nemi Struct is the nemione solution for wireless long-term structural health monitoring (SHM) with live data. At its core, nemi Struct is a weatherproof, robust housing made of aluminum and polycarbonate (IP66, 216 × 120 × 55 mm) with a self-sufficient long-term power supply that integrates a proven nemione sensor node. Two main variants are available:

  • nemi Struct G+ with an integrated nemi G+ nano for measuring vibrations and inclinations (triaxial MEMS accelerometer, 9-DoF IMU, temperature sensor).
  • nemi Struct DAQ with an integrated nemi DAQ nano for acquiring data from connected sensors such as strain gauges, potentiometric displacement sensors, temperature sensors or sensors with 0–10 V output.

Both variants can be combined either with a battery pack (two lithium D cells) for more than one year of continuous live operation, or with a solar power supply (external 10 Wp solar panel and internal buffer storage) for maintenance-free, permanent live streaming.

Data is transmitted via i4M's nemi Link 2400 radio technology (2.4 GHz) over distances of up to 350 m in real-world environments. nemi Struct is a sensor node, not a receiver: it requires a compatible nemi Link 2400 receiver — nemi Connect (USB receiver for PC or Gantner Q.Station), nemi Log (compact SD logger with cellular option) or nemi EdgeBase (autonomous field gateway with 4G, edge computing and local SSD storage). All receivers use a star topology with one receiver per radio channel and up to eight sensor nodes per channel. The receiver handles data access, storage, downstream integration and time synchronization to host or external time sources.

Data can be transmitted as live raw samples or as pre-evaluated "smart data" computed by the onboard 64 MHz 32-bit MCU. Edge computing can be realized upon request in bilateral development projects.


Typical Applications

  • Bridges and civil engineering structures — long-term vibration, inclination and settlement monitoring (nemi Struct G+), or crack and deflection monitoring with displacement sensors and strain gauges (nemi Struct DAQ).
  • Wind turbine structures — long-term monitoring of large structures such as towers and rotor blades.
  • Ships and amusement rides — dynamic monitoring of moving structures such as roller coasters. Data is buffered when the node is temporarily out of radio range; variants with internal flash memory bridge radio interruptions of up to several minutes.
  • Long-term outdoor monitoring campaigns — battery runtime of more than one year or unlimited runtime with the solar option avoids frequent site visits; no cable routing and no local power supply required.
  • Industrial and process monitoring with external sensors — nemi Struct DAQ with strain gauges, potentiometric displacement sensors, Pt100 / Pt1000, thermocouples, thermistors, 0–10 V sensors and digital (switching) sensors.
nemi Struct G+ nemi Struct DAQ
Integrated sensor node nemi G+ nano nemi DAQ nano
Main measured variables Vibrations (accelerations) and inclinations in 3 axes Signals of connected sensors: strains, displacements, forces, temperatures, 0–10 V
Main sensor / inputs Triaxial MEMS accelerometer (M08, M40 or M256 variant) 2 or 3 analog inputs (24 bit) and 2 digital inputs
Max. live sampling rate 4,000 Hz (main sensor) 6,400 Hz (1 channel); 1,944 Hz (2 channels); 1,296 Hz (3 channels)
Additionally integrated 9-DoF IMU, temperature sensor 9-DoF IMU, temperature sensor
Runtime with battery pack 1.0 years @ 125 Hz continuously 1.2 years @ 100 Hz continuously (2 × strain gauge)
Typical applications Vibration monitoring, modal analysis, inclination and settlement monitoring Deflection and load measurement with strain gauges, crack monitoring with displacement sensors
nemi Struct on a bridge nemi Struct mounted below a structure Crack monitoring with a displacement sensor
nemi Struct on a bridge nemi Struct mounted below a structure Crack monitoring with displacement sensor

Technical Specifications

General (all variants)

Parameter Value Unit
Dimensions (without antenna and cable glands) 216 × 120 × 55 mm
Housing material Aluminum and polycarbonate —
Housing protection class IP66 —
Operating temperature −20 to 60 °C
Onboard MCU, usable for edge computing 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, hardware crypto —
Radio technology nemi Link 2400, 2.4 GHz frequency band —
Radio range up to 350 (nemi Link 2400 XR @ 125 kbit/s) m
Option Internal flash memory to bridge longer radio interruptions of up to several minutes —

Dimensions of nemi Struct

Outer dimensions of nemi Struct in mm (housing height 55 mm). Mounting holes Ø 4.3 mm.

