemi_G_1/STREAM_0. <sensor> is the file_identifier from the EdgeBase sensor configuration — the same name that identifies the sensor in the logged file names. Each message carries all channels of one stream:

Stream Content Channels
STREAM_0 Primary MEMS accelerometer TIMECOUNTER, VIB_X, VIB_Y, VIB_Z
STREAM_1 IMU and status TIMECOUNTER, ACC_X/Y/Z, GYR_X/Y/Z, MAG_X/Y/Z, TEMP, VOLT (battery voltage), RSSI

MQTT payload format (UTF-8 JSON, QoS 2):

{
  "timestamp": "2026-06-24T19:43:52.077665+00:00",
  "values": {
    "VIB_X": {"min_value": -0.021, "max_value": 0.019, "mean_value": -0.001},
    "VIB_Y": {"min_value": -0.017, "max_value": 0.022, "mean_value": 0.002},
    "VIB_Z": {"min_value": -1.012, "max_value": -0.988, "mean_value": -1.000}
  }
}

Within each mqtt_send_interval, the EdgeBase computes minimum, maximum and mean over all received samples; the timestamp (UTC) marks when the interval was emitted. Iterate over the keys present in the payload rather than assuming a fixed schema. See nemi EdgeBase for the full MQTT reference. MQTT is suitable for reduced/aggregated values, not for continuous high-rate waveforms. Retrieve raw sample-level data via FTP.

Minimum sampling rate for MQTT: Each nemi G+ message carries 25 samples. For 10 Hz MQTT output, a minimum primary sampling rate of 250 Hz is required (25 samples × 10 Hz); 500 Hz or higher is recommended for margin.

FTP Raw Data (via nemi EdgeBase)

Raw time-series data is stored on the internal SSD of the EdgeBase as compressed binary files (.bin.bz2). Recommended file duration is 5 - 10 minutes per file. Files are named with the recording start timestamp.

FTP access is available both locally (Ethernet) and remotely (via OpenVPN).

The i4M Python decoders decode the .bin.bz2 files of the nemi EdgeBase and the .bin files of the nemi Log into pandas DataFrames, which can be saved as CSV, Parquet etc. or processed directly in Python.

Protocol and Decoding

For custom integrations at protocol level (e.g. reading the nemi Connect USB stream directly), the basic principles are:

  • The nemi Connect appears as a virtual COM port (USB CDC). All nemione devices use the same binary data messages, which are framed with COBS encoding (a zero byte separates the messages).
  • Each nemi G+ data message contains a block of 25 samples of the primary accelerometer (three axes, 20 bit) plus one IMU and temperature sample (IMU at 1/25 of the primary rate). At 4,000 Hz, one message spans 6.25 ms.
  • Each message carries the synchronized timestamp of the last contained sample (1 µs resolution); earlier sample times are reconstructed from the sampling rate. The 32-bit time counter overflows after approx. 71.6 minutes.
  • The data message contains no range information; the receiver side must use the range last sent to the node (see M256 Variant — Range Configuration).
  • Keep sensor firmware, receiver software and decoder versions matched, and document them with each data set.

The complete USB data message protocol documentation (message structure, conversion factors) is provided to customers on request — i4M discloses the protocol to its customers.

Third-Party DAQ Integration

Gantner Instruments Q.Station: Connect via nemi Connect (USB). For use with the GI nemione plugin.

Custom gateway (Raspberry Pi or industrial PC): nemi Connect → USB → gateway → Python API → any downstream protocol (OPC-UA, MQTT, REST, etc.).

Two-receiver setups: When sensors in the same installation require different radio modes (e.g. a high-speed group at 4,000 Hz / 2 Mbit/s and a long-range group at 125 Hz / 500 kbit/s), use two separate nemi Connect receivers on the host system.


Troubleshooting

Radio and Connectivity

Symptom Likely cause Resolution
No data in nemi Studio / nemi Studio Web App; sensor LED flashes multicolor and repeats this pattern (sensor resets) Channel, radio mode or node number mismatch between sensor and receiver Reconfigure sensor via nemi Sensor Config; match channel and radio mode on both sides
Sensor flashes the green LED but receiver sees no traffic Sensor in sleep mode after restart without receiver contact Power-cycle the sensor; wake from receiver/application
Green LED on continuously in wireless mode Ring buffer 80 % full — radio link cannot keep up Improve antenna placement, reduce sampling rate, reduce node count, or switch to a faster radio mode
Intermittent missing samples at high sampling rate Channel bandwidth exceeded (e.g. 500 kbit/s cannot sustain 4,000 Hz) Switch to 2 Mbit/s, or reduce sampling rate; verify with the nemi Link 2400 Radio Channel Calculator
Reception works on the bench but fails at the installed location Metal shielding, body absorption, or antenna pointing into structure Move receiver antenna, point plastic-cover side toward receiver, test with 500 kbit/s mode
Data drops when the machine rotates into certain positions Rotating structure periodically blocks the radio path Reposition the receiver antenna so it covers the full rotation; use a slower radio mode if the data rate allows
A sensor appears under the wrong node or not at all Duplicate node number or wrong maximum-node setting Give each sensor on the same channel a unique node number and set the same node count on sensors and receiver

