nemi G+ ultra nano¶

Description¶
nemi G+ ultra nano is a compact OEM sensor module in the form of a circuit board for wireless, highly dynamic and broadband measurement of vibration, oscillation and acceleration. It contains the same measurement electronics, firmware and data format as the housed nemi G+ ultra: a high-speed triaxial capacitive MEMS accelerometer with live sampling rates up to 26.7 kHz and a signal bandwidth from 0 Hz (static) up to 6.7 kHz (−3 dB), a 9-DoF IMU (accelerometer, gyroscope, magnetometer), an internal temperature sensor and the proprietary nemi Link 2400 radio interface — on a board of 30 × 30 mm. This documentation applies to hardware revision 1.2 and later.
Steep anti-aliasing filters implemented on the onboard MCU allow high bandwidths even at lower sampling rates, e.g. 1.17 kHz at 3.333 kHz sampling rate. This allows the bandwidth requirements of ISO/DIN ISO 20816 and DIN ISO 2954 to be met. The additional IMU captures angular rates and magnetic fields at the same time and thus the spatial orientation, which can save additional rotation-angle sensors in rotating applications.
The module is intended for integration into small installation spaces, custom sealed sensors and customer products. It is powered via the BAT pin (by default a rechargeable Li-ion battery, charged by the onboard charger via micro-USB; alternatively non-rechargeable batteries), via the DCIN wide-range input (5 – 30 V DC) or via micro-USB. An aluminum baseplate, a cover and a potted waterproof housing can be ordered additionally (not included as standard).
nemi G+ ultra nano requires a compatible nemi Link 2400 receiver: nemi Connect, nemi Log or nemi EdgeBase. Ranges of up to approx. 125 m are achieved in the 1 Mbit/s mode. Buffered data transmission bridges radio interruptions of up to several minutes without lost samples. Data can be transmitted as live raw samples or as "smart data" pre-evaluated by edge computing on the onboard 64 MHz 32-bit MCU.
ESD sensitive device
The board has limited built-in ESD protection. Devices subjected to high-energy electrostatic discharge may be damaged. Take proper ESD precautions when handling the module.
Typical Applications¶
- NVH (noise, vibration, harshness) measurements with signal content up to 6.7 kHz.
- Monitoring of motors, pumps, bearings and gearboxes, including standard-compliant measurements according to ISO/DIN ISO 20816 and DIN ISO 2954.
- Rotating or moving components such as rotor shafts of wind turbines or test benches.
- OEM integration — building compact, sealed custom sensors or turning components and machines into smart products.
- Installations inside metal structures, where the board can be placed in a custom enclosure close to the measuring point and an external antenna is connected via the u.FL connector.
Technical Specifications¶
General¶
| Parameter | Value | Unit |
|---|---|---|
| Dimensions with connectors | 30 × 30 × 12 | mm |
| Dimensions without connectors | 30 × 30 × 4.2 | mm |
| Weight (with connectors) | 6.5 | g |
| Operating temperature (board) | −25 to 85 | °C |
| Onboard MCU (usable for edge computing) | 64 MHz 32-bit MCU, 1 MB Flash, 256 KB RAM, hardware crypto features | — |
| Housing protection class | Without housing (cover and waterproof housing available, see Mounting) | — |
| Board dimensions | Board rendering |
|---|---|
![]() |
![]() |
(All dimensions in mm)
Power Supply¶
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage on BAT pin — rechargeable battery | 3.3 – 4.2 | V |
| Supply voltage on BAT pin — non-rechargeable battery, power bank, other DC source | 3.3 – 5 | V |
| Supply voltage on DCIN pin | 5 – 30 | V |
| USB power (charging, power supply, configuration) | 5 (micro-USB) | V |
| Charging cut-off voltage (secondary battery) | 4.2 | V |
| Charging current (secondary battery) | 120 | mA |
Main MEMS Accelerometer¶
| Parameter | Value | Unit |
|---|---|---|
| Sensor type | High-speed, low-noise, triaxial capacitive MEMS accelerometer | — |
