Skip to content

nemi Log

nemi Log

Description

nemi Log is a battery-powered, stand-alone wireless data logger whose battery life is maximized by the highly efficient nemi Link 2400 radio technology. It serves as receiver for up to eight wireless sensor nodes and simultaneously records data from its integrated 9-DoF IMU (3-axis accelerometer, gyroscope and magnetometer) and its multi-constellation GPS/GNSS module. With the integrated sensors, nemi Log can also be used on its own to measure accelerations, rotation rates, rotation angles and magnetic fields and to determine its position.

nemi Log is available in two versions:

  • nemi Log (basic) — all data is stored in binary format on a micro SD card, which is removed and read out on any PC.
  • nemi Log + cellular — additionally contains an LTE-M / NB-IoT modem. Data recorded and buffered on the SD card is uploaded automatically to an FTP server; status messages and time-aggregated data are sent via MQTT. Logger settings (e.g. sampling rate, active channels, gain) can be changed via a configuration file on the FTP server without physical access to the logger.

Measurements can run for a configurable duration with configurable pauses, follow a calendar schedule, start on a trigger condition or be started and stopped with the button. Data is time-stamped from the integrated real-time clock (RTC), the GPS/GNSS time or NTP.

In addition, nemi Log can be used as a USB receiver like a nemi Connect: connected to a PC, it passes the data of the sensor nodes to nemi Studio or the nemi Studio Web App (see USB Receiver Mode).

Within the nemione product family, nemi Log is the compact, self-contained field logger for deployments without a PC. For live PC-based measurements at high data rates, use nemi Connect; for Ethernet connectivity, edge computing, MQTT streaming of high-rate data or large local storage, use nemi EdgeBase.


Typical Applications

  • Temporary offline measurements — the basic version stores all data on the SD card; GNSS provides position tracking and an exact timestamp.
  • Stand-alone motion and position logging — without any external sensor node, the integrated IMU and GNSS record acceleration, rotation rate, magnetic field, position and time.
  • Rotating and moving applications — easy and flexible mounting makes nemi Log suitable for vehicles, UAVs / drones, rotating machine parts and transport monitoring. Data is buffered on the SD card when cellular coverage is unavailable.
  • Long-term monitoring with low data rates (+ cellular) — e.g. structural health monitoring (SHM) of cracks, inclination and deformation, where one value every few minutes is sufficient most of the time but high-rate raw data is required as soon as damage progresses (see MQTT Mode).
  • Long-term unattended monitoring — battery runtime of several weeks depending on configuration; continuous logging of 3 × nemi G+ at 4,000 Hz plus internal IMU at 208 Hz runs approx. 10 days. An external 7–30 V DC source on the EXT M8 connector enables permanent operation.
  • Multi-sensor setups — up to 8 wireless sensor nodes combined with the integrated IMU and GNSS from a single logger.

Technical Specifications

General

Parameter Value Unit
Dimensions (without antenna and connectors) 178 × 85 × 35 mm
Weight 446 g
Internal power supply Lithium-ion battery (6,000 mAh nominal) —
Runtime with full battery Depending on application; example: continuous logging (duty cycle 100 %) of 3 × nemi G+ at 4,000 Hz (three axes each) plus internal IMU at 208 Hz without GPS: 10 days —
Charging time (0–100 %) approx. 3 (at 15 W charging power) h
External power supply (USB-C) 5 V
External power supply (EXT M8) 7 – 30 V DC
Data logging on micro SD card (max. 32 GB), efficient binary format; Python decoder (pandas DataFrames, export to CSV, Parquet etc.) supplied free of charge —
Operating temperature −20 to 60 °C
Housing protection class IP 65 (with closed flap) —

Dimensions of nemi Log (all dimensions in mm)

Integrated 9-DoF IMU (ACC / GYR / MAG)

Parameter Value Unit
Sampling rate 208 / 104 / 52 Hz
Accelerometer ranges ± 16 / 8 / 4 / 2 g
Gyroscope ranges ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 °/s
Magnetometer ranges ± 16 / 12 / 8 / 4 Gauss
Signal resolution 16 bit

Satellite Navigation (GNSS)

Parameter Value Unit
GNSS module GPS / GLONASS / BeiDou / Galileo —
Sampling rate max. 10 Hz
Accuracy 1.5 m CEP

The GNSS operating mode (update rate, normal or low-power) is selected with gnss_mode (see GNSS Configuration).

Cellular Connection (+ cellular version only)

Parameter Value Unit
Data transmission FTP server, MQTT data streams —
Cellular modem LTE-M / NB-IoT —
Frequency range 700 – 2,200 MHz
LTE-M throughput (downstream / upstream) 300 / 375 kbit/s
NB-IoT throughput (downstream / upstream) 30 / 60 kbit/s
SIM form factor Nano-SIM —

In practice, LTE-M with good network coverage achieves approx. 120 kbit/s (approx. 8 KB/s); use this value for planning transfer times.

Parameter Value
Frequency band 2.4 GHz
Topology Star (nemi Log as receiver)
Max. sensor nodes 8 (nodes 1–3 in config.csv, nodes 4–8 in nodescon.csv)
Radio channel 0–79, default 0 (nemi_link_channel)
Radio modes 2 Mbit/s, 1 Mbit/s, 500 kbit/s (XR), 125 kbit/s (XR) (nemi_link_protocol)
Clock synchronization (sensor nodes to nemi Log) ±10 µs with a stable radio connection
Compatible sensor nodes nemi G+, nemi G+ nano, nemi G+ ultra, nemi G+ ultra nano, nemi DAQ, nemi DAQ nano, nemi Struct, nemi Motion

First Commissioning

Required Hardware and Software

Item Purpose
nemi Log or nemi Log + cellular Receiver and data logger
Antennas (included) RF (nemi Link 2400), GPS (active GNSS antenna), LTE (+ cellular version)
Micro SD card (≤ 32 GB, SPI-mode compatible) Data storage and configuration files; select the card in consultation with i4M
Nano-SIM (IoT SIM supporting LTE-M, NB-IoT as fallback) + cellular version only
Sensor nodes e.g. nemi G+, nemi DAQ
nemi Sensor Config v2.1 or later Persistent radio parameters of the sensor nodes via USB
config.csv (and optionally timeconf.csv, nodescon.csv) Logger configuration (see Detailed Configuration)
i4M Python decoder Decoding of the binary .bin files to pandas DataFrames / CSV
FTP server (+ cellular version) Raw data upload and remote configuration
Recommended: nemi Studio or nemi Studio Web App Verifying radio quality and sensor settings on site, using nemi Log in USB receiver mode or a nemi Connect

nemi Sensor Config, nemi Studio and the Python decoder are provided to customers via download links.

Step 1 — Prepare the Sensor Nodes

Configure each sensor node with nemi Sensor Config via USB (radio channel, radio mode, max. node count, unique node number). The channel and radio mode must match the settings in the nemi Log config.csv. See the commissioning section of the respective sensor node (e.g. nemi G+).