Power Supply

Parameter Value Unit
Battery pack option 2 × lithium thionyl chloride D cell (Saft LS 33600), 3.6 V each —
Runtime with battery pack (continuous live operation) 1.0–1.5 (depending on variant and sampling rate, see runtime table) years
Solar option: buffer storage Industrial lithium-ion power bank, 6,700 mAh —
Solar option: voltage range of buffer storage approx. 3.3 (empty) to 4.1 (full) V
Solar option: solar panel 10 Wp; 223 × 148 × 3.6 mm —
Runtime with solar option Unlimited with suitable panel orientation —

Variant nemi Struct G+ — Main Sensor (MEMS Accelerometer)

Parameter Value Unit
Sensor type High-resolution triaxial capacitive MEMS accelerometer —
Selectable sampling rates 4,000 / 2,000 / 1,000 / 500 / 250 / 125 Hz
Realizable −3 dB bandwidths 800 / 500 / 250 / 125 / 62.5 / 31.25 Hz
Sampling-rate stability (full temperature range) ± 50 ppm
Non-linearity (related to measuring range) 0.1 %
Cross-axis sensitivity 1.0 %
Static 3D inaccuracy without calibration < 8 % of range
Static 3D inaccuracy with factory calibration (on request) < 0.1 (M08) / < 1.0 (M40) / < 1.0 (M256) % of range
Inclination resolution 10 µm/m
M08 variant — selectable ranges / resolution / resonance frequency ± 8 / 4 / 2 g · 20 bit · 2,400 Hz —
M40 variant — selectable ranges / resolution / resonance frequency ± 40 / 20 / 10 g · 20 bit · 5,500 Hz —
M256 variant — selectable ranges / resolution / resonance frequency ± 256 / 128 / 64 / 32 / 16 / 8 / 4 / 2 g · 16 bit · 2,400 Hz —

Frequency Responses

Frequency response ± 8 g variant Frequency response ± 40 g variant
Frequency response ± 8 g variant Frequency response ± 40 g variant

Variant nemi Struct G+ — Additional 9-DoF IMU and Temperature Sensor

Parameter Value Unit
Sampling rate IMU and temperature sensor 1/25 of the main sensor rate (e.g. 160 Hz at 4,000 Hz) Hz
IMU accelerometer ranges ± 16 / 8 / 4 / 2 g
IMU gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
IMU magnetometer ranges ± 16 / 12 / 8 / 4 Gauss
IMU signal resolution 16 bit
Temperature sensor: measuring range / resolution −20 to 60 / 0.1 °C

Variant nemi Struct DAQ — External Analog Sensors

Parameter Value Unit
Connectable analog sensors Reference-voltage sensors (Wheatstone / strain gauge full bridges, potentiometer sensors, thermocouples e.g. type K, thermistors); reference-current sensors (Pt100 / Pt1000); sensors with 0–10 V output —
Number of analog channels max. 2; max. 3 with nemi Struct DAQ 3 Channel —
Max. sampling rates 6,400 (1 channel); 1,944 (2 channels); 1,296 (3 channels) Hz
Sampling-rate stability (full temperature range) ± 50 ppm
Selectable signal gains 128 / 64 / 32 / 16 / 8 / 4 / 1 —
Constant-current feed current 500 µA
Wheatstone bridge supply voltage 2.5 V
Signal resolution 24 bit
Analog measurement error ≪ 0.1 (with automatic self-calibration) %

Variant nemi Struct DAQ — External Digital Sensors

Parameter Value Unit
Examples Switching displacement, distance, level or rotation-angle sensors; TTL / NPN sensors —
Number of digital channels max. 2 —
Signal level 3.3–24 V

Variant nemi Struct DAQ — Additional 9-DoF IMU and Temperature Sensor

Parameter Value Unit
IMU sampling rates 3,332 / 1,666 / 833 / 416 / 208 / 104 / 52 Hz
IMU accelerometer ranges ± 16 / 8 / 4 / 2 g
IMU gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
IMU magnetometer ranges ± 16 / 12 / 8 / 4 Gauss
IMU signal resolution 16 bit
Temperature sensor measuring range −20 to 60 °C

Detailed information on sampling rates, signal gains and measuring ranges of the DAQ variant can be found on the nemi DAQ nano page.