| Selectable sampling rates | 26.666 (one axis) / 13.333 / 6.666 / 3.333 | kHz |
| Sampling-rate stability (full temperature range) | ± 50 | ppm |
| Realizable −3 dB bandwidths | 6.72 / 4.66 / 2.35 / 1.17 | kHz |
| Selectable measuring ranges | ± 16 / 8 / 4 / 2 | g |
| Sensor resonance frequency | 6.9 | kHz |
| Signal resolution | 16 | bit |
| Static 3D inaccuracy without calibration (related to measuring range) | < 2 | % |
| Static 3D inaccuracy with calibration (on request) | < 0.5 | % |
| Axis activation | X, Y, Z individually switchable | — |
Frequency Responses¶
| Sampling rate | Frequency response |
|---|---|
| 26.666 kHz | ![]() |
| 13.333 kHz | ![]() |
| 6.666 kHz | ![]() |
| 3.333 kHz | ![]() |
Secondary 9-DoF IMU (ACC / GYR / MAG)¶
| Parameter | Value | Unit |
|---|---|---|
| Sensor type | 9-DoF MEMS IMU: 3-axis accelerometer, 3-axis gyroscope, 3-axis magnetometer | — |
| Sampling rate | 104 | Hz |
| Signal resolution | 16 | bit |
| IMU accelerometer ranges | ± 16 / 8 / 4 / 2 | g |
| IMU gyroscope ranges | ± 4,000 / 2,000 / 1,000 / 500 / 250 / 125 | °/s |
| IMU magnetometer ranges | ± 16 / 12 / 8 / 4 | Gauss |
Internal Temperature Sensor¶
| Parameter | Value | Unit |
|---|---|---|
| Sampling rate | 1 | Hz |
| Measuring range | −20 to 60 | °C |
| Resolution | 0.1 | °C |
Radio (nemi Link 2400)¶
| Parameter | Value |
|---|---|
| Frequency band | 2.4 GHz |
| Topology | Star (one receiver per channel) |
| Radio range with nemi G+ ultra nano | up to approx. 125 m (1 Mbit/s mode) |
| Data buffering | Bridges radio interruptions of up to several minutes without lost samples |
| Antenna connector | u.FL, for an external 2.4 GHz / 50 Ω antenna |
| Compatible receivers | nemi Connect, nemi Log, nemi EdgeBase |
Radio modes and range with nemi G+ ultra nano: Due to its high sampling rates, nemi G+ ultra nano can use the slow long-range modes only to a limited extent. The 125 kbit/s mode is practically not usable.
| Radio mode | Typical range (in buildings / urban environment) | Usability with nemi G+ ultra nano |
|---|---|---|
| 2 Mbit/s | ~20 m / ~50 m | All sampling rates (observe the node and axis limits per sampling rate) |
| 1 Mbit/s | ~50 m / ~125 m | Reduced sampling rates / node count: one sensor at 13.333 kHz (one axis) or 6.666 kHz (all axes); three sensors at 6.666 kHz (one axis) or 3.333 kHz (two axes). 26.666 kHz only marginal. Verify with the nemi Link 2400 Radio Channel Calculator |
| 500 kbit/s | ~90 m / ~225 m | Only one sensor per channel (1-node mode) at 6.666 kHz (one axis) or 3.333 kHz (all axes); three sensors only at 3.333 kHz with one axis; verify on site |
| 125 kbit/s | ~140 m / ~350 m | Practically not usable (even 3.333 kHz with one axis in 1-node mode is marginal) |
Range values are taken from nemi Link 2400 and depend strongly on antenna orientation, metal structures and 2.4 GHz interference; always validate the range on site.
First Commissioning¶
Required Hardware and Software¶
| Item | Purpose |
|---|---|
| nemi G+ ultra nano (bare board, or on the optional baseplate, with cover or in waterproof housing) | Sensor node |
| Power source (Li-ion battery with protection circuit, primary cell or DC supply) | Power supply via BAT or DCIN pin |
| 2.4 GHz / 50 Ω antenna with u.FL connector (directly or via adapter cable) — only antennas approved by i4M (not included as standard, available on request) | Radio link |
| nemi Connect / nemi EdgeBase / nemi Log | Receiver (firmware must support the nemi G+ ultra data format) |
| Micro-USB cable (data-capable, not charge-only) | USB configuration and charging |
| nemi Sensor Config v2.1 or later | Radio and node configuration via USB |
| nemi Studio v1.1 or later, or nemi Studio Web App | Live display, FFT, sensor configuration and CSV recording |
Antenna required — use only approved antennas
Before operating the radio, an antenna must be connected to the u.FL connector of the board. No antenna is included as standard; i4M supplies approved antennas on request. Only antennas approved by i4M may be used — please ask i4M for approved antennas.