Step 2 — Prepare the nemi Log

  1. Switch the logger off — SD card and SIM card may only be inserted or replaced with the system switched off.
  2. Open the flap on the back panel.
  3. Insert the micro SD card (≤ 32 GB, SPI-mode compatible) into the push-push slot, contact pads facing the circuit board. When correctly inserted, the card does not protrude beyond the edge of the board. To eject, press the card briefly; it pops out a few millimetres.
  4. Copy a prepared config.csv (lowercase filename) to the root directory of the SD card, or use the fallback settings to verify basic operation.
    • cellular version: insert the activated nano-SIM (push-push slot, contact pads facing the circuit board). For purely offline operation, leave the SIM slot empty.
  5. Connect the antennas: RF (nemi Link 2400), GPS and — for the + cellular version — LTE.
  6. Charge the battery via USB-C (approx. 3 h at 15 W; the red charger LED goes out when charging is complete) or connect an external 7–30 V DC supply to the EXT M8 connector.

Step 3 — Start a Recording

  1. Switch the nemi Log on with the ON / OFF switch on the back panel.
  2. If USB is connected to a PC, the logger first waits up to 20 s for a USB connection (LED constant green with short red flashes; see USB Receiver Mode).
  3. The logger reads config.csv. With smart_logger_mode;0, the status LED flashes purple while the logger waits for a button input:
    • press < 3 s → single measurement (Mode 1),
    • press > 3 s (until the LED turns yellow) → automatic logging (Mode 2).
  4. Before a recording, the logger wakes the wireless sensor nodes (LED flashes yellow, approx. 30 s before recording) and sends them the sensor settings from config.csv.
  5. During recording, the LED flashes green irregularly for each successful SD write.
  6. After the recording, the sensor nodes are sent to sleep (LED flashes turquoise, approx. 20 s).
    • cellular version: when a cellular connection is due, the logger logs into the LTE network (LED flashes blue, 8–70 s depending on network and provider) and uploads data (LED flashes green irregularly).
  7. Verify that the first .bin data file appears on the SD card (filename format DDDSSSSS.BIN, see Data Formats and Decoding).

Close the flap after commissioning — full IP65 protection is only given with closed flap.

During commissioning in a new environment, check signal strength, missing samples and sampling rates at the intended installation positions before switching to standalone logging. Use nemi Log in USB receiver mode with nemi Studio or the nemi Studio Web App, or a nemi Connect. Do not hold the sensors in your hand during range tests — human body tissue strongly absorbs 2.4 GHz radio.

USB Receiver Mode

nemi Log can also be used like a nemi Connect, i.e. as USB receiver for live measurements with nemi Studio or the nemi Studio Web App:

  1. Connect the switched-off nemi Log to the USB port of the computer.
  2. Start nemi Studio (or open the nemi Studio Web App).
  3. Switch the nemi Log on. It registers as a virtual COM port (Windows plays the "new device" sound); the LED lights constant green with short red flashes.
  4. Within 20 seconds, refresh the COM port list (Refresh COM Ports), select the new COM port and connect. Otherwise the logger starts logging in its configured mode.
  5. From then on, the logger behaves like a nemi Connect — see the nemi Studio documentation.

USB throughput

In USB receiver mode, nemi Log has a lower USB throughput than nemi Connect on some host systems, so higher data rates may not be transferred without missing samples. nemi Studio shows the current USB transfer rate in the console of the main window: with nemi Connect it is usually above 5,000 kB/s; with nemi Log it can drop below 200 kB/s on some hosts. The dual-controller design of nemi Connect with a dedicated USB controller is compatible with all host systems. This limitation applies only to the USB receiver mode — logging to the SD card is significantly faster.

LED Status Codes

LED pattern Meaning
Constant green with short red flashes (0.5 s) Waiting for USB connection via COM port (only directly after switching on, if USB is connected to a PC; max. 20 s)
Red flashing (0.5 s) After switching on: micro SD card missing, or battery charge too low to supply LTE modem and SD card
Purple flashing (1 s) Waiting for input via button. Mode 1: waits for input; Modes 2, 3, 4: waits 10 s for an input, then continues in automatic mode
Yellow flashing (3 s) Wireless sensor nodes are woken up 30 s before the scheduled recording
Green irregular flashing during SD logging Data recording successful
Turquoise flashing (3 s) Wireless sensor nodes are sent to sleep for 20 s after recording
Blue flashing (5 s) LTE login (can take 8–70 s depending on network and provider)
Green irregular flashing during LTE data transmission LTE data transmission; 5 kB packets successfully transmitted
Green flashing once per second (Mode 4) Trigger monitoring active
5 × green / 5 × red (Mode 4) Trigger fired / trigger not fired within trigger_monitor_time

In addition, the back panel carries a charger LED (lights red while the internal battery is charging) and an RF status LED (currently without function).

Radio Channel and Range

The channel set in config.csv (nemi_link_channel) must match the channel of all sensor nodes. Channel 0 is the default. Channel 10 can be used as well, but is slightly less favorable than channel 0 because of potential WLAN interference. Two nemi Link 2400 networks on the same channel at the same location interfere with each other and cause data loss. Recommended channels for parallel networks are 0, 25, 50 and 75.

Radio mode (nemi_link_protocol) Typical range (indoor / urban)
0 — 2 Mbit/s (default) ~20 m / ~50 m
1 — 1 Mbit/s ~50 m / ~125 m
2 — 500 kbit/s (XR) ~90 m / ~225 m
3 — 125 kbit/s (XR) ~140 m / ~350 m

Lower data rates increase range but reduce the maximum achievable sampling rate. Verify the planned combination of sensors, sampling rates and radio mode with the nemi Link 2400 Radio Channel Calculator. See nemi Link 2400 for details.


Mounting & Connections

Mechanical Mounting

nemi Log has a ruggedized, weatherproof aluminium housing (IP65 with closed flap) and is intended for professional installation on machines, vehicles, buildings and structures. Do not operate the device in potentially explosive atmospheres.

Mount the device with the nemi Link 2400 antenna oriented away from large metal surfaces. In metal enclosures (e.g. gearbox casings that act as Faraday cages), route the antenna cable through a small opening so the antenna is inside the enclosure while the logger body remains outside, or vice versa. Place the GNSS antenna with a clear view of the sky.

Front Panel

Front panel of nemi Log

Interface Purpose
GPS (SMA) External, actively powered GNSS antenna (included)
EXT M8 External power supply 7–30 V DC and two digital/analog inputs (see below)
LTE (SMA) 4G/LTE antenna (+ cellular version, included)
RF (RP-SMA) nemi Link 2400 antenna for the sensor nodes (included)
Status LED Operating state (see LED Status Codes)

Back Panel (behind the flap)

Back panel of nemi Log

Interface Purpose
RF status LED Currently without function
Charger status LED Lights red while the internal battery is charging
Micro SD slot (push-push) Data storage and configuration files; card ≤ 32 GB, SPI mode
Nano-SIM slot (push-push) IoT SIM card for LTE-M with NB-IoT as fallback (+ cellular version)
USB-C Charging (5 V, 15 W) and USB receiver mode (see USB Receiver Mode)
Switch I / O Power ON / OFF
Button Start / stop of recordings depending on the operating mode

The elements used for setting up the logger are protected behind the flap. For full IP65 protection, the flap must be closed.