Runtimes with Battery Pack

Integrated sensor node Measured variables Sampling rate Runtime
nemi G+ nano 3-axis vibration and inclination 125 Hz, continuous, live 1.0 years
nemi DAQ nano 2 × strain gauges (1,000 Ω), e.g. for deflection measurement 100 Hz, continuous, live 1.2 years
nemi DAQ nano 2 × displacement sensors (potentiometric, 1,000 Ω), e.g. for dynamic crack monitoring 50 Hz, continuous, live 1.5 years
Parameter Value
Frequency band 2.4 GHz
Topology Star (one receiver per channel)
Max. sensor nodes per channel 8
Time synchronization within the network ±10 µs with a stable radio connection
Compatible receivers nemi Connect, nemi Log, nemi EdgeBase

First Commissioning

Required Hardware and Software

Item Purpose
nemi Struct (G+ or DAQ variant) Sensor node
nemi Connect / nemi EdgeBase / nemi Log Receiver
Micro-USB cable (data-capable, not charge-only) USB configuration of the integrated sensor node
nemi Sensor Config v2.1 or later Radio configuration via USB
nemi Studio v1.1 or later, or nemi Studio Web App Live display, sensor settings and CSV recording

nemi Sensor Config and nemi Studio are provided to customers via download links (the software is not publicly available). The nemi Studio Web App runs in Chrome or Edge at https://nemi.one/studio/.

Step 1 — Plan the Radio Network

Before going to site, decide:

  1. Radio mode — use the fastest radio mode that still reaches the required distance; this minimizes on-air time and energy consumption. Example: 6 nodes at ≤ 30 m with 250 Hz each → 1 Mbit/s.
  2. Radio channel — use channel 0 (default) for a single system. For several systems within radio range, use well separated channels such as 0, 25, 50 and 75; keep at least 10 channels spacing between independent networks. Channel 10 also works, but is slightly more exposed to potential WLAN interference than channel 0.
  3. Node numbers — each node on the same channel needs a unique node number. A typical 6-node bridge setup:
Radio mode:  1 Mbit/s
Channel:     0
Node 1–2:    nemi Struct G+
Node 3–6:    nemi Struct DAQ
  1. Channel utilization — verify with the nemi Link 2400 Radio Channel Calculator (online tool) that the sum of all sampling rates fits within the bandwidth of the chosen radio mode. Do not rely on intuition for bandwidth estimates.

Step 2 — Configure the Integrated Sensor Node via USB

Persistent radio parameters (channel, radio mode, node number, maximum nodes) are written with nemi Sensor Config via the micro-USB connector of the integrated sensor node inside the housing. The procedure is the same as for the nemi G+ nano and nemi DAQ nano:

  1. Open the housing and connect the micro-USB cable from the integrated node to the PC. Use a data-capable cable.
  2. Launch nemi Sensor Config and power on the node. Connect to the detected COM port within approx. 10 seconds; otherwise the node starts in radio transmission mode.
  3. Enter channel, radio mode, node number and node count and click Set nemi Link Parameters.
  4. Close the COM port connection in nemi Sensor Config before unplugging the USB cable.

If nemi Sensor Config does not detect the node: disconnect all other nemi devices (including nemi Connect), close the software, reopen it and connect only the target node.

Step 3 — Connect Sensors (DAQ Variant Only)

Connect external sensors through the cable glands to the analog and digital inputs of the integrated nemi DAQ nano (see Mounting & Connections). The configuration of the analog inputs (reference voltage, reference current or 0–10 V) is defined before delivery — specify the sensor types when ordering.

Step 4 — Power On

Insert / connect the battery pack or connect the solar panel to the housing and switch the node on. With the solar option, make sure the panel is oriented towards the open sky (see Power Supply below).

Step 5 — Set Up the Receiver and Verify Data

With nemi Connect (or nemi Log in USB receiver mode):

  1. Plug the nemi Connect into the PC and launch nemi Studio or open the nemi Studio Web App in Chrome or Edge.
  2. Connect the COM port, set the same radio mode, node count and channel as on the sensor nodes, select the module type of each node (nemi G+ nano for nemi Struct G+, nemi DAQ nano for nemi Struct DAQ) and click Start Receiver.
  3. Within a few seconds live data should appear. Check signal strength, latency and the node status display for lost samples.
  4. Set sampling rate, ranges / gains and IMU ranges wirelessly in the software and record a short CSV file before leaving the site.

With nemi EdgeBase: configure the radio and node settings in the EdgeBase YAML files. A nemi Struct is configured like its integrated node: nemi Struct G+ as nemi G+ (sensor_type: vibration), nemi Struct DAQ as nemi DAQ (sensor_type: telemetry). During commissioning, set logging_mode: 6 in sensor_config.yml to view the live data in nemi Studio or nemi Studio Web App over the network.