Step 1 — Check the Power Configuration¶
- Before connecting any power source, check the two solder jumpers on the top side of the board (see Power Supply Configuration). Both closed (default) = charger active, for rechargeable Li-ion batteries only. Open them before connecting a non-rechargeable battery.
- Connect the power source to the terminal block: GND + BAT (3.3 – 5 V) or GND + DCIN (5 – 30 V DC).
- Set the slide switch: top = BAT, bottom = DCIN. In the other position the module is off (or switches to the other source if both are connected).
- For a first bench test, the module can also be powered and charged via micro-USB. The solid red LED indicates charging; the red LED turning off indicates a full battery.
Step 2 — Configure the Sensor via USB¶
Radio parameters (channel, radio mode, node number, maximum nodes) are written with nemi Sensor Config over micro-USB. The procedure is identical to the nemi G+:
- Switch the module off with the slide switch and connect the micro-USB cable to the PC.
- Launch nemi Sensor Config and switch the module on. The LED cycles white → green → red → blue (restart), then shows solid green + flashing yellow (USB detected; waiting for COM port).
- Click Connect COM-Port within approximately 10 seconds. The LED changes to solid green + flashing blue.
- Enter the radio parameters and click Set nemi Link Parameters. After 10 s the module starts radio transmission with the new parameters.
Recommended first-test radio settings:
| Parameter | Recommended value | Notes |
|---|---|---|
| nemi Link 2400 Mode | 2 Mbit/s | Required for the highest sampling rates |
| nemi Link 2400 Node Count | 1 (low latency) for 26.666 kHz; 3 for multi-sensor setups | See Sampling Rate, Axes and Node Count |
| nemi Link 2400 Channel | 0 (other preferred channels are 25, 50, 75) | Default; avoids busy Wi-Fi subbands |
| nemi Link 2400 Node Number | 1 | Unique per sensor on the same channel |
Important: For 26.666 kHz, sensor and receiver must be in 1-node (low latency) mode and only one axis may be active.
Step 3 — Set Up the Receiver and Verify Data¶
- Launch nemi Studio (or the nemi Studio Web App) and plug in the nemi Connect (or a nemi Log in USB receiver mode).
- Click Connect COM-Port, set radio data rate, number of nodes and channel matching the module, and select the module type nemi G+ ultra nano.
- Select sampling rate, measuring range and active axes, then click Start Receiver.
- Switch on the module without connected USB cable. Live data appears within a few seconds. At rest, the axis aligned with gravity reads approximately 1 g.
- Check signal strength and latency, verify the spectrum in the FFT view and record a short CSV file before final integration.
With nemi Log or nemi EdgeBase as standalone receivers, the module pairs automatically when channel and radio mode match. On the nemi EdgeBase, the module is configured like the nemi G+ ultra (sensor_type: ultra_vibration, see nemi G+ ultra).
LED Status Codes¶
The LEDs are located on the board.
| LED pattern | Meaning |
|---|---|
| Rapid flash: white → green → red → blue | Sensor restart |
| Solid red | Battery charging via USB or wide-range voltage input |
| Red no longer continuously lit | Battery fully charged |
| Solid green + flashing yellow | USB data connection detected; waiting for COM port to open |
| Solid green + flashing blue | COM port open; waiting for RF parameters or settings |
| Regular short red flashes (~2 s) | Actively sampling and transmitting measurement data |
| Short green flashes every 10 s (~1 s) | Sleep mode |
| Regular short blue flashes (~1 s) | Time synchronization with the wireless network |
| Green LED on temporarily or continuously (in wireless mode) | Internal ring buffer 80 % full — data cannot be transmitted fast enough; risk of data loss |
Mounting & Connections¶
Mechanical Mounting¶
nemi G+ ultra nano can be mounted in three ways. All options use the same aluminum baseplate (33 × 33 mm) to which the board is screwed. The baseplate is not included as standard and can be ordered additionally.