EXT M8 Connector

Pinout of the EXT M8 connector

Pin Wire colour Function Notes
1 Brown DC In Wide-range voltage input 7–30 V DC; powers the device and charges the internal battery
2 White DIN 1 Analog input 0–3.3 V, analog input 0–24 V, or digital input up to 24 V (usable as trigger for recording / transmission)
3 Blue GND Common ground
4 Black DIN 2 Same options as DIN 1; both pins must be configured identically

Wide-range voltage input (pins 1 and 3): for permanent installation (e.g. 24 V) or runtime extension with external batteries (e.g. SAFT LS cells in series or a 12 V car battery). The internal battery is constantly recharged and acts as an energy buffer.

Digital I/O (pins 2 and 4, on request): up to two digital sensors. Other interfaces (UART, I²C) can be connected as well; the implementation of the associated drivers including downstream data transmission (e.g. via MQTT) in the nemi Log firmware is available on request.

Power Supply Options

Source Connector Input voltage Notes
USB-C charger USB-C 5 V, ≥ 15 W approx. 3 h full charge; device can operate while charging
Industrial supply EXT M8 pins 1 / 3 7–30 V DC Continuous operation; internal battery recharges
Vehicle battery EXT M8 pins 1 / 3 12 V DC Suitable for mobile deployments
External primary battery pack EXT M8 pins 1 / 3 7–30 V DC e.g. 6 × SAFT LS 33600 D-cells in series for multi-year autonomous operation

Detailed Configuration

nemi Log is configured via CSV files — no PC software is required during operation.

Configuration Files and Priority

File Required for Content
config.csv always Logger, integrated sensors, radio, cellular / FTP and sensor nodes 1–3
timeconf.csv Mode 3 (calendar) Wake-up times and sampling rates for 28 days
nodescon.csv 8-sensor mode Configuration of sensor nodes 4–8

The nemi Log reads config.csv from three sources, in descending priority:

  1. FTP server (+ cellular) — file in the logger's folder Log_XXX (XXX = device serial number); downloaded at every LTE connection.
  2. Micro SD card — file in the root directory.
  3. Fallback settings stored in the microcontroller (always available).

If a configuration file exists both on the SD card and on the FTP server, the file on the SD card is overwritten automatically at the next FTP connection. Placing an updated file on the FTP server is therefore the standard mechanism for remote reconfiguration.

Lowercase file names

Name all configuration files in lowercase (config.csv, timeconf.csv, nodescon.csv). On an SD card that the logger has already written to, Windows may display the file names in uppercase; the logger still works with these files as long as they stay on the card. New files copied to the card must be named in lowercase.

config.csv File Structure

config_start
<parameter>;<value>
<parameter>;<value>
config_end
  • The first line config_start and the last line config_end are mandatory; the order of the parameters in between is arbitrary.
  • Delimiter: semicolon (;); all parameter names are lowercase.
  • If a parameter appears twice, the later line applies. Parameters that are not set use the fallback settings.

A complete example is given under Example config.csv.

Operating Modes

Parameter Values Description
smart_logger_mode 0 / 1 / 2 0 = Mode 1/2 (button press < 3 s: single measurement; > 3 s: automatic mode), 1 = Mode 3 (calendar), 2 = Mode 4 (trigger)
logging_time seconds Duration of data logging per cycle
sleep_time seconds Time until the next data acquisition
Mode Start Description
Mode 1 — Single measurement Button press (< 3 s) One logging cycle of duration logging_time with the first ODR value of each sensor; data is written to the SD card and, if due, transferred to the FTP server. With logging_time;0 and sleep_time;0, start and stop are controlled entirely by the button: pressing the button again during logging (green LED flashing) ends the logging and restarts the logger, which then waits for the next start (purple LED).
Mode 2 — Automatic / continuous Button press (> 3 s) Classic data logger mode: logging (logging_time), optional transmission, then sleep (sleep_time), repeated. The five ODR values per sensor are cycled through in the order 1, 2, 3, 4, 5, 1, 2, … after each wake-up.
Mode 3 — Calendar Long button press at first start Measurements and connections according to timeconf.csv (see below).
Mode 4 — Trigger Automatic Like Mode 2, but data is only logged if a trigger condition was met.

Notes on Mode 2:

  • sleep_time;0 enables the most continuous data acquisition possible. The logger no longer waits for button inputs and starts immediately in automatic mode; the sensor nodes are not sent to sleep between the intervals. At higher data rates, some samples may be lost between two intervals.
  • For sleep_time < 60 s, the sensor nodes do not enter sleep mode, since the wake-up / sleep sequence would not save energy.
  • If the logger is in the sleep phase, a button press wakes it up and is treated as the scheduled wake-up. If the last LTE connection is longer ago than cellular_connect_time, an LTE transfer is started as well.

Mode 3 — Calendar Mode

In Mode 3, the logger performs measurements and connections according to a calendar defined in timeconf.csv:

  1. Start with an empty SD card and copy the prepared config.csv and timeconf.csv (and nodescon.csv in 8-sensor mode) to it. Place the same files in the logger's FTP folder.
  2. Switch the logger on. When the LED flashes purple, press and hold the button until the LED changes colour, then release it (a short press starts Mode 1).
  3. The logger checks whether the current hour matches the next wake-up time. If not, it sleeps until the top of the next hour and checks again.
  4. At a wake-up time, the logger records data with the configured parameters. Afterwards, an LTE connection is always established (if a working SIM and network are available): NTP synchronization, MQTT telemetry, download of new settings and — if enabled — FTP upload. The logger then sleeps until the next wake-up time.

timeconf.csv format:

config_timetable_start
01;0,10,20;3,3,3;1,2,3
02;0,10,20;3,3,3;1,2,3
...
28;0,10,20;3,3,3;1,2,3
config_timetable_end
Field (separated by ;) Meaning
1 Calendar day 01–28 (4-week cycle)
2 Three wake-up times of the day as full hours, comma-separated
3 ODR codes of the primary sensor (nemi G+: accelerometer, sX_vib_odrs codes; nemi DAQ: analog measurement chain, sX_ad_odrs codes) for the three wake-ups
4 ODR codes of the secondary sensor (IMU, sX_imu_odrs codes) for the three wake-ups

This gives 3 × 28 = 84 wake-up times over the 28-day cycle.

  • All times are UTC; time zones are not taken into account.
  • If the first wake-up time of day 1 lies before the switch-on time, the first recording only takes place on the following day at that hour. Choose the first wake-up time after the planned switch-on time.
  • The sampling rate codes apply to all paired sensor nodes. If nemi G+ and nemi DAQ are operated together and the primary-sensor code is > 5, all nemi G+ nodes are automatically set to 4,000 Hz.

Mode 4 — Trigger Mode

Trigger mode works like automatic mode, but measurement data is only logged if a trigger condition was met beforehand. The trigger has no effect on the timing of the LTE connection.

Parameter Values Description
trigger_monitor_time seconds Duration of the trigger monitoring phase
trigger_sensor_id 0 = internal IMU; 1–3 (3-sensor mode) or 1–8 (8-sensor mode) Module whose signal is monitored
trigger_signal_id 0 = gyroscope (GYR), 1 = magnetometer (MAG) Monitored sensor
trigger_axis_id 0 = X, 1 = Y, 2 = Z Monitored axis
trigger_level bit code Threshold as absolute bit code, taking the selected measuring range into account. i4M provides customers with an Excel file for converting physical units to bit codes.