With nemi Log as standalone logger: configure the radio settings via the nemi Log configuration CSV files (config.csv); a nemi Struct is entered like its integrated node (nemi G+ or nemi DAQ). The node pairs automatically when channel and radio mode match.

First Data Transmission — Checklist

  1. Receiver is powered and set to the same channel, radio mode and node count as all nodes.
  2. Each node has a unique node number on the shared channel.
  3. Live data, signal strength and latency are plausible in nemi Studio / nemi Studio Web App.
  4. Test at the intended installation location with the antennas in their final position.
  5. Record and inspect a short test file before leaving the installation site.

LED Status

The integrated sensor node signals its operating state with LEDs. The codes are identical to those of the integrated node — see nemi G+ nano or nemi DAQ nano.

Range Considerations

Radio mode Typical range (in buildings – in urban environment)
2 Mbit/s 20–50 m
1 Mbit/s 50–125 m
500 kbit/s 90–225 m
125 kbit/s (XR) 140–350 m

Range is strongly affected by antenna orientation, metal and concrete shielding and obstructions. Under favorable line-of-sight conditions up to 350 m are possible at 125 kbit/s, but the reliable range must always be validated on site with the planned sampling rate and node count.


Mounting & Connections

Mechanical Mounting

nemi Struct is mounted via the four Ø 4.3 mm holes in the housing flanges (hole spacing 65 mm, see dimension drawing). Mounting material (screws, adapter plates) is not included; it is only supplied as an option if ordered. Use an application-specific adapter plate where needed, e.g. on curved surfaces. For vibration and inclination measurements (nemi Struct G+), mount the housing rigidly so that it cannot move relative to the structure — flexible brackets or loose mounts alter the measured dynamics. Magnetic mounting can be used for temporary installations on steel structures if it is validated for the expected loads.

Axis orientation: the sensor axes are printed on the housing label. Document and photograph the mounting orientation during installation.

Antenna

The supplied antennas have a donut-shaped radiation pattern: the signal is strongest perpendicular to the antenna axis and minimal along it.

  • Orient all node and receiver antennas in the same plane (typically all vertical).
  • Do not point antennas tip-to-tip at each other.
  • On ships and large steel structures, maintain at least partial line of sight between node and receiver antennas.
  • Reinforced concrete and steel act as shields: a receiver inside a box girder communicates well with nodes inside the girder, but not with nodes outside. Use separate radio networks (one receiver each) in such cases.

External Sensor Connections (DAQ Variant)

Sensors are connected through the cable glands to the inputs of the integrated nemi DAQ nano. The pin assignment is documented on the nemi DAQ nano page.

Sensor type Connection
Wheatstone bridge / strain gauge full bridge GND, CH+, CH−, V_ref (2.5 V bridge supply)
Potentiometric displacement sensor GND, CH+, CH−, V_ref
0–10 V analog output CH+ and GND (0–10 V input configuration)
Pt100 / Pt1000 Constant-current configuration (500 µA)
Digital / switching sensors, TTL / NPN (3.3–24 V) Digital inputs DIN 1 / DIN 2

For half- or quarter-bridge strain gauges, add completion resistors externally. For 4–20 mA current-loop sensors, use a precision shunt resistor to convert the current into a voltage within the input range.

Power Supply

nemi Struct offers two long-term power supply options, both available for the G+ and the DAQ variant:

Battery pack Solar power supply
Energy storage 2 × lithium thionyl chloride D cell (e.g. Saft LS 33600, 3.6 V) Industrial lithium-ion power bank, 6,700 mAh
Energy source Primary cells (not rechargeable) External solar panel 10 Wp, 223 × 148 mm
Runtime 1.0–1.5 years in continuous live operation (see runtime table) Permanent with suitable panel orientation, also in Central Europe
Suitable for Shady measuring points and indoor use; precisely predictable runtime Energy-autonomous outdoor monitoring without maintenance visits

Battery pack

nemi Struct with battery pack Opened housing with two lithium D cells
nemi Struct with battery pack Opened housing with two lithium D cells

The battery pack consists of non-rechargeable primary cells. Never charge them and never connect them through a charging path of the sensor node.

Solar power supply

nemi Struct with solar panel

The external solar panel charges an industrial lithium-ion power bank inside the housing, which serves as buffer storage for night-time and periods of bad weather. Orient the panel towards the open sky and avoid permanent shading.