| Option | Description |
|---|---|
| Baseplate | Optional, can be ordered additionally. The baseplate is screwed (M4 thread in the center) or glued to the measuring object. Best vibration transmission with a grub screw connection. Using the baseplate is recommended because of the THT connections protruding from the bottom of the board. |
| Baseplate with cover | Compact cover (33.2 × 33.2 × 14.6 mm, 16.5 mm including terminal block) protects the electronics. Terminal block, slide switch and micro-USB remain accessible; sensor axes and measuring range are marked on the cover. |
| Waterproof housing | 3D-printed housing (33 × 33 × 19.4 mm) on the baseplate, potted with resin. Charging and radio configuration via a magnetic USB connector, so the housing does not have to be opened. |
| Baseplate dimensions | Cover and waterproof housing dimensions |
|---|---|
![]() |
![]() |
(All dimensions in mm)
Vibration transmission: At high frequencies, the stiffness of the mounting dominates the measured frequency response. Couple the baseplate rigidly to the structure; soft mounts, thick adhesive layers or gaskets attenuate high-frequency content.
Axis orientation: Document the orientation of the X, Y and Z axes relative to the measuring object before final assembly.
Antenna and enclosures: nemi G+ ultra nano has a u.FL connector for an external 2.4 GHz / 50 Ω antenna. No antenna is included as standard; i4M supplies approved antennas on request. Only antennas approved by i4M may be used — please ask i4M for approved antennas. Metal enclosures strongly attenuate 2.4 GHz radio signals: use non-metallic enclosures or radio windows, or route an external antenna to the outside of a metal enclosure (e.g. u.FL-to-RP-SMA cable → panel connector → antenna). Secure the u.FL plug mechanically in vibrating or rotating installations and validate the range in the final installation.
Pin Assignment¶

| Pin | Function |
|---|---|
| GND | Ground |
| BAT | Battery 3.3 – 5 V |
| RES | Reserved |
| DCIN | DC input 5 – 30 V |
| Connection | Function |
|---|---|
| Micro-USB | Charging, power supply (5 V), radio configuration |
| Slide switch | Top = powered by BAT, bottom = powered by DCIN |
| Solder jumpers | Both closed = charger active (default) |
Power Supply Configuration¶
By default, nemi G+ ultra nano is powered by a rechargeable Li-ion battery on the BAT pin. Optionally — set with the solder jumpers to avoid charging primary cells — a single non-rechargeable lithium battery (Li-SOCl₂) or 3 alkaline batteries in series can be used. The DCIN input (5 – 30 V DC) is available with every power option. The micro-USB connector can also be used as power supply (5 V).
| Powered by BAT pin (slide switch top) | Powered by DCIN pin (slide switch bottom) |
|---|---|
![]() |
![]() |
| e.g. rechargeable Li-ion battery (must have its own protection circuit), non-rechargeable lithium battery or other DC supply 3.3 – 5 V | e.g. 24 V DC, 2 – 8 non-rechargeable lithium batteries in series or a 12 V lead-acid battery |
Solder jumpers (top side of the board):

| Power option | Solder jumpers and function |
|---|---|
| Rechargeable battery (default) | Closed: The BAT pin is connected to the charger IC; the battery is charged via USB (constant current – constant voltage, 4.2 V, 120 mA). The battery voltage is measured. |
| Non-rechargeable battery | Open: The BAT pin is NOT connected to the charger IC (prevents charging a primary cell). The battery voltage is measured. Input range 3.3 – 5 V. |
Check the solder jumpers before connecting a battery
Never connect a non-rechargeable battery while the solder jumpers are closed.
External Sensors¶
nemi G+ ultra nano has no external sensor inputs. For analog sensors, strain gauges or other transducers, use the nemi DAQ or nemi DAQ nano.
Detailed Configuration¶
Configuration is split into two layers:
- Persistent radio settings — written with nemi Sensor Config over micro-USB (channel, radio mode, node number, max. nodes).
- Runtime measurement settings — set wirelessly via nemi Studio, the nemi Studio Web App, nemi EdgeBase YAML files or nemi Log configuration CSVs (sampling rate, range, active axes, IMU ranges, sensor mode).
nemi G+ ultra nano uses the same firmware, settings and data message as the nemi G+ ultra. See the nemi G+ ultra page for the configuration tools reference and decoding details.