Sequence:

  1. After wake-up, only the trigger sensor is activated and its GYR or MAG data stream is monitored for trigger_monitor_time (LED flashes green once per second). The threshold applies in positive and negative direction.
  2. If the trigger fires (LED flashes green 5 ×), all configured nodes are switched on and the normal logging follows. If not (LED flashes red 5 ×), no data is logged.
  3. In both cases, the LTE connection is established according to the schedule, so that the logger reports regularly. The logger then sleeps for sleep_time.

Example — trigger on the gyroscope Z axis of the internal IMU at 750 °/s (GYR range ±2,000 °/s); the trigger fires at +750 °/s and at −750 °/s:

smart_logger_mode;2
trigger_sensor_id;0
trigger_signal_id;0
trigger_axis_id;2
trigger_level;10713

A digital input on the EXT M8 connector can also be used as trigger for recording / transmission.

Offline Mode (SD-Only Logging)

nemi Log also works without an LTE connection: the settings are taken from the configuration files on the SD card or from the fallback settings. Without a SIM card, the logger detects the missing SIM within approx. 5 s and does not attempt a connection.

Semi-offline mode: with cellular_transmit_active;0, no measurement data is sent to the FTP server, but telemetry (battery voltage, number of files on the SD card), time synchronization and remote configuration remain available.

If a SIM card is inserted, the logger connects to the LTE network after the first sampling interval and then at least once every 24 hours as a fallback, regardless of the parameters (see Cellular / LTE Configuration). Make sure that no conflicting configuration files are stored in the logger's FTP folder; otherwise they overwrite the settings on the SD card.

Internal Sensor Configuration

Parameter Values Description
logger_imu_odr 1 / 2 / 3 IMU sampling rate: 1 = 52 Hz, 2 = 104 Hz, 3 = 208 Hz
logger_imu_acc_range 0–4 Accelerometer range: 0 = off, 1 = ±2 g, 2 = ±4 g, 3 = ±8 g, 4 = ±16 g
logger_imu_gyr_range 0–6 Gyroscope range (see table below)
logger_imu_mag_range 0–4 Magnetometer range: 0 = off, 1 = ±4, 2 = ±8, 3 = ±12, 4 = ±16 Gauss

To disable the internal IMU completely, set all three range parameters to 0.

Gyroscope range codes (also used for the sensor nodes):

Code Range
0 Off
1 ±250 °/s
2 ±500 °/s
3 ±2,000 °/s
4 ±125 °/s
5 ±1,000 °/s
6 ±4,000 °/s

GNSS Configuration

gnss_mode Mode Update rate Position accuracy (CEP)
0 Off — —
1 Normal 10 Hz 1.5–2.5 m
2 Normal (default if not set) 1 Hz 1.5–2.5 m
3 Low power 1 Hz 2.0–3.0 m
4 Low power 0.1 Hz 3.0–5.0 m

The GNSS module increases the total power consumption of the logger by approx. 50 %. In modes 3 and 4, the consumption is approx. 10–20 % lower than in modes 1 and 2. For long-term applications where GNSS is not strictly required, switch it off (gnss_mode;0) to maximize battery life. With GNSS logging enabled, the Python decoder automatically synchronizes all internal and external sensor data to GNSS time.

Use gnss_mode;2 when reliable absolute timestamps are required; validate the data quality of the low-power modes 3 and 4 before long-term deployments.

Radio Settings

Parameter Values Description
nemi_link_channel 0–79 Radio channel; must match all sensor nodes (default 0)
nemi_link_protocol 0–3 Radio mode: 0 = 2 Mbit/s (default), 1 = 1 Mbit/s, 2 = 500 kbit/s (XR), 3 = 125 kbit/s (XR)
nemi_link_sensor_count 3 / 8 Number of sensor nodes: 3 (default) or 8 (requires nodescon.csv)

The sensor nodes are in ultra-low-power sleep mode and wake up every 30 s to look for a receiver. Approx. 30 s before a scheduled measurement, the logger starts sending the wake-up signal and transmits the sensor settings from config.csv. After logging, the sleep signal is sent for approx. 20 s, so that the nodes return to sleep mode.

Warning

Operating two i4M sensor nodes or receivers on the same radio channel and in the same pipe / time slot causes data loss and errors. The correct configuration of sensor nodes and receivers is the responsibility of the user.

Note: nemi Log units with older firmware require a firmware update for the extended-range modes (XR, protocols 2 and 3). This update cannot be applied via config.csv; contact i4M.

Sensor Node Configuration

Each sensor node is configured individually; sX stands for the node number (s1, s2, s3 in config.csv; s4 … s8 in nodescon.csv).

Parameter Values Description
sX_sensor_type 1 / 2 1 = telemetry module (nemi DAQ, nemi DAQ nano); 2 = wireless accelerometer (nemi G+, nemi G+ nano)
sX_ad_gains 0–7, 0–7, 0–7 Type 1: gain of the (max. 3) analog channels: 0 = off, 1 = 1×, 2 = 4×, 3 = 8×, 4 = 16×, 5 = 32×, 6 = 64×, 7 = 128×
sX_vib_range 0–2 Type 2: range of the primary accelerometer: 0 = ±2 g (M08) / ±10 g (M40), 1 = ±4 g / ±20 g, 2 = ±8 g / ±40 g
sX_imu_acc_range 0–4 Node IMU accelerometer: 0 = off, 1 = ±2 g, 2 = ±4 g, 3 = ±8 g, 4 = ±16 g
sX_imu_gyr_range 0–6 Node IMU gyroscope (codes as above)
sX_imu_mag_range 0–4 Node IMU magnetometer: 0 = off, 1 = ±4, 2 = ±8, 3 = ±12, 4 = ±16 Gauss
sX_din_high_level 6 × 0–3 High level of the 6 digital inputs
sX_ad_odrs 5 × 0–15 Type 1: analog sampling rate codes (see below)
sX_imu_odrs 5 × 0–7 Node IMU sampling rate: 0 = off, 1 = 52 Hz, 2 = 104 Hz, 3 = 208 Hz, 4 = 416 Hz, 5 = 833 Hz, 6 = 1,666 Hz, 7 = 3,332 Hz
sX_vib_odrs 5 × 0–5 Type 2: primary accelerometer: 0 = 4,000 Hz, 1 = 2,000 Hz, 2 = 1,000 Hz, 3 = 500 Hz, 4 = 250 Hz, 5 = 125 Hz

For the five ODR values: the first value is used in Mode 1 and Mode 4; in Mode 2, the values are cycled through (see Operating Modes). Parameters that do not apply to the sensor type (e.g. sX_vib_range for a nemi DAQ) are ignored.