In a long-term test, a nemi Struct with solar panel was mounted on an east-facing window sill of a house in western Germany (51° N). The panel was aligned vertically towards the sky, and the house shaded approx. 50 % of the sky. The nemi Struct with nemi DAQ nano was operated with one active analog channel at 100 Hz and the IMU (9 DoF) at 104 Hz. The system was started in the middle of winter with a largely discharged buffer and ran without interruption from January 2025 to February 2026, including the following winter.

Buffer storage voltage in the long-term test with solar power supply

Buffer storage voltage in the long-term test (empty ≈ 3.3 V, full ≈ 4.1 V).

Dimensions of the solar panel

Dimensions of the solar panel in mm.


Detailed Configuration

Configuration is split into two layers:

  • Persistent radio settings — written via nemi Sensor Config over USB (channel, radio mode, node number, max. nodes).
  • Runtime measurement settings — set wirelessly via nemi Studio, nemi Studio Web App, nemi EdgeBase YAML files or nemi Log configuration CSVs (sampling rate, ranges, gains, IMU settings, sleep / intermittent mode).

The analog input configuration of the DAQ variant (reference voltage, reference current, 0–10 V) is hardware-defined before delivery.

Receiver configuration files: In nemi EdgeBase YAML files and nemi Log configuration CSVs, a nemi Struct is configured exactly like the sensor node integrated in it — nemi Struct G+ like a nemi G+ (incl. M08 / M40 / M256 range codes), nemi Struct DAQ like a nemi DAQ. In nemi Studio / nemi Studio Web App, select the module type of the integrated node (nemi G+ nano or nemi DAQ nano).

Configuration Tools Reference

Tool Connection Configures
nemi Sensor Config v2.1+ USB (micro-USB of the integrated node) Radio channel, radio mode, node number, max. nodes per channel; firmware update
nemi Studio / nemi Studio Web App via nemi Connect, nemi Log (USB receiver mode, nemi Studio) or nemi EdgeBase Sampling rate, measurement ranges, gains, IMU ranges, continuous / intermittent / sleep mode
nemi Link 2400 Radio Channel Calculator Online tool (replaces the former Excel configuration tool) Validates that sampling rates fit within the channel bandwidth for the given radio mode and node count
nemi EdgeBase YAML config files VPN / FTP Radio settings, node settings, logging, MQTT, trigger and schedules
nemi Log CSV config files SD card / FTP Radio settings, node settings, logging intervals, schedules

Sampling Rate

Use the lowest sampling rate that captures the required frequency content with margin. For steel bridges with relevant frequencies up to 50–80 Hz, 250–500 Hz is recommended. For concrete or cable-stayed bridges with lower dominant frequencies, 125–250 Hz is often sufficient and extends battery life. Lower rates reduce current consumption and leave more headroom for retransmissions on the radio channel.

Measurement Range (G+ Variant)

Always select the smallest range that avoids clipping:

Application Recommended range
Bridge vibration / SHM ± 2 g or ± 4 g (M08)
Tilt / inclination ± 2 g (M08; maximizes resolution)
General vibration ± 8 g (M08)
Shock, impact, transport monitoring M40 (± 10 / 20 / 40 g) or M256 (up to ± 256 g)

The M256 variant offers ranges up to ± 256 g at 16-bit resolution; for low-amplitude vibration and inclination the 20-bit M08 variant is preferred. For precise absolute inclination, order factory calibration (< 0.1 % of range for M08).

Signal Gain (DAQ Variant)

Signal gain (1×, 4×, 8×, 16×, 32×, 64×, 128×) is set per channel in nemi Studio / nemi Studio Web App. Set the gain so that the expected maximum signal occupies approx. 70–80 % of the input range. For a 1,000 Ω strain gauge full bridge with typical strain levels, gain 128× is common. Document bridge resistance, excitation, wiring, gain and engineering-unit conversion together.

Radio Mode and Channel Utilization

Rule: choose the fastest radio mode that still reaches the required range. Check the utilization of the channel with the nemi Link 2400 Radio Channel Calculator and keep it below 70 % (rated good) to leave headroom for retransmissions; 70–90 % only works with moderate to good signal strength, above 90 % the setup is unstable. Up to 8 nodes can share one channel; for more nodes, use additional receivers on separate channels. Details: nemi Link 2400.

Time Synchronization

Within one nemi Link 2400 network, the clocks of all nemi Struct nodes are synchronized to the receiver with an accuracy of ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long. For multi-node alignment in post-processing, use the time counter column rather than the ASCII timestamps; nemi Studio can additionally resample all nodes onto a common time grid (Resample Data).