Sampling Rate, Axes and Node Count¶
| Sampling rate | −3 dB bandwidth | Active axes per sensor | Max. sensors on one channel | Node count setting |
|---|---|---|---|---|
| 26.666 kHz | 6.72 kHz | 1 | 1 | 1 (low latency) |
| 13.333 kHz | 4.66 kHz | 2 | 1 | 1 (low latency) |
| 13.333 kHz | 4.66 kHz | 1 | 3 | 3 |
| 6.666 kHz | 2.35 kHz | 3 | 1 | 1 (low latency) |
| 6.666 kHz | 2.35 kHz | 2 | 3 | 3 |
| 3.333 kHz | 1.17 kHz | 3 | 3 | 3 |
| 3.333 kHz | 1.17 kHz | 1 | 8 | 8 |
Values for 2 Mbit/s with a radio channel load below 70 % (rated good by the nemi Link 2400 Radio Channel Calculator). 13.333 kHz with all three axes reaches approx. 100 % even in 1-node mode and is therefore not recommended; 6.666 kHz with three axes on three sensors is marginal (approx. 84 %).
Disabling unused axes reduces radio load and power consumption. Verify the planned configuration with the nemi Link 2400 Radio Channel Calculator.
Measuring Range¶
Always select the smallest range that avoids clipping.
| Range | Resolution | Conversion factor |
|---|---|---|
| ± 2 g | 61 µg/LSB | 16,393.44 LSB/g |
| ± 4 g | 122 µg/LSB | 8,196.72 LSB/g |
| ± 8 g | 244 µg/LSB | 4,098.36 LSB/g |
| ± 16 g | 488 µg/LSB | 2,049.18 LSB/g |
Sensor Mode¶
| Mode | Behavior |
|---|---|
| 0 — Sleep | Sensor sleeps and wakes up periodically to receive new settings |
| 1 — Continuous | Continuous sampling and transmission |
| 2 — Intermittent | Measures for Sample [s], then sleeps for Sleep [s] |
Power Consumption and Runtime¶
Average current consumption on the BAT pin at 3.3 V:
| Sampling rate | Active axes | Current | Power |
|---|---|---|---|
| 26,667 Hz | X | 19.2 mA | ≈ 63 mW |
| 13,333 Hz | X, Y | 18.5 mA | ≈ 61 mW |
| 6,666 Hz | X, Y, Z | 15.1 mA | ≈ 50 mW |
| 3,333 Hz | X, Y, Z | 10.3 mA | 34 mW |
Power supply examples and expected runtime (3,333 Hz, all axes, ACC / GYR / MAG active, radio mode 2 Mbit/s):
| Power source | Connected to | Nominal capacity [Wh] | Efficiency at nominal voltage | Effective capacity [Wh] | Projected runtime [days] |
|---|---|---|---|---|---|
| 1 × Saft LS 14250 | GND and BAT | 4.3 | ~89 % (3.6 V) | 3.8 | 5 |
| 1 × Saft LS 33600 | GND and BAT | 61.2 | ~89 % (3.6 V) | 54.5 | 67 |
| 2 × Saft LS 33600 in series | GND and DCIN | 122.4 | ~85 % (7.2 V) | 104 | 127 |
| 4 × Saft LS 33600 in series | GND and DCIN | 244.8 | ~81 % (14.4 V) | 198 | 243 |
The runtime is calculated from the nominal battery capacity. The usable capacity depends on temperature, discharge rate and other environmental factors. For Saft Li-SOCl₂ batteries, the voltage can drop below 3.3 V at temperatures below 0 °C; a single-battery configuration is therefore not recommended below 0 °C.
Power source examples:
| Type | Example | Nominal voltage [V] | Capacity [Wh] | Dimensions [mm] |
|---|---|---|---|---|
| Rechargeable (LiPo) | Renata ICP641620PA | 3.7 | 0.6 | 7 × 16 × 22 |
| Rechargeable | Panasonic NCR18650B | 3.7 | 12.6 | Ø 18 × 69 |
| Non-rechargeable (Li-SOCl₂) | Saft LS14250 | 3.6 | 4.3 | Ø 14 × 25 |
| Non-rechargeable (Li-SOCl₂) | Saft LS33600 | 3.6 | 61 | Ø 33 × 61 |
| Non-rechargeable (lithium primary) | Varta 9 V battery | 9 | 10.8 | 26 × 49 × 16 |
| Non-rechargeable (alkaline primary) | Varta Industrial Pro 4020 D Mono (3 in series) | 4.5 | 76.5 | 3 × Ø 34.2 × 61.5 |
Time Synchronization¶
Within one nemi Link 2400 network, the module clock is synchronized to the receiver with an accuracy of ±10 µs with a stable radio connection. With a poor radio connection, some synchronization events have to be discarded because their transit time is too long. The receiver handles its own downstream synchronization (nemi Connect: host computer clock; nemi Log: RTC or GNSS; nemi EdgeBase: NTP or GNSS).