  • nemi Struct: configured like the sensor node it contains — type 1 for a nemi DAQ, type 2 for a nemi G+.

nemi DAQ analog sampling rate (sX_ad_odrs): the resulting rate depends on the code and the number of active channels:

sX_ad_odrs Mode 1 channel 2 channels 3 channels
0 off off off off
1 High Res — 1,944 Hz 1,296 Hz
2 High Res 6,400 Hz 1,074 Hz 716 Hz
3 High Res 4,800 Hz 742 Hz 495 Hz
4 High Res 3,200 Hz 567 Hz 378 Hz
5 High Res 2,400 Hz 459 Hz 306 Hz
6 High Res 1,600 Hz 385 Hz 257 Hz
7 High Res 800 Hz 332 Hz 221 Hz
8 High Res 400 Hz 291 Hz 194 Hz
9 High Res 200 Hz 235 Hz 156 Hz
10 High Res 100 Hz 196 Hz 131 Hz
11 Ultra Low Power 100 Hz 100 Hz 100 Hz
12 Ultra Low Power 75 Hz 75 Hz 75 Hz
13 Ultra Low Power 50 Hz 50 Hz 50 Hz
14 Ultra Low Power 25 Hz 25 Hz 25 Hz
15 Ultra Low Power 1 Hz 1 Hz 1 Hz

8-Sensor Mode

config.csv configures only sensor nodes 1–3 and the integrated sensors. For up to 8 nodes, set nemi_link_sensor_count;8 and store the additional file nodescon.csv on the SD card and in the logger's FTP folder. It is structured like the sensor section of config.csv, starts with nodescon_start, ends with nodescon_end and contains nodes 4 to 8:

nodescon_start
s4_sensor_type;2
s4_ad_gains;0,1,1
s4_vib_range;0
s4_imu_acc_range;1
s4_imu_gyr_range;3
s4_imu_mag_range;0
s4_din_high_level;1,1,1,1,1,1
s4_ad_odrs;5,6,10,10,10
s4_imu_odrs;3,4,4,4,4
s4_vib_odrs;2,2,2,2,2
;
s5_sensor_type;2
...
nodescon_end

At maximum sampling rate (4,000 Hz, three axes), the practical limit is 3 nodes due to radio bandwidth.

Cellular / LTE Configuration (+ cellular)

Parameter Values Description
cellular_connect_active 0 / 1 1 = connect to LTE regularly to fetch new configurations, synchronize the time and send MQTT telemetry
cellular_transmit_active 0 / 1 1 = transmit measurement data to the FTP server during LTE connections; 0 = no measurement data transfer
cellular_deep_sleep_active 0 / 1 1 = modem deep sleep after each transmission (lower consumption, but the next LTE login takes longer). Deactivating deep sleep only speeds up logins if connections follow each other within a few minutes; otherwise leave it enabled.
cellular_sim_pin number PIN of the SIM card, if required
cellular_apn text APN of the SIM card (currently not evaluated — the APN stored on current IoT SIM cards is read automatically)
cellular_connect_time minutes Interval between LTE connections
cellular_transmit_time seconds Maximum duration of the data transmission per connection; the connection is closed earlier when all files have been transmitted

No logging takes place during an LTE transfer. Larger files (higher data rates, longer recordings) need correspondingly longer transmission times. If the configuration is changed frequently, do not set cellular_connect_time too long, so that changes on the FTP server are applied quickly.

Safety net

To prevent the remote configuration from being disabled by mistake, the logger establishes an LTE connection at least once every 24 hours, even with cellular_connect_active;0. If this fails, it retries at every wake-up until it succeeds (max. 120 s per attempt), which increases power consumption. Without SIM card, no attempt is made.

Cellular quality and speed depend on the distance to the cell tower, topography, buildings and weather. The provider also matters: LTE login times vary between 8 and 70 s, and long login times considerably increase energy consumption. In i4M tests, SIM cards from iBasis connected very fast; SIM cards from 1nce took significantly longer.

FTP and NTP Settings (+ cellular)

Parameter Description
ftp_ip_4_address FTP server IP address (IPv4 format)
ftp_port FTP port (typically 21)
ftp_user FTP username
ftp_password FTP password
ntp_ip_4_address NTP server IPv4 address for clock synchronization

After a successful transfer to the FTP server, the file is deleted from the SD card.

To retrieve a new config.csv from the FTP server quickly after the first start-up, enter the FTP credentials and use short logging cycles with frequent connections:

config_start
logging_time;10
cellular_connect_time;2
cellular_transmit_time;180
sleep_time;60
config_end

This produces 10-second log files, connects every 2 minutes, allows 3 minutes for the transfer and sleeps for 1 minute — making it straightforward to confirm the FTP upload before switching to the production configuration.

Example config.csv

config_start                  // mandatory first line
cellular_connect_active;1     // establish LTE connections
cellular_transmit_active;1    // transmit measurement data
cellular_deep_sleep_active;1  // modem deep sleep between connections
cellular_sim_pin;1234
ftp_ip_4_address;192.0.2.10   // IP address of the FTP server
ftp_port;21
ftp_user;my_user
ftp_password;my_password
ntp_ip_4_address;192.0.2.20   // NTP time server
nemi_link_channel;0           // radio channel
nemi_link_protocol;0          // 2 Mbit/s
nemi_link_sensor_count;3
smart_logger_mode;0           // wait for button: Mode 1 or Mode 2
logging_time;60               // 60 s of data logging
cellular_connect_time;10      // LTE connection if the last one is > 10 min ago
cellular_transmit_time;180    // disconnect after 180 s
sleep_time;600                // next measurement 600 s after the end of the cycle
logger_imu_odr;3              // internal IMU 208 Hz
logger_imu_acc_range;1        // ±2 g
logger_imu_gyr_range;2        // ±500 °/s
logger_imu_mag_range;0        // magnetometer off
gnss_mode;2                   // 1 Hz GNSS
;
s1_sensor_type;1              // nemi DAQ
s1_ad_gains;6,0,0             // channel 1: 64×, channels 2 + 3 off
s1_vib_range;0                // ignored (type 1)
s1_imu_acc_range;3            // ±8 g
s1_imu_gyr_range;0            // off
s1_imu_mag_range;1            // ±4 Gauss
s1_din_high_level;1,1,1,1,1,1
s1_ad_odrs;5,6,7,8,10         // Mode 1: 2,400 Hz; Mode 2: 2,400 / 1,600 / 800 / 400 / 100 Hz
s1_imu_odrs;1,7,5,4,2         // Mode 1: 52 Hz; Mode 2: 52 / 3,332 / 833 / 416 / 104 Hz
s1_vib_odrs;2,2,2,2,2         // ignored (type 1)
;
s2_sensor_type;2              // nemi G+
s2_vib_range;0                // ±2 g (M08)
s2_imu_acc_range;1
s2_imu_gyr_range;1
s2_imu_mag_range;1
s2_imu_odrs;3,4,4,4,4
s2_vib_odrs;2,2,2,2,2         // 1,000 Hz
config_end                    // mandatory last line

Power Consumption and Battery Life

Configuration Approximate runtime
3 × nemi G+ at 4,000 Hz + internal IMU 208 Hz, no GNSS, continuous ~10 days
Intermittent (e.g. 60 s on / 600 s off), hourly LTE, no GNSS several weeks
External power (7–30 V DC) unlimited

Enabling GNSS increases total power consumption by approximately 50 %. LTE login time (8–70 s depending on provider and signal) directly affects the energy per connection — in deployments with frequent connections, a SIM card with consistently fast login noticeably extends battery life.


Integration

Integration Architecture

nemi G+ / G+ ultra / DAQ / Struct / Motion sensor node(s)
    │  nemi Link 2400 (2.4 GHz wireless, up to 8 nodes)
    ▼
nemi Log (+ cellular)
    ├── Micro SD card  →  binary .bin files  →  Python decoder  →  pandas DataFrames / CSV
    ├── USB-C (USB receiver mode)  →  nemi Studio / nemi Studio Web App
    └── LTE-M / NB-IoT modem  (+ cellular only)
            ├── FTP upload  →  .bin files on FTP server  →  Python decoder
            └── MQTT  →  broker  →  database  →  dashboard

The basic version provides the SD card branch only; the + cellular version adds the modem for remote data delivery and remote configuration.