The receiver handles the downstream synchronization to the host system (nemi Connect: PC clock; nemi Log: RTC or GNSS; nemi EdgeBase: NTP or GNSS). This is documented with the respective receiver.


Integration

nemi Struct communicates only via nemi Link 2400 with a receiver. All external integration happens at the receiver level:

Receiver Best for Data access
nemi Connect Commissioning, short-term campaigns, PC-based live measurement with nemi Studio / nemi Studio Web App, custom USB integration with the nemi Connect Python API, Gantner Q.Station USB virtual COM port
nemi Log Compact local medium-term standalone logging, optionally with cellular upload; alternatively USB receiver for nemi Studio, like nemi Connect nemi Log .bin files with Python decoder
nemi EdgeBase Long-term unattended field monitoring with SSD logging, MQTT, FTP, LTE / VPN, GNSS, edge computing .bin.bz2 files via FTP, Python decoder, MQTT(S) streams

Integration Architecture

nemi Struct G+ / DAQ nodes
    │  nemi Link 2400 (2.4 GHz wireless)
    ▼
Receiver module
    ├── nemi Connect → USB → PC (nemi Studio / Python API / Gantner Q.Station)
    ├── nemi Log → SD card / cellular option
    └── nemi EdgeBase → Ethernet / LTE / OpenVPN
              ├── MQTT broker  (aggregated values: min, max, mean) → Database → Dashboard
              └── FTP server   (raw compressed binary files) → Python decoder → pandas DataFrames

Long-term Monitoring with nemi EdgeBase

For unattended long-term SHM, nemi EdgeBase is the typical receiver: raw data is logged on the internal SSD as compressed binary files (.bin.bz2), reduced values are published via MQTT / MQTTS to any broker, and raw files are retrieved via FTP (locally or via OpenVPN). The i4M Python decoders decode the .bin.bz2 files into pandas DataFrames, which can be saved as CSV, Parquet etc. or processed directly in Python. MQTT is not intended for full-rate waveforms. A nemi Struct sends via MQTT exactly like its integrated sensor node (nemi G+ or nemi DAQ nano: same streams, channels and trigger indices); <sensor> in the topic is its file_identifier, which also identifies it in the logged file names. Configuration details: nemi EdgeBase.

Battery voltage and internal temperature of each node are transmitted as telemetry channels and can be monitored remotely, e.g. on a dashboard, to detect abnormal battery drain without a site visit.

Gantner Instruments Q.Station

nemi Struct → nemi Link 2400 → nemi Connect (USB) → Q.Station with the GI nemione plugin. The plugin resamples the per-node timestamps onto common timestamps using cubic spline interpolation, which introduces negligible error for SHM applications. For workflows with strictly raw timestamps, use nemi Studio or the Python decoder.

Custom Integration

i4M provides the nemi Connect Python API on request, enabling custom receivers on any Linux or Windows system (e.g. Raspberry Pi, industrial PC). The complete USB data message protocol documentation is provided to customers on request — i4M discloses the protocol to its customers.


Troubleshooting

Radio and Connectivity

Symptom Likely cause Resolution
No data in nemi Studio / nemi Studio Web App Channel, radio mode or node count mismatch between node and receiver Reconfigure the node via nemi Sensor Config; match channel, radio mode and node count on both sides
Frequent data gaps, node status yellow / red Radio mode too fast for the distance, or channel utilization too high Move to a slower radio mode (if the total sampling rate allows), reduce sampling rate or node count; verify with the nemi Link 2400 Radio Channel Calculator
Poor range despite short distance Antenna orientation mismatch Align all antennas in the same plane (typically vertical); avoid tip-to-tip orientation
Link fails inside concrete or steel structures Shielding (Faraday cage effect) Keep receiver and nodes on the same side of the shield, or set up separate networks
Several nearby systems disturb each other Overlapping or close radio channels Use well separated channels, e.g. 0, 25, 50, 75

USB and Configuration Software

Symptom Likely cause Resolution
nemi Sensor Config does not detect the node Several nemi USB devices connected or stale COM port Disconnect all nemi devices, close nemi Sensor Config, reopen it and connect only the target node
COM port remains locked USB removed without closing the connection in the software Restart nemi Sensor Config; close the connection before unplugging in future
USB connected but no COM port appears Charge-only USB cable Use a data-capable micro-USB cable