Data Quality

Symptom Likely cause Resolution
Progressively increasing missing-sample rate from one sensor Battery voltage falling below operating threshold Recharge the battery
Signal clips at peaks Measurement range too narrow for actual signal Increase primary MEMS range; if the signal can exceed 8 g, switch to the M40 variant, beyond 40 g to the M256 variant
Offset of several tenths of a g on M256 in ranges ≥ ±32 g Separate high-g element with larger zero offset Use Node Zero and Scaling in nemi Studio or compensate the offset in post-processing
Spectra differ from a reference sensor Bandwidth, mounting, filter chain or axis mismatch Check −3 dB bandwidth of both systems; use rigid screw mount; document axis definitions; compare only within the shared useful bandwidth
Small signals look noisy Range too wide, sampling rate higher than needed, soft mounting Select a smaller range, reduce the sampling rate (bandwidth), improve the mounting
Tilt result drifts or disagrees with an inclinometer Mounting stability, temperature effects, missing calibration, coordinate transform Use a calibrated M08 unit, rigid mounting, low sampling rate, low-pass filtering and a documented orientation transform
Yaw is unstable Magnetometer disturbed by magnets, steel or electrical currents Avoid magnetic mounting and magnetic disturbances, or do not rely on magnetometer-based heading

Data Decoding and Timing

Symptom Likely cause Resolution
Custom parser delivers implausible values COBS framing not decoded first Decode the COBS frames before interpreting the messages
Decoded acceleration scale is wrong Wrong range assumption or firmware/decoder mismatch Use the range last sent to the node and the matching decoder version
Time axis jumps in long recordings 32-bit timecounter rollover (every ~71.6 min) not handled Use the i4M decoder, which corrects the rollover, or handle it in your own pipeline
Interpolation hides real missing data Gaps resampled without marking packet loss Detect timestamp gaps first, mark missing data as NaN, then resample only valid intervals

Power and Hardware

Symptom Likely cause Resolution
USB connected but no COM port appears Charge-only USB cable Use a data-capable micro-USB cable
Sensor leaves USB configuration mode before settings are written Normal 10-second timeout Open nemi Sensor Config COM-Port connection while nemi G+ green/yellow LED state is active (within 10 seconds of nemi G+ power-on)
Sensor stops during a long run Battery runtime exceeded or unstable supply Charge fully, reduce sampling rate, use sleep scheduling, or use the 5–30 V DC wide-range input
Sensor restarts repeatedly Weak battery, unstable external supply Charge the battery, verify supply voltage and polarity, then retest with USB power

Trigger Issues (on nemi EdgeBase)

Symptom Likely cause Resolution
Trigger stops firing after extended deployment Seasonal or diurnal temperature change shifts the quasi-static acceleration baseline; threshold set without margin Set threshold with 25–50 % margin below expected event amplitude; switch trigger source from IMU to primary MEMS (trigger_stream: 0), which has lower temperature drift
Trigger fires on thermal baseline shift, not on real events Temperature sensitivity of IMU accelerometer too high for threshold Reduce threshold margin cautiously or use primary MEMS as trigger stream

Product Changes

Hardware Variants

Variant Primary MEMS ranges Order code suffix
nemi G+ M08 ±8 / 4 / 2 g M08
nemi G+ M40 ±40 / 20 / 10 g M40
nemi G+ M256 ±256 / 128 / 64 / 32 / 16 / 8 / 4 / 2 g M256

Ordering designation: nemi G+ Mxx (xx = 08, 40 or 256). The standard housing comes with a stainless steel base (approx. 50 g); an aluminum base (approx. 30 g) is available.

Standard housing protection class is IP41. Weather-resistant IP67 protection is available on request and must be specified at order time.

nemi G+ ultra — Higher-Bandwidth Variant

The nemi G+ ultra is a distinct product variant for applications requiring bandwidth above 800 Hz (e.g. machinery diagnostics above 1 kHz). Key differences vs. the standard nemi G+:

Parameter nemi G+ nemi G+ ultra
Max. sampling rate 4,000 Hz 26,600 Hz
−3 dB bandwidth at max rate 800 Hz > 6 kHz
Typical use Structural monitoring, general vibration Machinery diagnostics, high-bandwidth applications

For applications with required bandwidth below 800 Hz, the standard nemi G+ is preferred (better noise and resolution).