Logging Cycle (Mode 1 / 2)

  1. Wake-up.
  2. If USB is connected: wait 20 s for the COM port. If the COM port is opened, the logger acts as USB receiver; otherwise it continues.
  3. Read and apply the settings from config.csv.
  4. Standby (purple flashing) for 10 s; then Mode 1 waits for the next manual start, Mode 2 continues.
  5. Wake up the sensor nodes (yellow flashing).
  6. Logging (green flashing).
  7. Send the sensor nodes to sleep (turquoise flashing).
  8. Check whether a new LTE connection is due (cellular_connect_time); if not, continue with step 12.
  9. LTE login (blue flashing).
  10. LTE connection: MQTT telemetry, NTP synchronization, download of config.csv and timeconf.csv from the FTP server.
  11. File transfer to the FTP server (green flashing); close the connections.
  12. Sleep for sleep_time.

FTP Data Upload (+ cellular)

Each nemi Log has a unique serial number that determines the name of its folder on the FTP server (Log_XXX). It is recommended to give each nemi Log its own FTP login but let all loggers access the same directory — the data of all loggers is then collected in one place, each in its own subfolder.

FTP folder structure:

/
├── Log_001/
│   ├── config.csv       ← downloaded by the logger at each LTE connection
│   ├── timeconf.csv     ← required for Mode 3 (calendar scheduling)
│   ├── nodescon.csv     ← required for 8-sensor mode
│   └── DDDSSSSS.BIN     ← uploaded measurement data files
├── Log_002/
│   └── ...

The configuration files in a logger's folder can be edited on the FTP server; the logger downloads them automatically at the next connection ("remote access").

Transfer time planning: typical LTE-M throughput with good coverage is approx. 120 kbit/s (approx. 8 KB/s) — well below the nominal 375 kbit/s. A 60-second recording of 3 × nemi G+ at 4,000 Hz (three axes) plus IMU at 208 Hz generates approximately 3–5 MB, requiring 375–625 s of transfer time under good conditions. Set cellular_transmit_time with margin for variable coverage.

Interrupted transfers

The current firmware does not resume interrupted FTP transfers. If a file cannot be transferred completely within cellular_transmit_time, it is transferred again from the beginning at the next connection and overwritten on the server. The MQTT telemetry contains the number of files on the SD card — if it keeps increasing, extend cellular_transmit_time.

MQTT Status Data and MQTT Mode (+ cellular)

At each LTE connection, the logger sends MQTT telemetry, e.g. battery voltage and number of files on the SD card. This is independent of the FTP upload and of the cellular_transmit_active setting.

MQTT mode for long-term monitoring: In many SHM applications only little data is needed over long periods — e.g. one value every 20 minutes while crack, inclination or deformation progress is stable — but significantly higher temporal resolution (e.g. 100 Hz or more) is required as soon as progress accelerates. In MQTT mode:

  1. All paired sensor nodes and the nemi Log sleep, e.g. for 10 minutes, with very low energy consumption.
  2. nemi Log and all nodes wake up and briefly transmit samples, e.g. for 10 s.
  3. nemi Log calculates minimum, maximum and average values over all incoming channels and sends them via MQTT to a server, where they can be stored in a database and displayed on dashboards.

The MQTT mode can be combined with the normal transmission mode at any time, so that high-frequency raw data can also be transmitted as the damage progresses. i4M offers complete packages consisting of server infrastructure, database and dashboard; alternatively, any standard MQTT broker (e.g. Mosquitto, HiveMQ, AWS IoT Core, Azure IoT Hub) can be used.

Time Synchronization

Stage 1 — Wireless sensor network: sensor node clocks are synchronized to the nemi Log's reference clock via the nemi Link 2400 protocol with ±10 µs with a stable radio connection. With a poor connection, individual synchronization events have to be discarded because their transit time is too long. Synchronization happens automatically and requires no configuration.

Stage 2 — Absolute time reference: the nemi Log's own clock (RTC) is anchored to absolute time via:

  • GNSS (gnss_mode ≥ 1): when decoding, the Python decoder synchronizes all internal and external sensor data to GNSS time. Multiple nemi Log units at different locations can thus be time-aligned without depending on cellular NTP.
  • NTP (ntp_ip_4_address): at each LTE connection, the logger synchronizes its clock to the configured NTP server.

Stage 2 does not affect the relative alignment of the sensor nodes (already locked via Stage 1); it determines how the logger's reference clock is anchored to UTC, which matters when multiple loggers must be mutually aligned.

Data Formats and Decoding

Binary .bin Files

For each logging period (logging_time), the logger creates one file containing all sensors configured in config.csv. To keep the files small for LTE transfer, the data is stored in an efficient binary format: the COBS-encoded data messages of the sensors (the same format as the USB stream of a nemi Connect), separated by 0 bytes. Each data message carries the synchronized timestamp (32-bit timecounter, 1 µs resolution) of its last sample; the timestamps of the other samples follow from the sampling rate. The complete protocol documentation is provided to customers on request; i4M discloses the protocol to its customers.

Filename convention DDDSSSSS.BIN: DDD = day of year (001–366), SSSSS = second of the day at file creation (00000–86399). Files sort chronologically by name.

Python Decoder

i4M provides Python decoders, uniformly for the .bin files of the nemi Log and the .bin.bz2 files of the nemi EdgeBase. The decoder first converts all data streams of a file into pandas DataFrames, which can then be saved as CSV, Parquet etc. or processed directly in a Python environment. It is distributed as three Python files:

File Purpose
i4m_log_decoder.py Main decoder module
i4m_log_decoder_test.py Test file with usage examples
i4m_messages_handling.py Helper functions for decoding nemi Link 2400 USB data messages

Dependencies: Python 3 with numpy, pandas and cobs (pip install numpy pandas cobs).

Quick test: copy a .bin file into the decoder folder, open i4m_log_decoder_test.py in a Python development environment (e.g. Visual Studio Code), set the variable file_to_decode to the file name and run the script. The function decode_nemi_log_bin_file returns one pandas DataFrame per sensor data stream:

from i4m_log_decoder import decode_nemi_log_bin_file

result = decode_nemi_log_bin_file("path/to/DDDSSSSS.BIN")
# Returns a dict of pandas DataFrames, one per data stream, e.g.
# result["imu_data_1"]        — internal IMU (ACC / GYR / MAG)
# result["vibration_data_1"]  — wireless node 1
# result["gnss_data"]         — GNSS position + timestamp (if enabled)

for name, df in result.items():
    df.to_csv(f"{name}.csv", index=False)

For a quick look at the CSV files, the free FlowCSV Viewer (Microsoft Store) is recommended:

Decoded internal IMU data of a nemi Log in FlowCSV Viewer

Always use the latest decoder version from i4M. The decoder is versioned independently of the firmware; existing .bin files can be reprocessed with a newer decoder without re-recording.

Physical units are applied automatically. The first approximately 30 rows may contain stale samples from the sensor's startup buffer and should be discarded before analysis (df = df.iloc[30:]).

Each sensor stream has its own timestamp column. To combine streams on a common time axis, resample by interpolation (e.g. pandas reindex(...).interpolate("time")).