Power and Hardware

Symptom Likely cause Resolution
One node drains its battery faster and shows a higher internal temperature than comparable nodes Increased current draw: water ingress through damaged seals or cable glands, damaged external sensor wiring (DAQ), or an electronic fault Inspect seals, cable glands and sensor wiring; disconnect external sensors to isolate the fault; return the unit to i4M if necessary
Shorter-than-expected battery runtime Higher sampling rate / slower radio mode than planned Recalculate the expected runtime; reduce sampling rate; update the node firmware
Node disappears and briefly reappears Battery voltage near the operating limit Replace the battery pack and check for the cause of the drain
Solar system does not recover buffer voltage Panel orientation, shading, soiling or damaged cable Improve sky exposure, check cable and connector; reduce sampling rate if necessary
Cold-weather runtime lower than expected Battery voltage sag at low temperatures Use the specified battery pack for outdoor winter operation; avoid marginal single-cell designs

Conservative runtime estimate: Runtime (h) ≈ 0.9 × battery capacity (mAh) / current consumption (mA).

Data Quality

Symptom Likely cause Resolution
Multi-node plots appear slightly shifted Per-node timestamps not aligned Align on the time counter column or use the Resample Data function of nemi Studio
DAQ channel stuck at min / max or zero Open circuit, short circuit, wrong gain or wrong wiring Check wiring, sensor resistance, bridge completion and gain
Signal clips at peaks (G+) Measurement range too small Increase range; use M40 or M256 variant for shocks
Dashboard stops but raw files are still logged (nemi EdgeBase) MQTT broker unreachable, wrong credentials or certificates, firewall Test the actual broker port; VPN reachability alone does not prove MQTT reachability

Product Changes

Ordering Options

Product Description
nemi Struct G+ / Tilt Wireless acceleration and inclination measurement system with additional 9-DoF IMU and temperature sensor and integrated battery pack. Measuring ranges ± 2 / 4 / 8 g or ± 10 / 20 / 40 g (20 bit, very low noise) or ± 2 … 256 g (16 bit); max. 4.0 kHz live sampling rate, 0.8 kHz bandwidth
nemi Struct G+ / Tilt + int. Flash As nemi Struct G+ / Tilt, additionally with internal flash memory to bridge longer radio interruptions of up to several minutes (e.g. roller coaster monitoring)
nemi Struct DAQ 2 Channel Wireless multi-sensor measurement system with two analog inputs, digital inputs, additional 9-DoF IMU and temperature sensor and integrated battery pack. Signal gain 1–128×, 2.5 V reference voltage, constant-current supply for Pt100 / Pt1000; 0–10 V option; max. 6.4 kHz live sampling rate, 24 bit
nemi Struct DAQ 3 Channel + int. Flash Three analog inputs, max. 1,296 Hz live sampling rate with 3 channels (multiplexed), otherwise as nemi Struct DAQ 2 Channel, additionally with internal flash memory
nemi Struct Solar Extension Replaces the internal battery pack with an external solar panel and a power bank as buffer storage for energy-autonomous SHM applications

Hardware Notes

  • M256 variant: nemi Struct G+ is now also available with the M256 main sensor (± 2 … 256 g, 16 bit).
  • Bridge excitation: the only supported Wheatstone bridge supply voltage is 2.5 V. A 1 V excitation option mentioned in older documentation is discontinued.
  • nemi DAQ nano hardware revisions: revision v2.0 requires a specific firmware build for reference-voltage (strain gauge) vs. reference-current (Pt100) mode; revision v2.1 sets the mode with a solder jumper. Both revisions are functionally identical once configured.

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio 1.1 (as of November 2026)
nemi Studio Web App 2026.11.04.3 (as of November 2026)
wirelessSensorPlot 7.4 (legacy, no longer maintained)
nemi Link 2400 Radio Channel Calculator Online tool, always current (replaces the Excel configuration tool)

FAQ

Applications

Is nemi Struct suitable for long-term bridge monitoring? Yes — this is its primary design target. It covers vibration, inclination, strain, displacement, crack and temperature monitoring with > 1 year battery runtime or unlimited runtime with the solar option.

Can nemi Struct be used for eigenfrequency identification? Yes. In an independent comparison against a calibrated piezoelectric reference accelerometer on a steel bridge, the eigenfrequency deviation was below 0.4 % for all measured modes.

Which variant do I need — G+ or DAQ? Use nemi Struct G+ when the measurands are acceleration, vibration, inclination and IMU data. Use nemi Struct DAQ when external sensors such as strain gauges, displacement sensors, temperature sensors, 0–10 V or digital sensors must be connected.