Integration¶
nemi G+ ultra nano communicates only via nemi Link 2400 radio to a receiver; all external integration happens at the receiver level. Integration paths, data formats and decoding are identical to the nemi G+ ultra.
| Receiver | Best for | Data access |
|---|---|---|
| nemi Connect | PC-based live testing with nemi Studio / nemi Studio Web App, CSV recording, Python API, Gantner Q.Station | USB virtual COM port |
| nemi Log | Compact standalone logging; alternatively USB receiver for nemi Studio, like nemi Connect | .bin files with Python decoder |
| nemi EdgeBase | Long-term field monitoring, MQTT, FTP, LTE/VPN, edge computing | .bin.bz2 files via FTP, MQTT(S), live TCP stream (logging_mode 6) |
Key points for custom integrations:
- The module transmits the same data message as the nemi G+ ultra. Parsers for the standard nemi G+ data message cannot decode it.
- Only active axes are included in the payload, in X, Y, Z order.
- The receiver firmware must support the nemi G+ ultra data format. nemi Connect units delivered together with the module are pre-flashed.
- Via MQTT on the nemi EdgeBase, the module sends like a nemi G+ (same streams, channels and trigger indices);
<sensor>in the topic is itsfile_identifier, which also identifies it in the logged file names.
The complete USB data message protocol documentation is provided to customers on request — i4M discloses the protocol to its customers.
Troubleshooting¶
| Symptom | Likely cause | Resolution |
|---|---|---|
| Module does not start | Slide switch in wrong position for the connected source; supply out of range | Top = BAT, bottom = DCIN; check voltage (BAT 3.3 – 5 V, DCIN 5 – 30 V) |
| Battery is not charged via USB | Solder jumpers open | Close both solder jumpers — only for rechargeable Li-ion batteries with protection circuit |
| Primary battery heats up or swells | Solder jumpers closed (charger active) with a non-rechargeable battery | Disconnect immediately; open both solder jumpers before reconnecting |
| Short runtime with Li-SOCl₂ cell at low temperatures | Cell voltage drops below 3.3 V below 0 °C | Use two or more cells in series on DCIN |
| Dropped samples at 26.666 kHz | More than one axis active or additional nodes on the channel | Use 1-node mode, one active axis, no other sensor on the channel |
| No data after configuration | Channel, radio mode or node number mismatch | Reconfigure via nemi Sensor Config; match settings on sensor and receiver |
| Data garbled or absent with an older nemi Connect | Receiver firmware without nemi G+ ultra support | Update the nemi Connect firmware; contact i4M support |
| Poor radio range in the final installation | Metal enclosure or structure shields the antenna; loose u.FL connection | Use a non-metallic enclosure or radio window, or route an external antenna (u.FL) to the outside; check the u.FL seating; validate range on site |
| Intermittent reception | 2.4 GHz interference or weak signal | Change the radio channel, improve antenna placement, reduce distance and obstructions |
| Gaps in a multi-node setup | Node count on the receiver does not match the network | Set the same node count on receiver and sensors |
| USB connected but no COM port appears | Charge-only USB cable | Use a data-capable micro-USB cable |
Product Changes¶
Hardware Revision¶
This documentation applies to hardware revision 1.2 and later (power terminal with GND / BAT / RES / DCIN, slide switch for BAT / DCIN, solder jumpers for charger configuration). For earlier revisions contact i4M support.