32-Bit Timecounter

The timecounter is a 32-bit unsigned integer at 1 MHz resolution and overflows after 2³² µs ≈ 71 min 35 s. The current Python decoder corrects the overflow automatically. For custom pipelines:

OVERFLOW_THRESHOLD = 4_000_000_000   # counts
OVERFLOW_VALUE     = 4_294_967_296   # 2^32

overflow_offset = 0
prev_tc = 0
corrected = []
for tc in raw_timecounter:
    if tc < prev_tc - OVERFLOW_THRESHOLD:
        overflow_offset += OVERFLOW_VALUE
    corrected.append(tc + overflow_offset)
    prev_tc = tc

Divide by 1,000,000 to convert counts to seconds, then add the epoch from Info.csv.

Info.csv Recording Metadata

At the start of each recording session, nemi Log writes an Info.csv file to the SD card with recording start time (UTC), logger serial number, firmware version and active sensor configuration. For deployments without GNSS, Info.csv is the primary absolute time reference. It may not be uploaded to the FTP server in all firmware versions — retrieve it from the SD card when physical access is available.

Large Files

At high sampling rates, files grow quickly (several GB per hour for 3 × nemi G+ at 4,000 Hz). Files exceeding the available RAM cause the Python decoder to fail. Set logging_time to produce files of manageable size (e.g. 600 s for high-rate deployments) or use the chunk-based decoding of current decoder versions (see i4m_log_decoder_test.py).

nemi Log vs. nemi Connect

Feature nemi Log nemi Connect
Standalone logging (SD card) Yes No — requires a host
Live display with nemi Studio / Web App Yes, in USB receiver mode (USB throughput can be limited on some hosts) Yes (dedicated USB controller, > 5,000 kB/s)
Cellular upload (FTP / MQTT) Yes (+ cellular version) No
Remote configuration Yes (FTP) No
Integrated IMU and GNSS Yes No
Best use case Standalone field deployment Live commissioning, lab, PC-based measurement at high data rates

The two devices are complementary: use nemi Connect (or nemi Log in USB receiver mode) during commissioning to verify radio quality and sensor settings, then deploy nemi Log for autonomous operation.


Troubleshooting

Radio and Connectivity

Symptom Likely cause Resolution
Gaps or missing samples in decoded data Weak radio link, metal shielding, channel conflict or sampling rate too high for the radio mode Optimize antenna orientation (verify live with nemi Studio, via USB receiver mode or nemi Connect); route the antenna out of metal enclosures; check that no other network uses the same channel; reduce the radio speed or sampling rate
Yellow LED wake-up sequence completes, but a node delivers no data Node battery depleted, node switched off, or channel / radio mode mismatch Check the node: in sleep mode it flashes green briefly every 10 s; recharge the node; verify nemi_link_channel and nemi_link_protocol against the node settings (nemi Sensor Config)
Missing samples in USB receiver mode only Limited USB throughput of nemi Log on this host Check the USB transfer rate in the nemi Studio console; reduce data rates or use a nemi Connect

Power and Startup

Symptom Likely cause Resolution
Red LED flashing (0.5 s) after switching on Micro SD card missing, incompatible or not fully seated; battery charge too low Insert the SD card until it clicks; charge via USB-C; use a card ≤ 32 GB that supports SPI mode
Logger waits after switching on (green with red flashes) USB connected — the logger waits up to 20 s for the USB receiver connection Wait 20 s, or disconnect USB if USB receiver mode is not intended
Charger LED lights red Battery is charging Wait until the LED goes out before a long field deployment

Configuration

Symptom Likely cause Resolution
Logger uses fallback settings / ignores config.csv Wrong or uppercase filename, file structure error, or a config.csv on the FTP server overrides the SD card Filename exactly config.csv (lowercase); first line config_start, last line config_end, semicolon delimiter; update or remove the FTP version if the SD card version should apply; check the debug files on the SD card to see which settings were applied
Remote configuration does not take effect No successful FTP connection yet Temporarily reduce cellular_connect_time (see Quick-Start Configuration); check the FTP credentials
Calendar mode does not record at the expected time Times are interpreted as UTC; first wake-up time was before switch-on Convert local times to UTC; set the first wake-up time after the switch-on time

Cellular / FTP

Symptom Likely cause Resolution
Files accumulate on the SD card; MQTT file count keeps growing cellular_transmit_time too short, weak LTE signal, files too large or incorrect FTP credentials Increase cellular_transmit_time; reduce logging_time or data rates; improve the LTE antenna position; verify ftp_ip_4_address, ftp_port, ftp_user, ftp_password
LED flashes blue, then green for a few seconds, then blue again — repeated up to 20 times FTP connection problem, typically passive FTP transfer without PASV information Enable passive mode (PASV) on the FTP server and open the data ports. The attempts count toward cellular_transmit_time.
Logger no longer reports online and cannot be reconfigured A faulty config.csv (e.g. wrong FTP credentials) prevents the logger from fetching a corrected configuration Automatic recovery (see below)

Fallback settings and recovery: default values are stored in the microcontroller (documented in the i4M settings list — an Excel file provided to customers — column "Value for Reset Settings"). If the logger has not had a successful LTE connection for 24 hours, it automatically attempts a connection with these defaults — regardless of the current config.csv. They contain the login data of the i4M FTP server, where a corrected config.csv can be provided; contact i4M (info@nemi.one, +49 (0) 241 56 00 22 00). Correct the faulty config.csv as soon as possible; otherwise the logger reloads it and has to go through the recovery procedure again (24 hours until the next attempt).

Remote SD card erase (last resort): with sd_card_erase;1, all measurement data (xxxyyyyy.BIN) and the config.csv are deleted from the SD card. The logger continues with the fallback settings, connects to the FTP server stored in them and downloads a new config.csv.

Warning

Immediately after the SD card erase, set sd_card_erase;0 (or remove the line) on the FTP server. Otherwise the logger erases its SD card — including the new config.csv — again at the next LTE connection.

Data and Decoder

Symptom Likely cause Resolution
Internal IMU timestamps do not align with wireless sensor timestamps Bug in an early decoder version (internal IMU sync only) Update the Python decoder; reprocess existing .bin files
Decoder crashes with a memory error File larger than available RAM Use chunk-based decoding; shorten logging_time (e.g. 600 s)
Backward timestamp jumps after ~71 minutes Unhandled 32-bit timecounter overflow in old decoder versions Update the decoder; or apply the manual overflow correction using the Info.csv start time
Timestamps not in absolute UTC No GNSS and no NTP synchronization available Use the timecounter for relative analysis; enable GNSS or LTE/NTP for absolute time
GNSS timestamps missing or erratic Poor sky view of the GNSS antenna, or low-power gnss_mode 3 or 4 Improve the GNSS antenna position; switch to gnss_mode;2 (1 Hz, normal mode)
Gaps between consecutive recordings with sleep_time;0 Known behaviour at higher data rates in continuous mode Expected; plan for short gaps between intervals

Product Changes

Versions

Version Description
nemi Log (basic) SD card logging, integrated IMU and GNSS
nemi Log + cellular Additionally LTE-M / NB-IoT modem for FTP upload, MQTT and remote configuration

Firmware v9.0 (February 2026)

Documented in the operating instructions v4.0 (April 2026):

  • gnss_mode parameter introduced (values 0–4): configurable update rates (10 Hz, 1 Hz, 0.1 Hz) and power modes (normal, low power); default 2 if not set. With GNSS logging, the decoder synchronizes all data to GNSS time.
  • Button stop in Mode 1: with logging_time;0 and sleep_time;0, start and stop of the recording are controlled entirely by the button.