Can nemi Struct be used on ships or amusement rides? Yes. The IP66 housing withstands spray water (it is not intended for immersion). Data is buffered during short radio interruptions; the variants with internal flash bridge interruptions of up to several minutes.

Can I derive position from the accelerometer? In general, no. Double integration of acceleration accumulates errors quadratically due to unavoidable MEMS offsets. Use dedicated displacement sensors with nemi Struct DAQ.

Connectable Sensors

Which external sensors can be connected to nemi Struct DAQ? Wheatstone / strain gauge full bridges, potentiometric sensors, thermocouples (e.g. type K), thermistors, Pt100 / Pt1000, sensors with 0–10 V output (up to 2, optionally 3 analog channels) and up to 2 digital sensors with 3.3–24 V signal level. The analog input configuration is defined before delivery.

Can I connect a 4–20 mA sensor? Yes, with a precision shunt resistor that converts the current into a voltage within the input range.

Can geophones be connected? Yes, if signal conditioning and sampling rate are suitable. Check the sensor output type and the required bandwidth before wiring.

Can I connect a wind speed sensor? Yes, if the sensor provides a 0–10 V output.

Power Supply

How long does the battery pack last? 1.0 years for nemi Struct G+ at 125 Hz, 1.2 years for nemi Struct DAQ with 2 strain gauges (1,000 Ω) at 100 Hz and 1.5 years with 2 potentiometric displacement sensors (1,000 Ω) at 50 Hz — each in continuous live operation. Actual runtime depends on sampling rate, radio mode, temperature and active channels.

Can nemi Struct run on solar power in Central Europe? Yes. In a long-term test from January 2025 to February 2026 at 51° N, a vertically mounted 10 Wp panel with approx. 50 % sky shading supplied a nemi Struct DAQ (one analog channel at 100 Hz plus IMU) without interruption, starting in mid-winter with a largely discharged buffer.

Can I check the battery level remotely? Yes. Battery voltage is transmitted as a telemetry channel and is visible in nemi Studio / nemi Studio Web App and in the receiver data (e.g. nemi EdgeBase dashboard).

Does low temperature affect battery life? Yes, lithium cells deliver less usable capacity at low temperatures. The battery pack uses lithium thionyl chloride cells (Saft LS 33600), which perform well at low temperatures; the operating temperature range of nemi Struct is −20 to 60 °C.

Radio and Range

What wireless range can I expect? Up to 350 m with nemi Link 2400 XR at 125 kbit/s under favorable conditions. Faster radio modes have shorter ranges (see Range Considerations). Always validate the range on site.

What happens if a node temporarily loses radio contact? Data is buffered in the node and transmitted automatically when the connection is restored. The "+ int. Flash" variants bridge interruptions of up to several minutes.

Can more than 8 nodes connect to one receiver? Not on one radio channel. Use several receivers on separate channels.

Is LoRa a suitable alternative? Only for very low data rates. For vibration and SHM data at the sampling rates of nemi Struct, use nemi Link 2400 with a receiver that provides cellular backhaul (nemi EdgeBase or nemi Log with cellular option).

Maintenance

What should I check before replacing a battery pack that drained early? Compare internal temperature and battery voltage trends with other nodes, and check for water ingress, enclosure damage, cable glands, antenna condition and external sensor wiring. Abnormal heating together with fast battery drain often indicates a fault beyond normal battery depletion.

Integration

Is MQTT suitable for raw vibration data? No. MQTT on nemi EdgeBase is designed for aggregated values (min, max, mean per send interval). Retrieve raw data as binary files via FTP and decode them with the i4M Python decoders into pandas DataFrames.

Can I use my own MQTT broker? Yes. Any reachable MQTT broker can be configured on nemi EdgeBase; MQTT and MQTTS (TLS) are supported.

How is nemi Struct configured on nemi EdgeBase or nemi Log? Like the sensor node integrated in it: nemi Struct G+ like a nemi G+, nemi Struct DAQ like a nemi DAQ.

How accurate is the synchronization between nodes? Within one nemi Link 2400 network, ±10 µs with a stable radio connection. For analysis, align on the time counter column.

Which software do I need? nemi Sensor Config for the radio settings and nemi Studio or nemi Studio Web App for live data, sensor settings and recording. For unattended operation, the configuration files of the receiver (nemi EdgeBase, nemi Log) and the i4M decoders are used.