Ordering Options¶
| Option | Description |
|---|---|
| nemi G+ ultra nano | Board with micro-USB socket and terminal block |
| Without USB socket and terminal block | For very flat installation spaces. Radio parameters are fixed and the power supply is connected via soldered wires. State the radio settings with your order. |
| Baseplate, baseplate with cover, waterproof housing | Can be ordered additionally; see Mounting & Connections |
Related Products¶
| Product | Difference |
|---|---|
| nemi G+ ultra | Same electronics in a housing with integrated rechargeable battery |
| nemi G+ nano | OEM board with 20-bit main sensor, lower noise, up to 4,000 Hz — preferred for tilt and low-frequency measurements |
Software Tools Version Reference¶
| Tool | Version reference |
|---|---|
| nemi Sensor Config | 2.1 (as of March 2024) |
| nemi Studio | 1.1 (as of November 2026) |
| nemi Studio Web App | 2026.11.04.3 (as of November 2026) |
| wirelessSensorPlot (legacy, no longer maintained) | 7.4 b3 or later required for nemi G+ ultra nano |
FAQ¶
Applications¶
What is the difference between nemi G+ ultra nano and nemi G+ ultra? The measurement electronics, firmware and data format are identical. The nano is a 30 × 30 mm board for integration into custom enclosures and is powered via external batteries or DC supply; the nemi G+ ultra is a housed sensor with integrated rechargeable battery.
Can I build a waterproof sensor with nemi G+ ultra nano? Yes. A potted waterproof housing (33 × 33 × 19.4 mm) with magnetic USB connector is available. For own enclosures, use non-metallic materials so the 2.4 GHz radio signal is not shielded, or connect an external antenna via the u.FL connector.
Is nemi G+ ultra nano suitable for tilt measurements? For high-precision tilt measurements, the nemi G+ nano is recommended because of its higher resolution and lower noise.
Which standards can be met? The bandwidth requirements of ISO/DIN ISO 20816 and DIN ISO 2954 are met even at the lowest sampling rate (3.333 kHz, 1.17 kHz bandwidth).
Power Supply¶
Which batteries can I use? Rechargeable Li-ion batteries with their own protection circuit (solder jumpers closed, default), or non-rechargeable lithium or alkaline batteries (solder jumpers open) on the BAT pin (3.3 – 5 V). Higher-voltage sources (5 – 30 V), e.g. several primary cells in series, 12 V lead-acid batteries or 24 V DC, are connected to DCIN.
How long does the module run on a battery? At 3,333 Hz with all axes active (10.3 mA at 3.3 V), e.g. approx. 67 days with one Saft LS 33600 and approx. 243 days with four Saft LS 33600 in series. See Power Consumption and Runtime.
Can I use a single Li-SOCl₂ cell below 0 °C? Not recommended. The cell voltage can drop below 3.3 V at low temperatures. Use two or more cells in series on DCIN.
Sampling and Radio¶
Can I use all three axes at 26.666 kHz? No. At 26.666 kHz only one axis can be active, and only one sensor can use the channel (1-node mode). At 13.333 kHz two axes are possible with one sensor, or one active axis each with up to three sensors; at 6.666 kHz all axes with one sensor or two axes with three sensors; at 3.333 kHz all axes with three sensors or one axis with up to eight sensors (all at 2 Mbit/s).
What happens if the radio link is interrupted? Data is buffered in the module and transmitted after the link is restored. Interruptions of up to several minutes are bridged without lost samples.
What range can I expect? Up to approx. 125 m (urban / line of sight) in the 1 Mbit/s mode, which is the longest-range mode for regular use. The 500 kbit/s mode may be possible in single-sensor mode; the 125 kbit/s mode is not usable. Validate the range in the final installation, especially inside enclosures.
Integration and Software¶
Does the nano require different software than nemi G+ ultra? No. Select the module type nemi G+ ultra nano in nemi Studio or the nemi Studio Web App; configuration and data format are identical.
Can I use an older nemi Connect? Only after a firmware update that supports the nemi G+ ultra data format. Contact i4M support.
Can nemi G+ ultra nano be installed inside a metal enclosure? Yes, with an external 2.4 GHz / 50 Ω antenna connected to the u.FL connector and routed to the outside of the enclosure. Validate the range in the final installation.
How accurate is timing between sensor nodes? Within one nemi Link 2400 network, sensor clocks are synchronized to the receiver with ±10 µs accuracy with a stable radio connection.
Can the radio settings be changed without a USB socket? No. In the ordering option without USB socket and terminal block, the radio parameters are fixed at the factory. State the required radio settings with your order.