Firmware Changes (May 2024)

  • SIM card detection: every connection attempt first checks for a working SIM card (approx. 5 s); without SIM, the attempt is aborted instead of waiting for a timeout of more than 60 s.
  • sleep_time;0 enables continuous recording; the logger starts directly in automatic mode without waiting for button input.
  • Sensor node sleep disabled for sleep intervals < 60 s, so that the node wake-up sequence does not consume the entire sleep interval.

Compatibility Notes

  • The Python decoder is versioned independently of the nemi Log firmware. Newer files may require a decoder update if the message format changed — always use the latest decoder from i4M.
  • Extended-range radio modes (XR, nemi_link_protocol 2 and 3) require a suitable firmware version that cannot be installed via config.csv.
  • Micro SD cards must be ≤ 32 GB and support SPI mode.
  • In USB receiver mode, high-rate live streaming is more reliable with a nemi Connect.

Software Tools Version Reference

Tool Version reference
nemi Sensor Config 2.1 (as of March 2024)
nemi Studio (USB receiver mode / commissioning) 1.1 Beta 2 (as of November 2026)
nemi Log firmware v9.0 (February 2026)
nemi Log operating instructions Document version 4.0 (April 2026)
nemi Link 2400 Radio Channel Calculator Online tool, always current (replaces the Excel configuration tool)

FAQ

Applications

Can nemi Log be used without external wireless sensors? Yes. The integrated 9-DoF IMU and GNSS module record acceleration, rotation rate, magnetic field, position and time without any sensor node.

Can nemi Log be used for long-term unattended monitoring? Yes. With continuous high-rate logging (3 × nemi G+ at 4,000 Hz + internal IMU at 208 Hz), the battery lasts approx. 10 days. With intermittent logging (e.g. 60 s on / 600 s sleep) and hourly LTE connections, runtime extends to several weeks. Connect an external 7–30 V DC source via the EXT M8 connector for permanent operation.

Is nemi Log suitable for rotating machinery (wind turbines, gearboxes, mills)? Yes. Mount the device on or near the rotating component. The integrated gyroscope and accelerometer provide rotation rate and angle information; choose the IMU sampling rate high enough that no rotation is missed. For metal enclosures, route the antenna cable through a small opening so the antenna is inside while the logger remains outside.

Can nemi Log be used for structural monitoring (bridges, buildings, foundations)? Yes. Use wireless sensor nodes such as nemi G+ or nemi Struct for vibration and tilt measurement. With the + cellular version and MQTT mode, long-term monitoring with low data rates and event-driven high-rate recordings is possible.

Can nemi Log be used for transport monitoring (ships, trucks, rail, drones)? Yes. For offline transport, data is stored on the SD card and retrieved after the journey. The + cellular version uploads data at configurable intervals and buffers data on the SD card when coverage is unavailable. Enable gnss_mode to record position alongside the sensor data.

Connectable Sensors

Which wireless sensor nodes are compatible? All nemione sensor nodes of the nemi Link 2400 network: nemi G+, nemi G+ nano, nemi G+ ultra, nemi G+ ultra nano, nemi DAQ, nemi DAQ nano, nemi Struct and nemi Motion. Up to 8 nodes per nemi Log.

Can sensors be connected directly to nemi Log? Up to two digital or analog signals (0–3.3 V, 0–24 V or digital up to 24 V) can be connected to the EXT M8 connector, e.g. as trigger. Other sensors (strain gauges, Pt100, geophones, etc.) are connected to a nemi DAQ wireless node; for geophones, check output voltage, impedance and damping requirements before selecting the gain.

What is the measurement uncertainty? This depends on the sensor node. For nemi G+, the static inaccuracy is < 8 % of the measuring range without calibration; factory calibration (on request) reduces it to < 0.1 % (M08) or < 1 % (M40, M256).

Power Supply

Which external power sources can I use? Any 7–30 V DC source on the EXT M8 connector (pin 1 brown = DC In; pin 3 blue = GND): 24 V industrial supplies, 12 V vehicle batteries or external primary battery packs. A pack of 6 × SAFT LS 33600 D-cells in series provides more than one year of runtime in a typical hourly-cycle application. The internal battery recharges and buffers brief power interruptions.

How does the SIM card affect battery life? LTE login takes 8–70 s depending on provider, location and signal. Longer login times consume proportionally more energy per connection; a SIM card with consistently fast login extends battery life in deployments with frequent connections.

Why does GNSS reduce battery life? The GNSS module increases the total power consumption by approx. 50 %. Switch it off with gnss_mode;0 if position or GNSS time is not required, or use the low-power modes 3 / 4.

Radio and Range

What is the maximum wireless range to the sensor nodes? Up to 350 m depending on radio mode and environment. Indicative figures (indoor / urban): ~20 / 50 m at 2 Mbit/s, ~50 / 125 m at 1 Mbit/s, ~90 / 225 m at 500 kbit/s, ~140 / 350 m at 125 kbit/s. Lower data rates reduce the maximum achievable sampling rate.

How many sensor nodes can operate simultaneously? Up to 8, with nemi_link_sensor_count;8 and nodescon.csv for nodes 4–8. At maximum sampling rate (4,000 Hz, three axes), the practical limit is 3 nodes due to radio bandwidth.

Can several loggers operate in the same area? Yes, if each logger with its sensor nodes uses its own radio channel (e.g. 0, 25, 50, 75). Two receivers or sensor nodes on the same channel and in the same time slot cause data loss.

Integration

Which IoT SIM card should I use? Any activated nano-SIM supporting LTE-M (preferred, significantly faster) with NB-IoT as fallback, e.g. from iBasis or 1nce. The APN is read automatically from the SIM card.

Do I need special software to read the data? Yes. The logger writes binary .bin files, which are decoded with the i4M Python decoder (free of charge, provided via download link) into pandas DataFrames; these can be saved as CSV, Parquet etc. or processed directly in Python.

Does nemi Log record data while uploading? No. No logging takes place during the LTE transfer.

Can I integrate nemi Log data into a SCADA or IoT platform? Yes, via standard MQTT (status and aggregated values) and FTP (raw binary data). No proprietary protocols are used — any compliant MQTT broker works. A lightweight adapter layer transforms the decoded data or MQTT payloads into the target platform's format.

Can I reconfigure the logger remotely? Yes, with the + cellular version. Place an updated config.csv in the logger's FTP folder (Log_XXX); the logger downloads and applies it at the next LTE connection. If the logger has lost connectivity due to a misconfiguration, the automatic 6-hour recovery procedure connects to the i4M FTP server using the fallback settings.

Can I view live data from nemi Log in nemi Studio? Yes, in USB receiver mode: connect the switched-off logger via USB, start nemi Studio or the nemi Studio Web App, switch the logger on and connect to its COM port within 20 s. For high data rates, a nemi Connect offers a higher USB throughput.

How are multiple loggers time-aligned? Within each radio network, the sensor nodes are synchronized to their logger (±10 µs with a stable radio connection). Several loggers are aligned to absolute time via GNSS (decoder synchronizes all data to GNSS time) or NTP during the LTE connections.