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio 1.1 Beta 2 (as of November 2026)
nemi Studio Web App 2026.11.04.3 (as of November 2026)
wirelessSensorPlot 7.4 — legacy, no longer maintained; replaced by nemi Studio and nemi Studio Web App
nemi Link 2400 Radio Channel Calculator Online tool, always current (replaces the Excel configuration tool)

FAQ

Applications

Can nemi G+ measure vibration on rotating machinery? Yes — this is one of its primary design targets. The sensor is self-contained and wireless, so it mounts directly on rotating shafts, pitch bearings and gearboxes without slip rings. For high-rpm applications where centrifugal acceleration can be large, verify that peak centrifugal plus vibratory acceleration does not exceed the sensor range, and use the M40 variant if total acceleration can exceed 8 g.

Can nemi G+ be used on roller coasters or amusement rides? Yes. The sensor measures translational and rotational movements on highly dynamic vehicles. Use the M40 variant if g-peaks exceed 8 g, or the M256 variant beyond 40 g. Data is transmitted live during radio coverage; when the vehicle is temporarily out of range (e.g. in a tunnel), data is buffered in the internal ring buffer and retransmitted automatically when coverage is restored.

Can nemi G+ be used as an inclinometer? Yes, for many quasi-static tilt and inclination-change applications. Use the M08 variant at ±2 g and 125 Hz; apply a low-pass filter; mount the sensor rigidly. Field tests show repeatability better than 100 µm/m inclination on uncalibrated units, and resolution approaching 20 µm/m inclination with careful filtering and calibration. The primary limitation for long-term deployments is MEMS temperature drift.

Can nemi G+ replace a piezoelectric accelerometer? Yes, but not universally. nemi G+ measures down to DC (static gravity), which IEPE/piezo sensors cannot. It is easier to deploy wirelessly and on rotating parts. High-end piezoelectric sensors have lower noise floors and can reach higher bandwidths. For applications above 1 kHz of bandwidth use nemi G+ ultra and where absolute lowest noise and bandwidths above 6 kHz are required, piezo sensors offer benefits.

Can nemi G+ be used for structural health monitoring on bridges? Yes, for structures with dominant frequencies below ~800 Hz — which covers most bridges, wind turbines and civil engineering assets. Its 20-bit primary accelerometer at ±2 g provides approximately 3.9 µg/LSB sensitivity, very low noise figures, and the measurement extends down to DC, enabling simultaneous tilt and dynamic response monitoring.

Can nemi G+ measure displacement? Not directly. Displacement must be derived by double-integrating the acceleration signal, which amplifies any sensor offset (velocity error grows linearly; displacement error grows quadratically). A high-pass Butterworth filter (4th order, 0.5 Hz) before integration reduces offset-driven drift. Use a factory-calibrated unit and mechanically constrain non-measured axes. This approach works for short events with known signal characteristics; for continuous displacement monitoring, a direct displacement sensor is needed.

Can nemi G+ operate in wet or harsh environments? The standard housing is rated IP41. An IP67 weather-resistant version is available on request. For severe water-splash or immersion risk, confirm the enclosure IP rating before deployment. The nemi G+ nano PCB can be integrated into a custom sealed enclosure with an external antenna.

Connectable Sensors

What sensors are built into nemi G+? Primary triaxial MEMS accelerometer (20-bit for M08 and M40, 16-bit for M256), secondary 9-DoF IMU (3-axis ACC, GYR, MAG, 16-bit) and internal temperature sensor. All sensors are integrated; no external sensors can be connected.

When should I use the primary MEMS vs. the IMU accelerometer? Use the primary MEMS for all precision vibration and tilt measurements — it has 20-bit resolution and lower noise. The IMU accelerometer (16-bit) is useful for orientation-change detection and sensor fusion for roll/pitch/yaw.

Does the magnetometer work with magnetic mounting? No. Magnetic mounting disturbs the integrated magnetometer. If heading or yaw data is needed, use a non-magnetic mounting method (screw, adhesive or mechanical plate).

Power Supply

How long does the internal battery last? More than 10 hours at 4,000 Hz with all three primary axes active. At lower sampling rates, runtime can extend to several days. Calculate runtime in Wh (not only mAh) for multi-cell external battery setups.

How is the sensor charged? Via micro-USB; a full charge takes approximately 3 hours. When the wide-range voltage input is connected, the internal battery also charges.

Can nemi G+ run continuously without a battery? Yes — connect the 5–30 V DC wide-range voltage input for continuous operation in permanent installations.

What is the power consumption in sleep mode? Less than 100 µA at 3.3 V. At 12 V via the wide-range input, approximately 1 mA in sleep (voltage converter overhead).

Radio and Range

What is the maximum radio range? Radio range depends on mode, antenna placement and obstructions. Typical values: 20–50 m at 2 Mbit/s, 50–125 m at 1 Mbit/s, 90–225 m at 500 kbit/s and up to 350 m at 125 kbit/s (sampling rates up to 250 Hz). Under favorable conditions (elevated antennas, clear line-of-sight), several hundred meters are possible, but must always be validated on-site.

How many sensors can share one nemi Connect / receiver? Up to 8 per radio channel. At 4,000 Hz primary sampling, the practical limit is 3 sensors per channel. Use the nemi Link 2400 Radio Channel Calculator to confirm any configuration before deployment.

What does the green LED in wireless mode mean? The internal ring buffer is 80 % full because radio transmission cannot keep up with data generation. Improve the radio link (antenna position, shorter range, fewer nodes) or reduce the sampling rate. If unaddressed, data loss will follow.

Which radio mode should I start with? Use 2 Mbit/s for the first test at the highest required sampling rate. If range is insufficient at 2 Mbit/s, switch to 1 Mbit/s, 500 kbit/s and verify with the bandwidth tool that the desired sampling rate still fits.

Why does reception fail inside a metal housing or vehicle? 2.4 GHz radio transmissions are strongly attenuated by metal. Place the receiver antenna outside the metal structure, or use the nemi G+ nano with an external antenna pigtail routed to the outside.

Integration

Can I get live data into my own software? Yes. With nemi Connect, data is available on a USB virtual COM port. Use the provided nemi Connect Python API package or implement the binary protocol directly. Full protocol documentation is available from i4M.

Is MQTT on the nemi EdgeBase suitable for raw vibration data? No — MQTT is designed for aggregated/reduced values (latest, mean, min, max) at rates up to ~10 Hz. For raw high-rate waveforms, download binary files from nemi EdgeBase via FTP and decode them locally with our Python decoder.

Are multiple sensors synchronized? Yes. Within one nemi Link 2400 wireless network, sensor clocks are synchronized to the receiver with ±10 µs accuracy with a stable radio connection.

How are multiple receivers synchronized? That is handled by the receiver stage, not by the nemi G+ itself: nemi Connect / nemi Log in USB receiver mode via the host computer clock (synchronize it with NTP), nemi Log via RTC or GNSS, nemi EdgeBase via NTP or GNSS. See the respective receiver page.

What file formats are used? nemi Studio and the nemi Studio Web App write semicolon-separated CSV files (period as decimal separator) that can be processed in Python, MATLAB, DIAdem, PlotJuggler or similar tools. nemi EdgeBase stores raw data as compressed binary files (.bin.bz2), nemi Log as .bin files; both are decoded with the i4M Python decoders into pandas DataFrames, which can be saved as CSV, Parquet etc. or processed directly in Python.

Can I integrate nemi G+ with a Gantner Instruments Q.Station? The integration path is: nemi G+ → nemi Connect (USB) → Q.Station USB input → GI nemione Plugin. Several nemi Connect units per Q.Station are possible.

Configuration and Software

Which tool configures the radio settings? nemi Sensor Config (v2.1 or later) via USB to micro-USB connection. Radio mode, channel, node number and maximum-node count are configured here.

Which tool is used for live display and CSV logging? nemi Studio (Windows, v1.1 or later) or the nemi Studio Web App (browser) with a nemi Connect, a nemi Log in USB receiver mode or a nemi EdgeBase receiver. wirelessSensorPlot is no longer maintained.

How do I verify that my configuration fits within radio bandwidth? Use the nemi Link 2400 Radio Channel Calculator. Run this check before every deployment; do not rely on intuition for bandwidth estimates.

Do I need factory calibration? For most dynamic vibration measurements, uncalibrated accuracy (< 8 % of range) is sufficient. For precise absolute acceleration or tilt measurements, order factory calibration with calibration certificate; this reduces the static inaccuracy to < 0.1 % (M08) or < 1.0 % (M40, M256) of range.

Which hardware variant should I order — M08, M40 or M256? Choose M08 for low-amplitude acceleration, vibration, tilt and best resolution at ±2 g. Choose M40 when shocks, impacts or centrifugal acceleration in rotating applications can exceed 8 g. Choose M256 when accelerations can exceed 40 g.